Smoke Alarm FERION 1000 O en
Smoke Alarm Table of Contents | en 3 Table of contents 1 Graphics 4 2 Introduction 6 3 Mounting 7 4 Maintenance 5 Technical data 10 6 Customer Service 11 Bosch Sicherheitssysteme GmbH 9 08.15 | 3.1 | F.01U.309.
en | Graphics Smoke Alarm 1 Graphics minimum (1) additional unsuitable (2.A) 5- 0. (2.B) (2.C) (2.D) ≤1m >1m 1m m -1 0-20° 5 0. 0.5m >20° 08.15 | 3.1 | F.01U.309.
Smoke Alarm Graphics | en 1 x 3 mm (5) (3) 5 1 A A 1 B 2 x 3 mm 1 (4) 60 mm B 1 1 2 (6) + 1 + (7) <2s Bosch Sicherheitssysteme GmbH 08.15 | 3.1 | F.01U.309.
en | Graphics Smoke Alarm 2 Introduction The FERION 1000 O smoke alarm device with built‑in siren (4.1), big button for operation (4.2) and replaceable batteries (6.1) is solely designed for residential applications. The device reliably warns you of the emergence of a fire in your house or flat. If the smoke emissions exceed a certain limit, an alarm is raised. More information, CE declaration, and declaration of performance is available on www.boschsecurity.com/ferion/.
Smoke Alarm Graphics | en 7 Used batteries or old devices are not to be disposed of with the household waste. Dispose of them according to the guidelines for electric and electronic waste at the local collection points. Parts included 1 smoke alarm device: base (3.A) and detector head (3.B), 2 batteries, fastening material: 1 screw, 1 plug 3 Mounting Notice! The device is designed for mounting according to DIN 14676 on flat or slanted ceiling. Wall mounting is not allowed. Perform the following steps.
en | Graphics Smoke Alarm 3. For each device: Mounting the base. (5) Observe the marks (5.1) for alignment with BOSCH label/siren. 4. Functional check, page 9, for each device after setting it up into operation.
Smoke Alarm Graphics | en 9 Mounting the base Mount the base with one central screw and plug. (5.A), or optionally use two screws and plugs. (5.B) To set the device into operation you screw the detector head to its base by twisting it clockwise until it latches. (6) 4 Maintenance Functional check A visual inspection and a functional check must be performed for each device monthly. After the functional check the device is muted for 10 min, even when an alarm will be triggered.
en | Graphics Smoke Alarm 2. Screw the head to its base again and perform the functional check. Polluted smoke chamber If the siren sounds short 3 times every 43 s (polluted smoke chamber), then you have to replace the device. 5 Technical data Sound pressure level at a distance of ≥85 3m in dB(A) Power supply (2 x 1.5V, replaceable GASSNER LR6 batteries) FUJITSU LR6 G Dimensions (diameter x height, mm) 119 x 50 Weight, incl.
Smoke Alarm Graphics | en 11 *** based on typical storage temperature (-5 … +30 °C) and typical operating temperature (+5 … +30 °C) and monthly functional tests Certification CE , Harmonized standards EN 14604:2009-02 Signals Mode Audible Normal - Functional test OK 3 x ≥85 db(A) / 4 s Alarm 3 x ≥85 db(A) / 4 s Weak battery 1 x short / 43 s Polluted smoke chamber 3 x short / 43 s 6 Customer Service Replacement of the product is only possible with proof of purchase during guarantee.
en | Graphics Smoke Alarm Great Britain Ireland Robert Bosch Ltd. (B.S.C.) Origo Ltd. P.O. Box 98 Unit 23 Magna Drive Broadwater Park Magna Business Park North Orbital Road City West Denham Dublin 24 Uxbridge Tel. Service: UB 9 5HJ (01) 4666700 Tel. Service: Fax: (01) 4666888 (0344) 7360109 E-Mail: boschservicecentre@bosch.co m 08.15 | 3.1 | F.01U.309.
Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany www.boschsecurity.