Installation Instructions

Table Of Contents
Electrical connection en-us
9
max. 2¾" (69mm) + fitting/conduit 1" (25mm)
min. 1" (25mm) air clearance
approx. 12" (300mm)
junction box
flexible conduit approx. 3ft. (900mm)
Power supply
All models must be connected with the included 39" (1m) flexible conduit.
Models 240V AC, 3-wire, 60Hz system: cir-
cuit breaker
208V AC, 3-wire, 60Hz system: cir-
cuit breaker
NIT5060UC 30A 30A
NIT8060SUC 30A 30A
NIT8060UC 30A 30A
NITP060SUC 30A 30A
NITP060UC 30A 30A
NIT5660UC 40A 40A
NIT8660SUC 40A 40A
NIT8660UC 40A 40A
NITP660SUC 50A 50A
NITP660UC 50A 50A
NIT5460UC 30A 30A
5.2 Connecting electrical supply
WARNING
Before installing, turn power OFF at the service panel.
Lock service panel to prevent power from being turned
ON accidentally.
Note:If the cooktop is installed and connected as speci-
fied here, it will be grounded in compliance with the Na-
tional Electrical Code.
1. Install a suitable junction box (not furnished).
The branch-circuit breakers ampacity, the wire sizes
and the connections must conform to the requirements
of the National Electrical Code or Canadian Electrical
Code and all local codes and ordinances.
2. Attach the flexible conduit to the junction box.