Install Instructions
Table Of Contents
- Table of contents
- 1 Key to symbols and safety instructions
- 1.1 Key to symbols
- 1.2 Safety precautions
- 2 Information about the heater
- 3 Regulations
- 4 Installation
- 5 Operation instructions
- 6 Maintenance
- 7 Service
- 8 Troubleshooting
- 9 Spare Parts
- 10 Environment / disposal
- Indice
- 1 Explicación de la simbología y instrucciones de seguridad
- 1.1 Explicación de los símbolos
- 1.2 Instrucciones Importantes de Seguridad
- 2 Información sobre el calentador
- 3 Reglamentos
- 4 Instalación
- 5 Instrucciones de funcionamiento
- 6 Mantenimiento
- 7 Problemas
- 8 Piezas de repuesto
- 9 Protección del medio ambiente/reciclaje
- Sommaire
- 1 Explication des symboles et mesures de sécurité
- 1.1 Explication des symboles
- 1.2 Importantes instructions de sécurité
- 2 Informations relatives au chauffe- eau
- 3 Règlementations
- 4 Installation
- 5 Instructions d'utilisation
- 6 Maintenance
- 7 Diagnostic de pannes
- 8 Liste des pièces de rechange
- 9 Protection de l’environnement/ Recyclage
6 720 647 022 (2014/06)Tronic 5000C
Installation | 13
4.6 Starting up
4.6.1 Checking for leaks and purging air
▶ Verify all circuit breakers supplying power to the water
heater are turned off.
▶ Open all hot water taps supplied by the water heater and
inspect all water connections for leaks.
▶ With all hot water taps still open, inspect each tap to ensure
all air in the lines has been purged out.
▶ With the air purged and taps still flowing, turn on all circuit
breakers supplying the water heater.
▶ Close all hot water taps and proceed to the next section.
4.6.2 Adjusting the temperature dial
▶ The temperature adjustment is made using the dial on the
bottom edge of the unit. The adjustment is between
approximately 95 °F and 131 °F. Turning the dial clockwise
increases the temperature setting as indicated by the
marking on the unit.
4.6.3 OPTIONAL: Adjusting the flow
▶ Confirm hot water temperature setting is acceptable at a
sink.
▶ Open fully both inlet and outlet shut-off valves at the
heater, then:
▶ Turn on fully the highest flowing hot water fixture (e.g.,
bathtub) served by the water heater.
▶ If the water temperature is not hot enough, adjust the outlet
shut-off valve until the temperature is acceptable. Use
Fig. 8 below for reference if you know your maximum flow.
Fig. 8
These figures are based on an inlet water temperature of 55 °F
and a supply voltage of 240 volts. If the inlet water temperature
is lower than 55 °F, or if the supply voltage is less than 240
volts, then the flow rate for the shown temperatures will be
reduced shown in Fig. 8. If a higher outlet water temperature is
desired, then reduce the flow rate and/or supply the unit with
240 volts.
95 100 105 110 130115 120 125 135
2.50
Outlet temperature (ºF)
Max Flow Rate (US gal/min)
Outlet temperature vs Maximum flow rate setting
(based on incoming water temperature of 55ºF)
6720647022-03.1V
3.00
3.50
4.00
4.50
5.00
5.50
6.00
6.50
131
Before leaving the site, the installer should
demonstrate the unit to the user and give
them this guide.