Install Instructions
Table Of Contents
- Table of contents
- 1 Key to symbols and safety instructions
- 1.1 Key to symbols
- 1.2 Safety precautions
- 2 Information about the heater
- 3 Regulations
- 4 Installation
- 5 Operation instructions
- 6 Maintenance
- 7 Service
- 8 Troubleshooting
- 9 Spare Parts
- 10 Environment / disposal
- Indice
- 1 Explicación de la simbología y instrucciones de seguridad
- 1.1 Explicación de los símbolos
- 1.2 Instrucciones Importantes de Seguridad
- 2 Información sobre el calentador
- 3 Reglamentos
- 4 Instalación
- 5 Instrucciones de funcionamiento
- 6 Mantenimiento
- 7 Problemas
- 8 Piezas de repuesto
- 9 Protección del medio ambiente/reciclaje
- Sommaire
- 1 Explication des symboles et mesures de sécurité
- 1.1 Explication des symboles
- 1.2 Importantes instructions de sécurité
- 2 Informations relatives au chauffe- eau
- 3 Règlementations
- 4 Installation
- 5 Instructions d'utilisation
- 6 Maintenance
- 7 Diagnostic de pannes
- 8 Liste des pièces de rechange
- 9 Protection de l’environnement/ Recyclage
6 720 647 022 (2014/06)Tronic 5000C
Installation | 11
US wiring
• The minimum recommended wire size is 6 AWG. (The
terminal block will accept cables up to 6 AWG size).
• The cable entry is via the 1¼ inch cable entry hole on the
bottom right hand edge of the back plate.
• Strip and connect the conductors from each circuit breaker
to an L1/L2 pair on the terminal block. Conductors from
each phase must be connected consistently to either L1 or
L2 as shown in the Fig. 6.
• Any insulation on the ground wires should be stripped back
about ¾ inch. The ground leads must be connected.
• Make sure the terminal block screws are tightened
securely. Loose connections can cause wires to overheat.
• Make sure that the ground wires are wrapped around the
terminal stud and into the saddle washer. The nut should be
tightened securely.
• Attach the front cover and tighten the retaining screws.
The WH36 requires three independent 220/240V AC circuits
protected by three separate and independent double pole
circuit breakers (as shown) rated at 60 amps each.
Fig. 6 WH36 terminal block connection (for the U.S.A.)
As per the Canadian Electrical Code, C22.1-
02 Section 26-744, an auxiliary terminal
block must be fitted to the heater before
connecting to the electrical supply in
Canada.