Bosch CRC200 Room Controller Installation Manual

6 720 821 651 (2017/05)CRC200
Commissioning | 13
Following automatic configuration, the display switches to guided system configuration. Which settings are available during
guided system configuration depends on the installed system.
While in guided system configuration you can press the Back button to switch to the previous menu item.
A flashing display means you should turn the dial to change the setting or press the dial to confirm the shown setting.
Available only on the user interface for heating zone 1 (not visible when a combi boiler is used).
DHW appears on the display. You can set wether a hot water system is installed or how it is
installed. For further details see table 5.
If the display is not flashing, press the dial.
Turn the dial to change the setting.
Press the dial to switch to the next setting.
Available only on the user interface for heating zone 1.
LLH Sensor appears on the display. You can set wether a low loss header is installed and where
its temperature sensor is connected. For further details see table 5.
Press the dial to make the flashing default setting appear.
Turn the dial to change the setting.
Press the dial to switch to the next setting.
Available only on the user interface for heating zone 1.
Recirculation appears on the display. You can set wether a recirculation pump is installed. For
further details see table 5.
Press the dial.
Turn the dial to change the setting.
Press the dial to switch to the next setting.
Heat. System appears on the display. You can set wether high temperature or low temperature
heat radiation applies. For further details see table 5.
Press the dial to make the flashing default setting appear.
Turn the dial to change the setting.
Press the dial to switch to the next setting.
Max. Suppl.T. appears on sthe display. You can set the maximum supply temperature. For
further details see table 9.
Press the dial.
Turn the dial to change the temperature.
Press the dial to switch to the next setting.
Frost protect appears on the display. You can set wether frost protection depends on room
temperature or outdoor temperature. Outdoor temperature sensor must be installed for
outdoor dependent frost protection. For further details see table 9.
Press the dial to make the flashing default setting appear.
Turn the dial to change the setting.
Press the dial to switch to the next setting.
Basic settings
Table 4 Basic settings
6 720 811 156-30.1O
DHW
DHW
6 720 811 156-31.1O
No
No
6 720 811 156-32.1O
Recirculation
Recirculation
6 720 811 156-33.1O
High Temp
High Temp
6 720 811 156-34.1O
Max. Suppl. T.
Max. Suppl. T.
6 720 811 156-35.2O
by Room Temp.
by Room Temp.