Precision Engineered Opto-Electronics™ INSTALLATION INSTRUCTIONS EX12LED Infrared LED Illuminator MAN-12LED-06
IMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep this instruction. 3. Heed all warnings. 4. Follow these instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Install in accordance with manufacturer instructions. 8. Do not install near any heat sources over manufacture specification temperature. 9. Only use attachments/accessories specified by the manufacturer. 10. Refer all servicing to qualified service personnel.
IMPORTANT For best results, please read this Instruction Booklet prior to installing the EX12LED Illuminator Unit. WARNING! CSA Certified / UL Listed CLASS 2 power adaptors must be used in order to comply with electrical safety standards. EU Directives covered by this declaration: 72/9/EC Low Voltage Directives 89/336/EEC Electromagnetic Compatibility Directive This installation should be made by a qualified service person and conform to all local codes.
NOTE: This equipment has been tested and found to comply with the limits for a digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. As part of its’ normal operation this device can generate radio frequency energy and if not installed and used in accordance with the installation manual may cause interference to radio communications.
INDEX – EX12LED Page Description.................................................. 1 Unpacking................................................... 2 Parts List..................................................... 2 Items Required for Installation .................... 2 Initial Preparations ...................................... 3 Guidelines................................................... 3 Section 1. Mechanical Specifications.......... 4 Section 2. Input Power Connections ........... 7 Section 3.
DESCRIPTION The EX12LED Infrared LED Illuminator provides night-time covert lighting for short range indoor and outdoor surveillance when used in conjunction with existing or newly installed monochrome cameras. Its compact cube shape is comprised of 42 LEDs mounted into a solid core CNC machined aluminum housing and beamed through a dark-tinted tough window. The EX12LED has an effective range up to 40 feet and is available in 850nm or 940nm with 30º or 60º beam spread.
UNPACKING Care should be taken when unpacking the shipped unit. Check the parts list and confirm all items have been located. Inspect the equipment thoroughly to ensure nothing was damaged in transit. Contact BOSCH Service Center if a problem is noted, see the rear page of this booklet for contact numbers.
INITIAL PREPARATIONS The EX12LED operates in either Vdc or Vac mode. The power input supply voltages can be 12-24VAC/DC See Section 2, Input Power Connections – Reference Only. Determine the optimum location for the Illuminator unit. See Section 3, Mounting-Illuminator Unit. All units have been tested prior to shipment, but it is advisable to check the unit’s operation before installation. GUIDELINES The installation and set-up of the EX12LED is explained in Sections 3 and 4.
1.
FIGURE 1 – 2 Front View 5
FIGURE 1 – 3 Rear View 6
2. INPUT POWER CONNECTIONS – Reference Only The voltage operating range is 12~24AC/DC. Note: input leads are not polarity dependent.
3. MOUNTING - ILLUMINATOR UNIT Select a suitable location that is protected from accidental damage, tampering, and environmental conditions exceeding the LED’s specifications. Caution: The selected mounting location should not place the camera in a situation where its environmental specifications could be exceeded. See page 17. Ensure the selected location is protected from falling objects, accidental contact with moving objects, and unintentional interference from personnel.
Secure all cabling. Installations on drywall must use a ¼” bolt and drywall butterfly type anchor or superior connection. The EX12LED can be mounted to any flat surface. The supplied “U” shaped mounting bracket allows for tilt as well as rotation. If this mounting bracket does not suit the needs of the installation, the installer can utilize either of the two ¼-20 camera-mount holes located in the housing (see Figure 1-3 on page 6). The choice of camera-type mounting brackets is left to the installer.
Note: The Tilt Adjustment screws should be loosened only. Do not remove these screws.
4. LED ADJUSTMENTS Note: The current setting of LED is 0.9A by manufacturer default. End user not advisable for adjustment. For photocell “On/Off” light-level adjustment, rotate VR2. Clockwise is off and counter-clockwise is on.
5. ILLUMINATOR UNIT RE-ASSEMBLY Make sure the input power wires are properly connected and tightened into the terminal block, all holes are sealed against moisture penetration and all mounting screws are tight. Step 5.1 - Check the gasket attached to the rear cover plate has not been dislodged or warped. Step 5.2 - Gently press the rear cover into place, making sure the gasket is properly seated and the photocell is centered in its viewing window. See Figure 5-1 on page 14. Step 5.
FIGURE 5 – 1 Rear Cover Re-Assembly 13
6. TROUBLESHOOTING GUIDE PROBLEM POSSIBLE SOLUTION Fuse Blows - Check fuse rating. - Check for shorting between the enclosure and the input power. Don’t know if LEDs are “ON” 850nm LEDs will have a faint red glow when “ON”.940nm LEDs are covert. Aim the LEDs directly at an IR sensitive camera to see the lights or wait for the LEDs to warm up (two minutes). Feel for warmth. LEDs are not “ON” Cover the photo sensor to activate power to the LEDs (up to 30 seconds delay for activation).
PROBLEM POSSIBLE SOLUTION LEDs are not turning “OFF” when sufficient ambient light is present - Make sure the photo sensor is not covered or hidden behind any object. - Check that the photocell is recessed in the viewing window. - Adjust the photocell’s variable resistor towards the “OFF” position. The LEDs will stay “ON” or “OFF” if the adjustments are at full turn.
7. GENERAL SPECIFICATIONS LED Type........... High Perf. 850nm / 940nm LED Beam Angles ... 60deg. (W), 30deg. (M) Operational Range................-20°C to +50°C ( -4°F to 122°F ) Humidity Range .............Up to 85% (relative) Power Supply ....................12V dc or 24V ac (60Hz), 9W Viewing Window ................................ Acrylic Housing ............................... CNC Aluminum Anodized Dimensions................... W: 2.875” (73.0mm) H: 2.750” (69.9mm) D: 2.750” (69.9mm) Weight ..........
Americas Bosch Security Systems, Inc. 850 Greenfield Road Lancaster, Pennsylvania 17601 USA Telephone+ 1 888-289-0096 Fax + 1 585-223-9180 Email: security.sales@us.bosch.com www.boschsecurity .us Europe, Middle East, Africa: Bosch Security Systems B.V. P.O. Box 80002 5600 JB Eindhoven, Netherlands Phone: + 31 40 2577 284 Fax: + 31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Asia Pacific: Bosch Security Systems Pte Ltd.