installation manual

Table Of Contents
Installation | 37
6 720 806 992 (2013/07)Greenstar
Fig. 27 Vent and combustion air pipe position
Direct vent (sealed combustion):
[1] Forced Air Inlet
[2] Gravity Air Inlet
[3] Exhaust terminal
X
1
1 foot (305 mm)
X
2
3 feet (915 mm)
X
3
1 foot (305 mm)
X
4
5 feet (1 525 mm)
X
5
7 feet (2 135 mm) above public walkway
Y
A
At least 1 feet (305 mm) above grade and snow line
Y
B
Exhaust terminal must be at least 3 feet (915 mm) above forced
air inlet within 10 feet (3 050 mm)
Fan assisted appliance (non-sealed combustion):
[1] Forced Air Inlet
[2] Gravity Air Inlet
[3] Exhaust terminal
X
1
1 foot (305 mm)
X
2
3 feet (915 mm)
X
3
4 feet (1 220 mm)
X
4
5 feet (1 525 mm)
X
5
7 feet (2 135 mm) above public walkway
Y
A
At least 1 foot (305 mm) above grade and snow line
Y
B
Exhaust terminal must be at least 3 feet (915 mm) above forced
air inlet within 10 feet (3 050 mm)