66 | Inspection and maintenance
Greenstar6 720 806 992 (2013/07)
With the cleaning blade, clean the heat exchanger block from the
bottom to the top.
Fig. 89 Cleaning the heat exchanger with the cleaning blade
Clean the heat exchanger block with the brush from top to bottom.
Fig. 90 Cleaning the heat exchanger with the cleaning brush
Remove burner ( Chapter 14.1.5 “Burner servicing”).
Rinse the heat exchanger with water from the top.
Fig. 91 Rinsing the heat exchanger
Clean the condensate tray (with reversed brush).
Fig. 92 Cleaning the condensate tray
Rinse the heat exchanger with water from the top.
Clean the condensate trap connection.
Close the inspection opening again using a new gasket and tighten the
screws with approx. 3.69 ft.-lbf. (5 Nm).