Datasheet

BMI160
Data sheet
BST-BMI160-DS000-07 | Revision 0.8 | February 2015 Bosch Sensortec
© Bosch Sensortec GmbH reserves all rights even in the event of industrial property rights. We reserve all rights of disposal such as copying and passing on to
third parties. BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany.
Note: Specifications within this document are preliminary and subject to change without notice.
softreset: 0xB6
triggers a reset including a reboot. Other values are ignored. Following a delay, all user
configuration settings are overwritten with their default state or the setting stored in the
NVM, wherever applicable. This register is functional in all operation modes.
step_cnt_clr: 0xB2
triggers a reset of the step counter. This register is functional in all operation modes.