Fig. 32 Plumbing Connections (with shutoff valves)
and Pressure Relief Valve
1 Water filter
3.11 Domestic hot water recirculation
The following drawing is provided to outline one
possible recirculation design using the water heater in
conjunction with an Ariston mini tank water heater.
Recirculation directly through the tankless water heater
is also allowed. This schematic is for illustration only and
must not be used for actual installation without
appropriate engineering and technical advice from a
properly licensed professional in the locality where the
installation is made.
Fig. 33 Recirculation application
1 Full port isolation valve
2 Circulator (pump)
3 Check valve
4 PRV
5 Expansion tank
The use of a small electric mini-tank water heater (4-6
gallon size) should be used for this application and
designed so the pump will circulate the water through
the mini-tank and the building's hot water return loop
only. Timed or thermostatically controlled operation of
the pump is commonly done. Contact Bosch Water
Heating if further information is needed.
3.12 Measuring gas pressure
Confirm gas pressure upon installation.
Connecting manometer
B Shut off gas supply at installer supplied shutoff valve
for this water heater.
B Remove front cover and locate inlet gas pressure
measuring point (see Fig. 35).
B Loosen screw inside left test point fitting (do not
remove) and connect manometer tube to test point.
Remove screw completely if correct size tapping is
available.
Static Pressure Test
B Turn gas supply back on.
B Record static gas pressure reading in table 14.
Operating Pressure Test
B Press ON/OFF button to turn off the appliance.
B Press and hold "Program" (P) button and press ON/
OFF button to turn appliance ON.
Fig. 34
B As soon as '188' is displayed, release "Program"
, button and the display should read P2.
B Press or until P1 appears.
Note: While in this mode the appliance will run
constantly at maximum power and allow
maximum water flow.
For inlet gas pressure adjustment consider the
following table:
B Turn on high volume of hot water flow (at least 6
gpm) and heater will ignite. If heater display reverts to
P2, open more hot water fixtures to allow sufficient
flow. Press until P1 reappears on display.
6720608158-77.1AL
1
4
5
3
2
Ariston Minitank
GWH
2700
ES
Gas type NG LPG
3.5” WC 8” WC
Table 13 Minimum inlet gas pressure under full operation