Greenstar Highflow 440 FLOOR STANDING RSF GAS-FIRED COMBINATION BOILER FOR SEALED CENTRAL HEATING SYSTEMS AND MAINS FED DOMESTIC HOT WATER THIS APPLIANCE IS FOR USE WITH NATURAL GAS OR LPG (Cat II 2H3P TYPE C13 & C33) NATURAL GAS: 47 311 82 LIQUID PETROLEUM GAS: 47 311 83 GB/IE USER INSTRUCTIONS & CUSTOMER CARE GUIDE
USER INSTRUCTIONS & CUSTOMER CARE GUIDE CONTACT INFORMATION WORCESTER BOSCH: PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE OPERATING YOUR APPLIANCE TECHNICAL: 08705 266241 SERVICE: 08547 256206 SPARES: 01905 752571 LITERATURE: 01905 752556 TRAINING: 01905 752526 SALES: 01905 752640 WEBSITE: www.worcester-bosch.co.uk WATER TREATMENT: FERNOX 01799 550811 www.fernox.com SENTINEL 0151 420 9595 www.betzdearborn.
USING YOUR APPLIANCE CONTROLS OPERATING THE APPLIANCE Switching the appliance on/off Setting the central heating temperature Controlling central heating Setting the hot water temperature Summer mode, hot water only Frost protection Fault condition 8 8 8 9 10 10 10 ENERGY SAVING TIPS ON ENERGY SAVING 11 MAINTENANCE MAINTAINING YOUR APPLIANCE FAULT FINDING FAULT OR BREAKDOWN 14 15 16 GUARANTEE YOUR GUARANTEE GUARANTEE REGISTRATION 17 18 WORCESTER BOSCH GREENSTAR HIGHFLOW 440 6 720 611 731a (08.
INTRODUCTION EXCELLENCE COMES AS STANDARD Thank you for purchasing a Greenstar Highflow 440 gas-fired condensing boiler manufactured by Worcester Bosch. The company prides itself on manufacturing boilers to the strictest quality control standards throughout every stage of production. Worcester Bosch has led the field in innovative appliance design and performance for more than 40 years This heritage means all products are of exceptional quality and proven reliability.
IF YOU SMELL GAS: COMBUSTIBLE AND CORROSIVE MATERIALS DO NOT operate any electrical switches Do not store or use any combustible materials (paper, thinners, paints etc.
INTRODUCTION GENERAL NOTES To get the best from your appliance please read these instructions carefully SEALED HEATING SYSTEMS The appliance is fitted to a sealed heating system which is pressurised. Your installer will tell you of the minimum and maximum pressure which must be indicated on the pressure gauge. Check regularly that the pressure is maintained and contact your installer or maintenance engineer if there is a permanent significant drop in pressure.
HOT AND COLD FLOW PUMP The flow of water demanded from both hot and cold service outlets is dependent on the mains supply, it may not be possible in some installations to operate all outlets simultaneously. The pump is set by the manufacturer and must not be adjusted. WATER MAINS FAILURE If there is a failure of the mains water supply then no water will be available at a tap or shower until the mains supply is restored. The appliance will still operate in the central heating mode.
INTRODUCTION GENERAL NOTES Fig. a. BOILER LOCATION AND CLEARANCES This boiler is only suitable for installing internally within a property at a suitable location onto a fixed, rigid non-combustable surface at least the same size of the boiler and capable of supporting the boiler weight. Compartments: Follow the requirements of BS6798 and BS5440 Part 2 and note: Minimum clearances must be maintained. Fig. b. An access door is required for servicing and maintenance of the boiler.
CONTROLS 2 3 9 8 4 5 6 7 10 1. INDICATOR LAMP FOR “OFF/ON” 2. “INSTALLER SERVICE FUNCTION” BUTTON (For use only by service engineer) 3. RESET BUTTON 4. DISPLAY 5. SERVICE BUTTON 6. “ECO” MODE INDICATOR 7. INDICATOR LAMP FOR “BURNER ON” 8. MASTER SWITCH 9. CENTRAL HEATING TEMPERATURE CONTROL USING YOUR APPLIANCE 1 10. HOT WATER TEMPERATURE CONTROL 2. PU 11. SYSTEM PRESSURE GAUGE 12. FILLING LOOP CONNECTION LL 1.
OPERATING THE APPLIANCE SWITCHING THE APPLIANCE ON/OFF Switching on Switch on the appliance at the master switch (I). USING YOUR APPLIANCE The indicator lamp shows green and the display will show the central heating flow temperature, when the appliance is operating in the central heating mode. Note: If the display alternates between -II- & the central heating flow temperature, the condensate trap filling programme is active. If the display shows “t” the tank heat up programme is running.
OPERATING THE APPLIANCE SETTING THE HOT WATER TEMPERATURE The hot water temperature can be set to between approx. 45°C and 65°C using the temperature control The domestic hot water temperature is not shown on the display. Control Setting Water Temperature Anti-clockwise limit approx. 45°C ● approx. 58°C Clockwise limit approx.
OPERATING THE APPLIANCE SUMMER MODE, HOT WATER ONLY With room temperature controller fitted USING YOUR APPLIANCE Turn temperature control on the appliance anti-clockwise as far as the stop. The central heating is now turned off. The hot water function and the power supply for the programmer and thermostat remain switched on. FROST PROTECTION Leave master switch switched on. If the temperature falls to 5°C the boiler will fire to avoid the possibility of freezing.
TIPS ON ENERGY SAVING The boiler is designed to provide a high level of comfort while keeping gas consumption and the resulting environmental effect as low as possible. The gas supply to the burner is controlled according to the level of demand for heat. The boiler continues to operate with a low flame if the demand for heat reduces. The technical term for this process is modulating control. Modulating control reduces temperature fluctuations and provides even distribution of heat throughout the home.
TIPS ON ENERGY SAVING Roof insulation Around 30% of the heat loss from a property is through the roof. Replace any old insulation with new insulation, preferably of around 200mm thickness or more. Window frames Single glazed windows, particularly those with steel frames, can lose a great deal of heat. Consideration should be given to replacement with PVCu or wooden framed double glazed units. ENERGY SAVING Curtains Lined curtains, or heavier full length curtains can provide excellent insulation.
TIPS ON ENERGY SAVING Radiators It is advisable to manually adjust all radiator valves every 2-3 months to prevent them from sticking. It is also important that the plastic tops of all valves are always in position and not cracked or damaged so as to prevent accidents. Care should be taken when vacuum cleaning carpets so as to avoid damage to valves and pipework.
MAINTAINING YOUR APPLIANCE Your new Greenstar Highflow 440 gas-fired appliance represents a long term investment in a reliable, high quality product. In order to realise its maximum working life, and to ensure it continues to operate at peak efficiency and performance, it is essential that your boiler receives regular, servicing and maintenance checks from a competent person beyond the initial 2 year guarantee period.
Problem Cause Remedy Desired room temperature is not reached Thermostatic radiator valve(s) set too low Increase thermostatic radiator valve setting(s) Temperature control for CH flow on boiler set too low Increase CH flow temperature control setting Air trapped in heating system Bleed radiators and recharge heating system Desired room temperature exceeded by large amount Radiators are too hot Turn down thermostatic radiator valves / room stat Temperature rises instead of falling Clock is inco
FAULT OR BREAKDOWN This appliance is supported in the UK by Worcester Heat Systems Ltd. - part of the Bosch Group. Specialist factory trained Service Engineers are available to attend a breakdown occurring on this appliance. No charge will be made for parts and/or labour providing: An appliance fault is found and the appliance has been installed within the past 24 months. Reasonable evidence of this must be supplied on request.
YOUR GUARANTEE This appliance is guaranteed against faulty material or workmanship for a period of 24 calendar months from the date of installation subject to the following terms and conditions. During the period of this guarantee any components of the unit which are proven to be faulty or defective in manufacture will be exchanged or repaired free of charge by Worcester Heat Systems Ltd.
GUARANTEE REGISTRATION You should complete and return the postpaid Guarantee Registration Card within 14 days of purchase. Returning the card will register you as the owner of your new Greenstar Highflow 440 appliance and will assist us in maintaining an effective and efficient customer service by establishing a reference and permanent record for your boiler. This does not affect your statutory rights. For your own record: Model Serial No.
USER INSTRUCTIONS & CUSTOMER CARE GUIDE EXCELLENCE COMES AS STANDARD Worcester Heat Systems Ltd (Bosch Group) Cotswold Way, Warndon, Worcester WR4 9SW. Tel. 01905 754624 Fax. 01905 754619 www.worcester-bosch.co.uk 6 720 611 731a (08.