Installation Guide

6 720 810 560 (2016/06)Optiflow Professional
Product details | 11
Flue condensate collector
We advise using a condensate trap when the flue length and the
lowest average inlet air temperature is likely to result in
condensate forming during operation.
When the intersection of the flue length and lowest average
inlet air temperature is in the white section of the graph, a
condensate trap is required. (See Fig. 4)
Fig. 4
[A] Flue pipe length
[B] Lowest average inlet air temperature
Bosch 4000S flue components
All 4000S coaxial flue components have an internal pipe
diameter of 60 mm and an external pipe diameter of 100 mm.
--- Flue Elbow Ø 60/100 90° 7 736 995 079
--- Flue Elbow Ø 60/100 45° 7 736 995 071
--- Flue Terminal Extension DN60/100 350mm 7 736 995 059
--- Flue Terminal Extension DN60/100 750 mm 7 736 995 063
--- Flue Terminal Extension DN60/100 1500 mm 7 736 995 067
--- Horizontal Condensate Trap Ø 60/100 7 736 995 087
--- Vertical Flue Condensate Trap Ø 60/100 7 736 995 089
Type Description Reference
Table 6 Flue gas accessories Ø60/100 mm
Add note on using 100m 2 pce clips.
(A)
10 m
9 m
7 m
6 m
8 m
5 m
4 m
3 m
2 m
1 m
0 m
0°C-5°C-10°C 5°C 10°C 15°C 20°C 25°C
(B)
6720809968-04.3V