UHI/UHO Series UHI-OG-0 | UHI-OGS-0 | UHO-HGS-10 | UHO-HBGS-10 | UHOHBPS-10 | UHO-HGS-50 | UHO-HBGS-50 | UHO-HPS-50 | UHOHBPS-50 | UHO-HBGS-60 en User Manual
UHI/UHO Series | en 3 1 Unpacking 11 2 Service 11 3 Description 12 4 Installation 13 4.1 Tools required 13 4.2 Camera requirements 13 4.3 Cable requirements 14 4.3.1 Video transmission (coaxial) 14 4.3.2 Input power cord 14 4.3.3 Lens control cable 15 4.4 Housing mounting 15 4.5 Opening the cover 16 4.6 Camera/Lens installation 16 4.7 Camera/Lens wiring 18 4.7.1 Fittings 18 4.7.2 Conduit 19 4.7.3 Feed-through Wiring 19 4.7.4 Power Connections 20 4.
en | UHI/UHO Series 6 Operation 28 7 Maintenance 28 8 Exploded view 29 docnumber | V 2.0 | 2007.
UHI/UHO Series | en 5 Important safety instructions Read, follow, and retain for future reference all of the following safety instructions. Heed all warnings on the unit and in the operating instructions before operating the unit. 1. Cleaning - Unplug the unit from the outlet before cleaning. Follow any instructions provided with the unit. Generally, using a dry cloth for cleaning is sufficient, but you can also use a moist fluff-free cloth or leather shammy.
en | UHI/UHO Series – For external power supplied units, use only the recommended or approved power supplies. – For limited power source units, this power source must comply with EN60950. Substitutions may damage the unit or cause fire or shock. – For 24 VAC units, voltage applied to the unit's power input should not exceed 25.4 VAC. User-supplied wiring must comply with local electrical codes (Class 2 power levels).
UHI/UHO Series | en 7 DANGER! High risk: This symbol indicates an imminently hazardous situation such as "Dangerous Voltage" inside the product. If not avoided, this will result in an electrical shock, serious bodily injury, or death. ! ! WARNING! Medium risk: Indicates a potentially hazardous situation. If not avoided, this could result in serious bodily injury or death. WARNING! Medium risk: Indicates a potentially hazardous situation. If not avoided, this may result in minor or moderate injury.
en | UHI/UHO Series Camera signal - Protect the cable with a primary protector if the camera signal is beyond 140 feet, in accordance with NEC 800 (CEC Section 60). Coax grounding – Ground the cable system if connecting an outside cable system to the unit. – Connect outdoor equipment to the unit's inputs only after this unit has had its grounding plug connected to a grounded outlet or its ground terminal is properly connected to a ground source.
UHI/UHO Series | en 9 Power lines - Do not locate the camera near overhead power lines, power circuits, or electrical lights, nor where it may contact such power lines, circuits, or lights. Video loss - Video loss is inherent to digital video recording; therefore, Bosch Security Systems cannot be held liable for any damage that results from missing video information.
en | docnumber | V 2.0 | 2007.
UHI/UHO Series Unpacking | en 1 11 Unpacking This electronic equipment should be unpacked and handled carefully. Verify that the items listed in Table 1.1 are included for the model ordered. Qty. Item Part 1 Housing (with correct model number) ABS 1 Spacer, 4 mm ABS 1 Spacer, 9 mm ABS 2 Screw, 1/4-20 x 1/4 in SS 2 Screw, 1/4-20 x 3/8 in SS 2 Screw, 1/4-20 x 3/4 in SS 2 Screw, 1/4-20 x 5/8 in SS 2 Screw, 1/4-20 x 7/16 in SS 2 Screw, 1/4-20 x 1/2 in SS 3 Screw, tamper-resistant M3.
en | Description 3 UHI/UHO Series Description The UHI/UHO series are attractively styled housings for indoor and outdoor use. These housings meet customer demand for appearance, cost competitiveness, and easy installation. See Table 3.1 for a description of indoor models. Heaters and blowers for all models operate at 50/60Hz. The 4pin models have a 4-pin connector and a BNC connector instead of feed-through fittings.
UHI/UHO Series Installation | en 4 4.1 4.2 13 Installation ! CAUTION! Installation should only be performed by qualified service personnel in accordance with the National Electrical Code or applicable local codes. ! CAUTION! These units must be properly and securely mounted to a supporting structure capable of sustaining the unit weight. Use care when selecting mounts or pan/tilts (not supplied) for installation; the mounting surface and unit's weight should be carefully considered.
en | Installation UHI/UHO Series 4.3 Cable requirements 4.3.1 Video transmission (coaxial) Cable type runs < 300m (1000 ft) runs < 600m (2000 ft) Cable diameter (outer) Cable shape Cable shield Center conductor DC resistance RG-59/U RG-11/U Cable impedance Certificating authority Environmental Temperature rating Reference type RG-59/U RG-11/U 4.6 mm to 7.9 mm (0.18 in to 0.
UHI/UHO Series Installation | en 15 Cable type H05RN-F 3 G 0.75; H05RN-F 3 G 1.00 4.6 to 7.9 mm (0.18 to 0.31 in) Round 3 or 2 300 V VDE Outdoor rated Olflex rubber cable 1600 252; Olflex rubber cable 1600 253 Cable diameter (outer) Cable shape Conductors Voltage rating Certificating authority Environmental Reference type Table 4.4 Power cord specifications for Europe 4.3.3 Lens control cable Cable type Cable diameter (outer) Jacketed multiconductor cable 4.6 to 7.9 mm (0.18 to 0.
en | Installation UHI/UHO Series For mounting with rear connections For mounting with feed-through wiring Fig. 4.1 Thread holes for mounting with rear connections, or for feed through wiring 4.5 Opening the cover ! WARNING! The heater will be HOT when in operation - DO NOT TOUCH. Always switch heater OFF when working on the camera. Open the cover by unlatching the three latches on the side of the housing. See Figure 4.2.
UHI/UHO Series Installation | en 3. 17 For installation of zoom lens cameras: a. Attach the lens to the camera. b. Use the various 1/4-20 screws and appropriate 4 mm and/or 9 mm spacers provided to mount the camera and the lens to the camera tray. This camera tray is already pre-installed. Fig. 4.3 Spacers for mounting zoom lens and camera 4. Mounting fixed lens cameras in all housings: c. Attach the lens to the camera. d.
en | Installation UHI/UHO Series Fig. 4.4 Optional camera tray type A for fixed lens camera Fig. 4.5 Sliding camera/lens tray assembly into slot 4.7 Camera/Lens wiring See Section 3.2 Outdoor 24 volt units and Section 3.4 Outdoor 230 volt units for UHO-HBPS-10, UHO-HPS-50 and UHO-HBPS50 models. ! 4.7.1 CAUTION! Use only cables meeting specifications in Section 4.3 Cable requirements,to wire cameras and lenses. Fittings The 3/8-inch NPT fitting accepts a round cable with diameter from 4.0 mm (0.
UHI/UHO Series Installation | en ! 4.7.2 19 CAUTION! Always securely tighten all fittings to ensure a liquidtight seal. Failure to do so could allow water to enter the housing and damage the camera and lens. If a sealant is used, be sure it is a neutral cure type. Sealants that release acetic acid may harm camera electronics. Use of drip loops is recommended on the wiring outside of the rear end cap. Conduit These housings allow direct connection of conduit. 4.7.3 1.
en | Installation UHI/UHO Series wire. Failure to do this will result in water damage to all electronic parts. 4.7.4 4. Attach the foot to the top bracket of the mount. 5. Be sure that the holes in the rear cap are covered with the rubber plugs provided. Push in until flush and then release. Power Connections Power into the housings is to be supplied using type UL Standard SJ cord (or better) acceptable for outdoor use.
UHI/UHO Series Installation | en ! 21 CAUTION! For compliance with safety regulations, the external ground wire must always be connected to the main ground post. a. To attach the external safety ground wire, remove the nut, washers and the external ground wire lug from the ground post. b. Strip and crimp the external ground wire into the lug. c. Reattach the ground connections in the order shown in Figure 4.7. Nut Lock washer Flat washer External ground lug External ground post Fig. 4.
en | Installation ! UHI/UHO Series CAUTION! Be sure to securely tighten all fittings to ensure a liquid-tight seal. Failure to do this could allow water to enter the housing and damage electronic parts, camera, and lens. 5. Connect the supply power wires to the terminal block. See Figure 4.8. Strip no less than 6 mm (0.25 in) and no more than 8mm (0.31 in) of insulation away from the wire. Be sure not to nick the wires. 6.
UHI/UHO Series Installation | en 23 To camera To accessories BNC cable to camera Power input grounding post L FUSE N G N G x N L L Lens wiring 1 2 Ground test connector Do NOT disconnect Ground stud housing bottom Ground cable to housing top L N G Power input connector Video input connector Lens Fig. 4.8 Terminal wiring diagram Pin N L G Color Blue Brown Green Connection Power connection Power connection G (safety ground) Table 4.
en | Installation ! 4.8 UHI/UHO Series CAUTION! For security protection of the device, the branch circuit protection must be secured with a maximum fuse rating of 16A. This must be in accordance with NEC 800 (CEC Section 60). 7. On heater and heater/blower units, make sure the heater and fan wires stay connected to the terminal block. 8. Make sure the BNC cable is separated from the Mains power and heater. Video coax connection See Table 3.2 and Table 3.
UHI/UHO Series Installation | en 4.9 25 Lens wiring 1. ! CAUTION! Use only cables meeting specifications in Section 4.3 Cable requirements, for wiring cameras and lenses. 2. ! Install the 3/8-inch NPT fitting into the middle hole in the rear cap. If installing a zoom lens, insert the lens control cable through the last fitting at the rear of the housing. Attach the lens wiring to the lens mating connector and connect it to the lens.
en | Installation 4.12 4.13 UHI/UHO Series 4. Install screws into the appropriate holes. 5. Close the cover and secure the latches. 6. Optional tamper-resistant screws are provided with the housing. If desired, secure the latch using these three screws and the provided tamper-resistant wrench. Sunshield 1. Loosen the two screws (M4 x 10) on the top of the housing. 2. Slide the sunshield to the desired position. It has a range of 50 mm (2 in). 3.
UHI/UHO Series UHO-HBPS-10, -50, and UHO-HPS-50 | en 27 5 UHO-HBPS-10, -50, and UHO-HPS-50 5.1 Camera/lens wiring Installation for these models is in accordance with Section 4 Installation, except as noted below. ! CAUTION! Use only 24 VAC power for UHO-HBPS-10 models. These models have female connectors to prevent them from being connected to the mating connector that is provided with UHO-HPS-50 and UHO-HBPS-50 models that require 230 VAC.
en | Operation UHI/UHO Series 3. The terminal block provided on these units accepts wire ranging from 0.5 mm2 to 2.5 mm2 (20 AWG to 14 AWG). When using larger wire sizes, splice to a smaller size wire at the terminal block end. 4. Connect the power input cable to the screw terminals on the provided mating connector. See Figure 5.1 and Table 5.1. Pin 1 2 3 4 Function AC neutral AC live No Connection Ground Harness wire color Blue Brown Do not use Green/yellow Table 5.
UHI/UHO Series Exploded view | en 8 29 Exploded view Fig. 8.1 Exploded view Bosch Security Systems User Manual F.01U.026937 | V 2.0 | 2007.
en | Exploded view UHI/UHO Series 1. Sunshield (ZYB01) 7. Non-feed through base plate (DZ4P1) 2. Top cover (XG001) 8. Window + window defrosters: 24 VAC (BTQ24) 120 VAC (BJQ15) 23 VAC (BJQ23) 3. Bottom cover plus latches, glance 9. version (XDF01) 4. Bottom cover plus latches, 4 pin version (XD4P1) 10. Bracket for UHI series (FZ001) Bracket + PCB/24 VAC heater, no blower (FZP24) Bracket + PCB/24 VAC heater, incl.
Bosch Security Systems Robert-Koch-Straße 100 D-85521 Ottobrunn Germany Telefon 089 6290-0 Fax 089 6290-1020 www.boschsecuritysystems.