6.4.1 Required clearance distances
Observe the required clearance distances.
1
3
2
Fig. 6.3 required clearance distances
[1] Minimum clearance of 50 mm between the worktop cut-out
and the rear edge of the worktop.
[2] Minimum clearance of 300 mm from the left and right of the
worktop cut-out to the adjacent cabinet or wall.
[3] Minimum clearance of 600 mm between the worktop
and the wall unit. A minimum clearance of 1000 mm is
recommended for ergonomic reasons.
6.4.2 General kitchen unit specifications
Cross bars on the kitchen unit in the area of the
worktop cut-out may need to be removed.
In the case of thin worktops, there must be a
sufficiently rigid support plate on the unit.
No false floor is necessary below the cooktop. If cable
protection (false floor) is planned, the following must
be taken into account:
It must be fitted in such a way that it can be
removed for maintenance work.
To ensure sufficient cooktop ventilation, a minimum
distance of 15 mm to the bottom edge of the
cooktop is to be observed.
The drawers and/or shelves in the floor unit must be
removable.
For correct installation, the slide-in units of the
base cabinet must be shortened depending on the
installation situation.
6.1.2 Home In module PUHIM (optional)
Via this additional interface it is possible to establish a
connection to other systems and, for example, a window
contact switch or low pressure warning device can be
connected. The module is to be integrated in the cooktop.
INFO The BORA Pure Home In module PUHIM is
available as an accessory (including installation
instructions).
INFO The BORA window contact switch UFKS is
available as an accessory (including installation
instructions).
6.2 Scope of delivery
Scope of delivery: PUXA, PUXU, PURA, PURU Quantity
Cooktop with integrated cooktop extractor 1
Air inlet nozzle 1
Stainless steel grease filter 1
Operating and installation instructions 1
Installation clamps 4
Sealing tape 1
Height adjustment plate set 1
Glass ceramic scraper 1
Bag containing various small parts for assembly 1
Additional scope of delivery: PURU, PUXU
Activated charcoal filter 1
Template for back wall cut-out 1
Tab. 6.1 Scope of delivery
6.2.1 Checking the scope of delivery
Make sure the delivery is complete and check it for
damage.
If there are any missing or damaged parts, please
notify BORA After Sales Service immediately.
Do not under any circumstances install parts which are
damaged.
Dispose of transport packaging in the proper manner
(see the Decommissioning, disassembly and disposal
section).
6.3 Tool and aids
The following special tools are required to correctly install
the cooktop:
Compass saw or hand saw
Drilling template for cut-out on rear wall PURU
(included in scope of delivery)
Torx 20 screwdriver
Black, heat-resistant silicone sealant