Bosch Installation Manual

Inspection and maintenance
69
Greenstar – 6721822579 (2021/01)
Rinse the heat exchanger with water from the top.
Fig. 96 Rinsing the heat exchanger
Clean the condensate tray (with reversed brush).
Fig. 97 Cleaning the condensate tray
Rinse the heat exchanger with water from the top.
Clean the condensate trap connection.
Close the inspection opening again using a new gasket and tighten
the screws with a torque between 4.1 ft-lbs (5.5 Nm) and 5.1 ft-lbs
(7.0 Nm).
15.1.7 Cleaning condensate trap
Remove condensate trap (steps 1 and 2) and check heat exchanger
orifice for clear passage.
Fig. 98 Removing the condensate trap
Remove and clean the condensate trap lid.
Check condensate hose and clean if necessary.
Fill the condensate trap with approx. 1 cup (1/4 l) of water and
reinstall it.
15.1.8 Checking the mixer diaphragm
Open the mixer unit.
Carefully remove the diaphragm from the fan air intake and check for
contamination and cracks.
Fig. 99 Opening the mixer unit
Insert the diaphragm into the fan connector.
The diaphragm flaps must open upwards.
▶Close the mixer unit.
6 720 612 664-18.1R
2
6 720 610 332-75.2R
6 720 641 933-93.1o
1
2
1
2
3
6 720 641 933-94.1o