D8125MUX | Operation and Installation Guide | 3.0 Installation
20 Bosch Security Systems, Inc. | 10/09 | F01U034973-02
3.12 DS7432 Eight Input Remote Module
This device type reserves eight points on the
multiplex bus. Each D8125MUX supports fifteen
DS7432s on the D9412GV2, D9412G, D9412, and
D9112 Control Panels, up to eight on the D7412GV2,
D7412G, D7412, and D7212 Control Panels, and up
to four on the D7212GV2 and D7212G Control
Panels. The DS7432s occupy groups of eight points;
however, when programming the DS7432 with the
multiplex point programmer, program them as four
sets of dual points. For example, if using a DS7432
on the system for Points 9 through 16, program
Points 9, 11, 13, and 15 as dual points with the even
points being added automatically. Program starting
point locations for the DS7432 on the D9412GV2,
D9412G, D9412, and D9112 Control Panels as
follows: 9, 17, 25, 33, 41, 49, 57, 65, 73, 81, 89, 97,
105, 113, 121. Refer to
Table 14.
Table 14: DIP Switch Settings
DIP Switch
Zonex 1/
Zonex 2
1 2 3 4 5
9/129 Open Open Open Open Closed
17/137 Open Open Open Closed Open
25/145 Open Open Open Closed Closed
33/153 Open Open Closed Open Open
41/161 Open Open Closed Open Closed
49/169 Open Open Closed Closed Open
57/177 Open Open Closed Closed Closed
65/185 Open Closed Open Open Open
73/193 Open Closed Open Open Closed
81/201 Open Closed Open Closed Open
89/209 Open Closed Open Closed Closed
97/217 Open Closed Closed Open Open
105/225 Open Closed Closed Open Closed
113/233 Open Closed Closed Closed Open
121/241 Open Closed Closed Closed Closed
Points 127/128 and 247/248 cannot be
programmed when using DS7432s
(D9412GV2, D9412G, D9412, or D9112).
Program starting point locations for the DS7432 on
the D7412GV2, D7412G, D7412, D7212 as follows:
9, 17, 25, 33, 41, 49, 57, and 65. Program starting
point locations for the DS7432 on the D7212GV2 and
D7212G as follows: 9, 17, 25, and 33. Failure to
observe this programming requirement will result in
intermittent missing conditions. All eight points on the
DS7432 must also have a Point Index assigned to
them. If any of the eight point inputs are not required
on the device, place the 47 kΩ EOL resistor on the
point input terminals. Refer to
Table 15 for
information on configuring the point type. Tamper
conditions on multiplex points are treated as Missing
conditions by the control panel. Removing the cover
and activating the tamper results in a missing
condition for all eight points.
Table 15: DS7432 Point Type Configuration
Device Type Point Type Point Response
DS7432 Eight Input 6 Configurable
Remote Module (NO or NC)
3.13 DS7465(i) Input/Output Module
This device type reserves a single point on the MUX
bus and provides a Form C (NO, C, NC) relay output.
The relay output number assigned to this module is
the same as the point number assigned to it. For
example, if this device was programmed as Point 27,
the relay number is also 27.
The relay output on this module is a fully
programmable relay and follows the relay
programming of the control panel.
The maximum number of DS7465i Modules that can
be placed on the control panels is 56 as points 9
through 64 for the D9412GV2, D7412GV2, D9412G,
D7412G, D9412, D7412, D7212, and D9112; and 16
as points 9 through 24 for the D7212GV2 and
D7212G. Place the DS7465(i) on the D8125MUX
connected to Zonex 1.
If only the relay is required for the installation, assign
a Point Index for the programmed point location, and
place a 47 kΩ EOL resistor on the point input
terminals. Refer to
Table 16 for point type
configuration.
Table 16: DS7465(i) Point Type Configuration
Device Type Point Type Point Response
DS7465(i) Input/Output 3 Configurable
Module (NO or NC)
Tamper conditions on multiplex points are treated as
Missing conditions by the control panel. Using
DS7465i Input and Output Modules on the system
does not interfere with the use of D8129 OctoRelay
Modules.