Bosch Installation Manual

Inspection and maintenance
67
Greenstar – 6721822579 (2021/01)
Fig. 88 Removing the plate heat exchanger
Install new plate type heat exchanger with new gaskets and reconnect
the hydraulic assembly in reverse order.
Check all connections used during maintenance for leaks.
15.1.4 Checking electrodes
Remove electrode set including gasket and check electrodes for
contamination; clean or replace, if required.
Reinstall electrode set with new gaskets and check for leaks.
Fig. 89 Reinstalling the electrode set
Fig. 90 Check for leaks
15.1.5 Burner servicing
DANGER
Fire danger!
The burner may be operated only while installed in a wall-mounted
gas condensing boiler.
Remove burner lid (steps 1 - 4).
Fig. 91 Removing the burner cover
Remove burner and clean its components.
Fig. 92 Burner
Reinstall burner in reverse order, including a new gasket if necessary.
Adjust the gas-air ratio (page 62)
0010032724-001
0010 006 917-001
2-1/4 + 3/4 ft.-lbf.
3 + 1 Nm
0010 006 918-001
Gas/Gaz?
1
2
4
6 720 641 933-95.1o
3
7 181 465 330-08.2R