Use and Care Manual

Product Specifi cations Bosch IDS BVA | 9
Bosch Thermotechnology Corp. | 12.2016
Data subject to change
6 Heater Kit Data
Heat Kit Model
Air Handler
Model
(kW)Electric Heat
MIN. Circuit Ampacity (Amps)
MAX.Fuse or Breaker (HACR)
Ampacity (Amps)
Fan speed
240 VAC 208 VAC 240 VAC 208 VAC 12345
WEHK05A
24
5 28.5 24.9 30 25 ●●●●●
WEHK08A 7.5 41.5 36.3 45 40 χ χ
WEHK10A 10 54.5 47.6 60 50 χ χ
WEHK05A
36
5 29.7 26.2 30 30 ●●●●●
WEHK08A 7.5 42.7 37.5 45 40 χ ●●●●
WEHK10A 10 55.8 48.8 60 50 χ χ
WEHK15B 15
55.8+26.1 48.8+22.6 60+30 50+25
χ χ ●●●
81.8 * 75.3 * 90 * 80 *
WEHK05A
48
5 33.6 30.1 35 35 ●●●●●
WEHK08A 7.5 46.6 41.4 50 45 ●●●●●
WEHK10A 10 59.6 52.7 60 60 χ ●●●●
WEHK15B 15
59.6+26.1 52.7+22.6 60+30 60+25
χ χ ●●●
85.7 * 75.3 * 90 * 80 *
WEHK20B 20
59.6+52.1 52.7+45.2 60+60 60+50
χχχ
111.7 * 97.8 * 125 * 100 *
WEHK05A
60
5 33.6 30.1 35 35 χ χ
WEHK08A 7.5 46.6 41.4 50 45 χ χ
WEHK10A 10 59.6 52.7 60 60 χ χ
WEHK15B 15
59.6+26.1 52.7+22.6 60+30 60+25
χ χ ●●●
85.7* 75.3* 90 * 80 *
WEHK20B 20
59.6+52.1 52.7+45.2 60+60 60+50
χχχ
111.7 * 97.8 * 125 * 100 *
Table 4
● - means available
χ - means not available
* - means single circuit
Electric Heater kit suitable for AHU multi position installation.
Model Description 24 36 48 60
WEHK05A 5kW Heat Kit,Double Pole Breaker ●●●●
WEHK08A 7.5kW Heat Kit,Double Pole Breaker ●●●●
WEHK10A 10kW Heat Kit,Double Pole Breaker ●●●●
WEHK15B 15kW Heat Kit,Double Pole Breaker X
WEHK20B 20kW Heat Kit,Double Pole Breaker X X
Table 11
● - means available
χ - means not available