BasicDome Series Instruction Manual EN Indoor Pendant & In-ceiling Models
Indoor Pendant & In-ceiling Model | Instruction Manual | Important Safeguards Important Safeguards 1. Read and Retain Instructions - All safety and operating instructions should be read before the unit is operated. Follow all operating and use instructions. 2. Heed Warnings - Adhere to all warnings on the unit and in the operating instructions. 3. Attachments - Attachments not recommended by the product manufacturer should not be used, as they may cause hazards. 4.
Indoor Pendant & In-ceiling Models | Instruction Manual | FCC Information FCC & ICES Information (U.S.A. and Canadian Models Only) This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Indoor Pendant & In-ceiling Models | Instruction Manual | Safety Precautions Safety Precautions CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. EN | 4 Sécurité ATTENTION : POUR ÉVITER TOUT RISQUE D’ÉLECTROCUTION, NE PAS OUVRIR LE BOÎTIER. IL N’Y A PAS DE PIÈCES REMPLAÇABLES À L’INTÉRIEUR. POUR TOUTE INTERVENTION, S’ADRESSER À UN RÉPARATEUR PROFESSIONNEL COMPÉTENT.
Indoor Pendant & In-ceiling Models | Instruction Manual | Safety Precautions Sicherheitshinweise VORSICHT: DAS GEHÄUSE ZUR VERMEIDUNG VON ELEKTRISCHEN SCHLÄGEN NICHT ÖFFNEN. DAS GERÄT ENTHÄLT KEINE VOM BENUTZER ZU WARTENDEN TEILE. REPARATUREN NUR VON FACHPERSONAL AUSFÜHREN LASSEN. Das Blitzsymbol im gleichseitigen Dreieck soll den Benutzer auf nicht isolierte “gefährliche Spannung” im Produkt hinweisen, die ausreichend stark sein kann, um die Gefahr von elektrischen Schlägen für Menschen darzustellen.
Indoor Pendant & In-ceiling Models | Instruction Manual | Safety Precautions Veiligheidsmaatregelen GEVAAR: OPEN DEZE BEHUIZING NIET, TENEINDE HET RISICO VAN ELEKTRISCHE SCHOKKEN TE VOORKOMEN. BINNENIN BEVINDEN ZICH GEEN DOOR DE GEBRUIKER TE REPAREREN ONDERDELEN. RAADPLEEG VOOR REPARATIE GEKWALIFICEERD SERVICEPERSONEEL. EN | 6 Precauzioni ATTENZIONE: PER RIDURRE IL PERICOLO DI SCOSSA ELETTRICA, NON APRIRE LE COPERTURE. L’INTERNO NON CONTIENE COMPONENTI CHE L’UTENTE PUÒ RIPARARE PERSONALMENTE.
Indoor Pendant & In-ceiling Models Instruction Manual | Safety Precautions Medidas de Segurança CUIDADO: PARA REDUZIR O RISCO DE CHOQUE ELÉCTRICO, NÃO ABRA AS TAMPAS. O INTERIOR NÃO CONTÉM PEÇAS QUE NECESSITEM DE MANUTENÇÃO. A MANUTENÇÃO DEVE SER EFECTUADA POR PESSOAL DE ASSISTÊNCIA TÉCNICA QUALIFICADO.
Indoor Pendant & In-ceiling Models | Instruction Manual | Contents EN | 8 Table of Contents BasicDome Instruction Book Important Safeguards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 FCC Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1 UNPACKING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Indoor Pendant & In-ceiling Models | Instruction Manual | Installation 1 CAUTION: Mounts must be properly and securely installed on a supporting structure capable of sustaining the unit weight.* Use care when selecting mounting hardware (not supplied) for installation. The mounting surface and the unit's weight should be carefully considered. UNPACKING Carefully remove the BasicDome camera module from the box. This camera module is the same one used in both the pendant and the in-ceiling models.
Indoor Pendant & In-ceiling Models | Instruction Manual | Installation 2.2 EN | 10 Wire the Connector (Pendant Housings) Wire the connector as shown below. CONTROL CONNECTOR 9 8 7 6 5 4 3 2 1 C- C+ GND RXD TXD GND Biphase Ground Biphase + RS-232 Ground RS-232 TX Biphase - RS-232 RX H 24 VAC Retaining Screw 24 VAC Line 24 VAC Neutral Not Used Figure 1: Control Connector Photo 4: Attach Pendant to Housing If a prewired mount was purchased, this step has been done for you at the factory.
Indoor Pendant & In-ceiling Models | Instruction Manual | Installation EN | 11 Red Dots Photo 6: Align Red Dots Photo 8: Turn Camera Module into Place 3. While holding the trim ring, gently insert the camera module into the housing until you feel some resistance. The unit should be only an inch or so from being completely inside the housing at this point. 5. With a small slotted screwdriver, tighten the locking screw located in the trim ring.
Indoor Pendant & In-ceiling Models | Instruction Manual | Installation 3 TRIM RING REPLACEMENT The Camera Module ships with an optional trim ring. If the trim ring currently installed on the camera module does not match the color of your pendant or ceiling décor, simply replace it with the one provided by following these steps. 3. Using a slotted screwdriver, carefully pry the trim ring tabs while pressing on the trim ring at the same time.
Indoor Pendant & In-ceiling Models | Instruction Manual | FastAddress 4 FASTADDRESS The following is an example of FastAddressing a BasicDome (ID number 26636, logical camera #3). EN | 13 4. Press ON-636-ENTER to display the screen shown in FIGURE 4. At this point, Camera ID 26636 will be the only camera in the FastAddress mode. 1. Call the camera up to the screen you are viewing (i.e. CAMERA-3-ENTER). 2. Press ON-999-ENTER to display the screen shown in FIGURE 2.
Indoor Pendant & In-ceiling Models | Instruction Manual | Troubleshooting 5 EN | 14 TROUBLESHOOTING GUIDE PROBLEM SOLUTION No Video. • Make sure the BasicDome is properly powered. • Ensure all cables are connected properly. • Make sure the address is set properly. • Make sure the biphase or RS-232 is connected. • Make sure other cameras can be controlled; if not, check the control system. Camera moves when moving other cameras. • Make sure the address is set properly.
Suspended Ceiling Mount Backbox Modules | Instruction Manual | Advanced Commands 6 EN | 15 BASICDOME ADVANCED COMMANDS CAMERA PTZ GENERAL SETUP To use Locked Commands, you must first unlock the BasicDome via OFF-90-ENTER. All locked settings, except FastAddress, can then be changed via ON-46-ENTER. Disallow these commands via ON-90-ENTER. Commands Keystrokes Description FastAddress ON-999-ENTER Sets/changes the dome address using the keyboard and on-screen menus.
Indoor Pendant & In-ceiling Models | Instruction Manual | Advanced Menu 7 EN | 16 ADVANCED MENU MAIN MENU This enhanced software makes programming and customizing your BasicDome easy. All settings can be edited using the Main Menu. To enter the Main Menu, press ON-46-ENTER. You then simply follow the on-screen commands to edit the settings. Remember, to access this feature, the system must be unlocked using OFF-90-ENTER.
Indoor Pendant & In-ceiling Models | Instruction Manual | Advanced Menu EN | 17 LENS SETUP Auto Focus – BasicDome automatically focuses on the subject in the center of the screen. The Factory Default* setting is SPOT. Choices: Constant . . . . . . . . . . .Auto Focus is always active, even while moving. Manual . . . . . . . . . . . .Auto Focus is inactive, manual focus must be used. *Spot . . . . . . . . . . . . . .
Indoor Pendant & In-ceiling Models | Instruction Manual | Advanced Menu EN | 18 DISPLAY SETUP Title OSD – Controls whether sector or shot title are displayed. The Factory Default* setting is ON. Choices: *On . . . . . . . . . . . . . . .Titles are displayed. Off . . . . . . . . . . . . . . .Titles are hidden. Camera OSD – Controls whether the camera information is displayed (such as digital zoom, Iris OPEN/close, etc.). The Factory Default* is ON. Choices: *On . . . . . . . . . . . . . .
BasicDome Series User Manual EN Indoor Pendant & In-ceiling Models NOTE: Remove this USER MANUAL and supply to user.
Indoor Pendant & In-ceiling Models | User Manual | Contents EN | UM2 Table of Contents BasicDome User Manual 1 1.1 1.2 1.3 1.4 1.5 2 ON-SCREEN PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .UM3 Saving a Scene (Preset) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .UM3 Preset Tour . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Indoor Pendant & In-ceiling Models | User Manual | On-Screen Programming 1 EN | UM3 ON-SCREEN PROGRAMMING The BasicDome software offers user-friendly on-screen programming. A few common commands are shown below. At the end of this section is a complete list of user commands for your reference. 1.1 Saving a scene (Preset) The BasicDome allows up to 99 scenes to be saved and recalled instantly. A saved scene is called a Preset.
Indoor Pendant & In-ceiling Models | User Manual | On-Screen Programming 1.3 EN | UM4 Setting the Preset Tour period To change the time duration between Presets during a Preset Tour, type ON-15-ENTER and use the joystick for adjustments (see FIGURE 4). Figure 5: Recording 1.5 Figure 4: Preset Tour Period Adjustments 1.4 Record/Playback Tours Two independent macros (series of commands) can be recorded: A & B.
Indoor Pendant & In-ceiling Models | User Manual | User Commands SETUP RECORD PRESET PTZ 2 EN | UM5 BASICDOME USER COMMANDS (Unlocked Commands) Commands Keystrokes Description Scan ON/OFF-1-ENTER Camera continuously pans in the last direction in which the joystick was moved. Moving the joystick stops the scan. AutoPan ON/OFF-2-ENTER Camera continuously pans back and forth between limits. Moving the joystick stops the scan.
Bosch Security Systems, Inc. 850 Greenfield Road Lancaster, PA 17601 EE.UU. Tel: 800-326-3270 Fax: 1-717-735-6560 www.boschsecuritysystems.com Robert Bosch GmbH Geschäftsbereich Postfach 10 60 50 70049 Stuttgart Telefax (0711) 8 11-12 34 Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven The Netherlands Tele +31 40 27 80000 © 2003 Bosch Security Systems GmbH 3935 890 35915 03-50 | Updated December 10, 2003 | Data subject to change without notice.