Reference View
1. Auto-sensing Mic Headset Connector -
Accepts headsets with monaural headphones; either dynamic and electret microphone.
2. Panel Mic Connector -
Accepts an electret gooseneck microphone. The model MCP-90 series panel mic connector is a 1/4” stereo plug, with
a threaded shaft for easy installation.
3. Vol u m e C o n t r ol -
Adjusts headphone volume only.
4. Vox Trimmers -
Used with the voice-activated microphone feature. Separate trimmers to adjust the voice activation level for the
headset and panel microphones.
5. Headset and Panel Mic Keys -
Used to manually activate either the headset or panel microphone, whichever is being used.
6. Mic Gain -
Used to adjust the level of audio sent from the microphone.
7. All Talk Key -
Used to talk to any station on any channel. This includes all the MS-4002 channels and any channels connected
through an EMS-4001 Expansion Station.
8. PA Key -
If the MS-4002 is connected to a PA system, this key may be used to talk over the public address system.
9. Mic Kill Key -
Used to turn off the microphones of any intercom station on a channel. Also, used to activate program inputs and the
audible beep feature for incoming calls.
10. Intercom Talk Keys -
Momentary or latching (hands-free) operation possible.
11. Call Keys -
Used to place calls on intercom channels and to indicate incoming calls.
12. Intercom Listen Keys -
Momentary or latching (hands-free) operation possible.
FIGURE 1. MS-4002 Reference View
1 23678 10 11 13 14
459 12
21
18
19
20
16
17
15