Measurement Guide

Technical Evaluation Report (TER)
TER No. 1312-03 Page 7 of 9
Versetta Stone
®
Panelized Stone Veneer
Applications Using Continuous Insulation
Over Concrete or Masonry Walls
Copyright © 2018
7.3. Reports showing compliance with ASTM D3679, Annex 1 for Pressure Equalization.
7.4. Reports of transverse wind load testing in accordance with ASTM D5206, Procedure B.
7.5. Reports showing compliance with ASTM E84 for surface burning.
7.6. Report showing compliance with ASTM E2273 for water drainage efficiency.
7.7. Fastening Systems for Continuous Insulation, Final Report 10-11; New York State Energy Research and
Development Authority (NYSERDA); Albany, NY; April 2010.
7.8. Baker, P. and Lepage, R.; Cladding Attachment Over Thick Exterior Insulating Sheathing; Prepared by the
Building Science Corporation for the National Renewable Energy Laboratory on behalf of the U.S. Department
of Energy’s Building America Program; January 2014.
7.9. Baker, P.; Initial and Long-Term Movement of Cladding Installed Over Exterior Rigid Insulation; Prepared by
the Building Science Corporation for the National Renewable Energy Laboratory on behalf of the U.S.
Department of Energy’s Building America Program; September, 2014.
7.10. Report showing compliance with required quality control procedures and documentation.
7.11. The product(s) evaluated by this TER fall within the scope of one or more of the model, state or local building
codes for building construction. The testing and/or substantiating data used in this TER is limited to buildings,
structures, building elements, construction materials and civil engineering related specifically to buildings.
7.12. The provisions of model, state or local building codes for building construction do not intend to prevent the
installation of any material or to prohibit any design or method of construction. Alternatives shall use consensus
standards, performance-based design methods or other engineering mechanics based means of compliance.
This TER assesses compliance with defined standards, accepted engineering analysis, performance-based
design methods, etc. in the context of the pertinent building code requirements.
7.13. Some information contained herein is the result of testing and/or data analysis by other sources, which DrJ
relies on to be accurate, as it undertakes its engineering analysis.
7.14. DrJ has reviewed and found the data provided by other professional sources are credible. The information in
this TER conforms with DrJ’s procedure for acceptance of data from approved sources.
7.15. DrJ’s responsibility for data provided by approved sources conforms with IBC Section 1703 and any relevant
professional engineering law.
7.16. Where appropriate, DrJ relies on the derivation of design values, which have been codified into law through
codes and standards (e.g., IRC, WFCM, IBC, SDPWS, NDS, ACI, AISI, PS-20, PS-2, etc.). This includes
review of code provisions and any related test data that aids in comparative analysis or provides support for
equivalency to an intended end-use application. Where the accuracy of design values provided herein is reliant
upon the published properties of commodity materials (e.g. lumber, steel, concrete, etc), DrJ relies upon
grade/properties provided by the raw material supplier to be accurate and conforming to the mechanical
properties defined in the relevant material standard.
8. Findings:
8.1. Versetta Stone
®
is a suitable alternative to the products listed in the applicable building code for use as an
exterior wall covering in accordance with IBC Section 1404.10 and the IRC Section R703.10.
8.2. Versetta Stone
®
is suitable for use as an exterior wall covering assembly when installed over concrete and
masonry walls separately capable of resisting 100% of the design wind pressures. An intervening layer(s) of
continuous insulation may be installed between the Versetta Stone
®
and the sheathing in accordance with
Table 1-2.
8.3. IBC Section 104.11 (IRC Section R104.11 and IFC Section 104.9 are similar) states:
104.11 Alternative materials, design and methods of construction and equipment. The provisions of this code are
not intended to prevent the installation of any material or to prohibit any design or method of construction not specifically
prescribed by this code, provided that any such alternative has been approved. An alternative material, design or method
of construction shall be approved where the building official finds that the proposed design is satisfactory and complies
with the intent of the provisions of this code, and that the material, method or work offered is, for the purpose intended,
not less than the equivalent of that prescribed in this code. Where the alternative material, design or method of