Solution 64 ���������������� EN User Guide Security System
Solution 64 User Guide Co py r i g ht N o t i ce Telepermit Note Unless otherwise indicated, this publication is the copyright of Bosch Security Systems Pty Ltd (“Bosch”). All rights are reserved.You may download a single copy of this publication.
Solution 64 User Guide Contents Copyright Notice ......................................................... 2 Trademarks .................................................................. 2 Notice of Liability ........................................................ 2 Notice to Owner ......................................................... 2 Telepermit Note .......................................................... 2 Contents ...........................................................................
Solution 64 User Guide Pro gra m M e n u Tree Table 1: shows all of the system options in a tabular format. Each option can be access by pressing the Menu key and then drilling down using the arrow and OK keys until the required option is listed on the display. A quick way to jump to a particular option is to press the Menu key followed by the specific option number. You may be asked to enter your PIN when accessing some options.
Solution 64 User Guide I nt ro d u c t i o n Your system helps to secure life, property and investments against fire, theft and bodily harm. It consists of a keypad (or keypads), sensors such as motion detectors or devices located on doors and windows, and other sensing devices designed to detect the presence of smoke or combustion. The location and quantity of sensing devices will have already been discussed with you by your alarm installer.
Solution 64 User Guide Re p o r t i n g Al a r m s Key Description Your system may be programmed to send reports to your security company. Once the report is complete, the system returns the telephone to normal operation (check with your security company). The [] key allows you to navigate through menus or to toggle characters when programming telephone numbers. Pressing The [] key will display current trouble conditions when the area that the keypad is displaying is disarmed.
Solution 64 User Guide Icon Status Red LED On The area is turned off. Off The area is turned All On or Part On On The area is turned All On Off The area is turned Off On You have mail waiting to be read Off No Mail On Area is ready to turn on (All On / Part On) Off Not ready, Zone Open On All On Flashing Alarm On Green LED Red & Green LED Meaning Exit Delay Tone After you turn an area All On, the keypad will sound 1 short beep every second.
Solution 64 User Guide Ba s i c Sys te m O p eration Turning An Area All On Use this function to turn an area All On. The Solution 64 control panel is factory default only for one area. As soon as you turn an area on, exit time will start. Exit time allows you to exit the premises without sounding an alarm. Your security company programs the length of exit delay time. 1. Make sure that all zones are normal (not faulted). 2. Enter your PIN, then press the [ON] key.
Solution 64 User Guide Remote Arming - Quick Arm If you forget to arm your system it may be possible for you to remotely arm it using a touch tone telephone if the remote arm option has been enabled by your installer. To arm the system call the number which the panel is connected to and when the panel answer you will here 3 beeps in accending frequency if the panel is in the disarmed condition. Press [0] + [#] to arm. You will hear 3 beeps in decending order when the panel arms.
Solution 64 User Guide to add, then press [OK]. The keypad will prompt you to enter the new pin. Access > PIN Codes > Change Other PIN MENU 1-1-1 Enter New PIN for User 3 Name U003 If you have a master PIN, this command allows you to change somebody else’s PIN. It is recommended that you write down the old PIN and the new one before you begin. Once the change is complete you should destroy the written copy. The new PIN must have the same number of digits as the old PIN.
Solution 64 User Guide Tokens This section outlines how to add and delete token cards that allow an alternate method for users to turn the system on and off via a prox reader enabled Keypad or an external reader. The system can also be configured to automaticall open a door if it has been fitted with an electric door lock. You should discuss this feature with your installer for more details on your particular installation. 1. Enter [MENU] + [1] + [2] + [1]. A list of users will display on the keypad. 2.
Solution 64 User Guide 2. Use the [↑] and [↓] keys to select the user that you want to add the RF keyfob ID, then press [OK] to select. Alternatively, you can enter the user number you, then press [OK]. 2. The keypad will prompt you to enter the RF keyfob ID number: The keypad will display the current user name. Enter keyfob RFid for U016 User 16 Name 000000000 Press OK or MENU User Name U001 User 1 Name Press ◄► OK to SAVE 3. Enter the RF Keyfob ID Number 4.
Solution 64 User Guide time group to specify the access period, day of the week and holidays. To now restrict the user, they must belong also to the same timer group. This now restricts the user from accessing the system outside the nominated times and days within the schedules linked to the timer group. User Can only belong to 1 timer group. Schedules Multiple schedules can be linked to the same timer group.
Solution 64 User Guide Main Office A001 Disarmed Area 1 Name EXIT NOW Press OK or MENU If the area is turned All On, the keypad will display: Main Office A001 Armed All On When exit time has expired, the keypad will display that all areas are turned All On (Armed). Area 1 Name ARMED If the area is turned Part On, the keypad will display: Fri,Aug,13 5:34 pm Main Office A001 Armed Part On i 3. Note To exit, press [OK]. Area icons will only display if programmed to do so by your security installer.
Solution 64 User Guide Areas > Commands > Chime On/Off MENU 2-0-5 Chime mode allows you to monitor a zone (or group of zones) to sound the keypad buzzer or activate a programmable output when the corresponding area is turned off (disarmed). This can be useful when you need to monitor the front or back entrance to the premises. This menu allows a user to turn chime mode on or off. Only keypads programmed to sound the chime tone will be heard when a zone programmed for chime is faulted.
Solution 64 User Guide Inputs > Commands > Bypass Zones MENU 3-0-2 This menu allows you to bypass or un-bypass a single or multiple zones before you turn the area All On, Part On or Part 2 On. When bypassing zones, it disables the ability for a zone to detect intrusion and sound an alarm. A burglary zone will automatically become un-bypassed when you turn the corresponding area off (disarm). Any 24-Hr fire or 24-Hr non fire zones will need to be manually un-bypassed.
Solution 64 User Guide Inputs > Commands > Inputs > Commands > Set Part 2 Zones MENU 3-0-4 This menu allows you to program which zones are to be monitored when an area has been turned Part 2 On. Enter programming mode (PIN + MENU) then, Smoke Sensor Reset This menu allows you to reset smoke sensors. Enter programming mode (PIN + MENU) then, 1. 1. Enter [MENU] + [3] + [0] + [4]. A list of areas will display on the keypad. 2.
Solution 64 User Guide Inputs > Input Testing > Walk Test All Zones Inputs > Input Testing > MENU 3-9-0 This menu allows you to test all zones within an area at the same time. To successfully walk test each zone, you must open and close each zone. Enter programming mode (PIN + MENU) then, Walk Test A Single Zone This menu allows you to select a single zone to be tested via walk test. Enter programming mode (PIN + MENU) then, 1. 1. Press [MENU] + [3] + [9] + [0].
Solution 64 User Guide Output 1 Name O001 Is Off and Ready Output 1 Name O001 Output is OFF, To Turn ON,Press ON. To Go Back Press OK Press OK or MENU To turn the output on, press [ON]. The keypad will display the following when the output is off and missing: The keypad will display the following when the output is on: Output 1 Name O001 Is Off and Ready Connection Trouble Press OK or MENU Output 1 O001 Output is ON, To Turn OFF,Press OFF.
Solution 64 User Guide Internal Audible Testing Press any key to abort Outputs > Output Testing > External Siren Test MENU 4-9-0 This menu allows you to test any external sirens which have been connected by your installer. The test will last for 5 seconds. Enter programming mode (PIN + MENU) then, 1. Press OK or MENU When the bell test is complete, the keypad will display the following: Enter [MENU] + [4] + [9] + [0]. If the system has been partitioned, the keypad will display a list of areas.
Solution 64 User Guide Communication / Reporting Programming options in this section relate to how you alarm syetm will communicate alarm information. Your installer will advise you on the exact makeup and configuration of your system. Comms > Commands > Call/Answer RAS MENU 5-0-1 This menu allows you to initiate a modem call to the installer’s off-site computer for programming changes or updates.
Solution 64 User Guide Domestic Phone Number 3 6789_ Press 6. Comms > Commands > Call Forward Off Number 0-9 OK to SAVE Using the numeric keys, enter all the digits of the third telephone number (if required). You can change a single digit by scrolling the cursor left [←] and right [→]. For special characters (eg. , = pause * or # etc), use the [↑] and [↓] keys. To clear all text from the cursor position to the right, press the [OFF] key. 7. Press [OK] to save and exit, or press [MENU] to cancel.
Solution 64 User Guide 3. Comms > Periodic Test > Send Test Report MENU 5-9-0 The display will show each parameter for the device one at a time on the third line of the screen. Keypad 001 Kp001 Graphic + Prox V1.01 Volts = 13.87 Press OK or MENU This menu allows you to test the reporting functions of the Solution 64 control panel by manually sending a ‘Test’ report to the receiving party (i.e. security company monitoring station, mobile telephone etc). 1. Enter [MENU] + [5] + [9] + [0]. 4.
Solution 64 User Guide Devices > Keypads > Backlight To determine the non system (zone) trouble condition, highlight the zone number Z001 to Z064) that you want to view using the [↑] and [↓] keys, then press [OK] to select. MENU 6-1-2 This menu allows you to adjust the brightness of the keypad’s LCD display backlight. Each keypad can have their display adjusted separately. Enter programming mode (PIN + MENU) then, 1.
Solution 64 User Guide Trouble Condition Mains Missing Battery Low Battery Missing Battery Reversed Description The system has detected that the AC mains supply has failed or is disconnected. If there is not a general power outage in your area then you should contact your security company. The backup battery has failed the periodic test which the system performs on a regular basis. You should contact your security company as the battery may need replacing.
Solution 64 User Guide System > Schedules > System > Commands > History Log MENU 7-0-2 This menu allows you to review the last 256 history events (from most recent to least recent). Each event will display: Line 1 Line 2 Line 3 Name This menu allows you to program 16 characters of text for each schedule name. Enter programming mode (PIN + MENU) then, 1. Sk001 Schedule 1 Name Sk002 Schedule 2 Name Sk003 Schedule 3 Name Press OK or MENU 2. - Displays the event description.
Solution 64 User Guide 3. Enter the new start and stop times in 24-hour format (00:00 to 23:59 hours). 4. Press [OK] to save and exit, or press [MENU] to exit without saving. Use the [] and [] keys to scroll through the different characters available. To clear all text from the cursor position to the right, press the [OFF] key. 4. Press [OK] to save and exit, or press [MENU] to exit without saving.
Solution 64 User Guide System > System Testing > Walk Test All Zones If the battery has passed the test, the keypad will display: MENU 7-9-0 This menu allows you to test all zones within an area at the same time. Enter programming mode (PIN + MENU) then, 1. Battery test Passed. Press OK to continue Press [MENU] + [7] + [9] + [0]. The keypad will display a list of areas that are available to walk test zones. 2.
Solution 64 User Guide I n s t al lat io n D etails INSTALLED BY: DATE PHONE: FAX: EMAIL: SERVICE PHONE: FAX: EMAIL: MONITORED BY: PHONE: FAX: EMAIL: WARRANTY EXPIRES: NOTES: Bosch Security Systems 09/06 BLCC110U 29
Solution 64 User Guide I I nd ex A Access Assignment ................................................................ 13 All On ................................................................................. 5, 8 Areas Area Status.......................................................................... 13 Diasrming an Area .......................................................... 8, 15 Move To Area ..................................................................... 14 Turn All Areas Off ............
Solution 64 User Guide Service Required.................................................................... 25 Silencing Alarms....................................................................... 8 Silent Alarms ............................................................................ 9 Smoke Detectors Sensor Reset ....................................................................... 17 Status Area ................................................................................... 13 Keypad .......
Bosch Security Systems 25 Huntingwood Drive Huntingwood, NSW 2128 Australia Phone: +612 9672 1777 Facsimile: +612 9672 1717 © 2006 Bosch Security Systems BLCC110U 920304 Issue FTR1.