Tradition of quality and innovation name has stood for quality and reliability. Bosch Security Systems 2007 For over 100 years, the Bosch proudly offers a wide range of fire, intrusion, social alarm, CCTV, systems and components to help you find the solution for any application. We are the global supplier of choice for innovative technology backed by the highest level of service and support. When you need solutions you can rely on, choose Bosch.
Control Panels, Control Centers, and Keypads 1 Accessories for Control Panels and Keypads 2 Software 3 Arming Devices 4 Detectors and Accessories 5 LSN Peripherals 6 Conettix - Information Transport Solutions 7 Wireless Local Security Network (wLSN) 8 DSRF Premises Wireless 9 Signaling Devices www.boschsecurity.com 10 Bosch Security Systems B.V.
Bosch Security Systems B.V. www.boschsecurity.
Table of Contents | i Control Panels, Control Centers, and Keypads 1 Easy Series Easy Series Intrusion Control Panel IUI‑EZ1 Oval Control Center ICP‑EZM2‑EU Intrusion Control Panel ICP‑EZM2‑UK Intrusion Control Panel ICP‑EZM2‑LC Intrusion Control Panel ITS-300GSM Communicator ICP‑EZPS‑FRA AFNOR Power Supply ICP‑EZPS Wire‑in Power Supply ICP‑EZPK Programming Key Easy Series Voice Modules 2 2 9 10 10 11 12 14 15 15 16 Solution Series CC408 Solution 880 Control Panel CC488 Solution Ultima 880 Control Pane
ii | Table of Contents Detectors and Accessories 135 DS484Q and DS486Q Quad‑Beam Photoelectric Detectors 228 Motion PIR ISC‑PPR1‑W16 Professional Series PIR Detector ISC‑PPR1‑WA16x Professional Series PIR Detectors with Anti‑mask ISM‑BLP1 Blue Line PIR Detector ISM‑BLP1‑P Blue Line Pet‑Friendly PIR Detector ISM‑BLQ1 Blue Line Quad PIR Detector DS306E PIR Detector DS308EA Quad PIR Detector with Anti-mask MX775i Multiplex PIR Intrusion Detector MX934i Multiplex PIR Intrusion Detector DS304 PIR Detector w
Table of Contents | iii ISM‑BLA1‑SM Blue Line Sounder Module B328 Gimbal‑mount Bracket Swiveling B335-3 low-profile mount B800 Ceiling‑mount Bracket DS1110i Glassbreak Tester MP1 Metal Pole, 1 m (3 ft) MP2 Metal Pole, 1.
iv | Table of Contents wLSN wLSN wLSN wLSN wLSN PIR Motion Detector Key Fob Mini Door‑Window Contact Recessed Door‑Window Contact Water Sensor/Low‑temperature Sensor wLSN Accessories wLSN Installation Tool DSRF Premises Wireless 447 450 452 454 456 458 458 461 Bosch DSRF Receivers RF3212 Series RF Receivers RF3222E RF Receiver (433.42 MHz) RF3227E RF Receiver (433.
1 Control Panels, Control Centers, and Keypads Easy Series www.boschsecurity.com 2 Solution Series 20 DS7080i 35 7000 Line 38 UEZ 2000 59 NZ 300 63 Bosch Security Systems B.V.
2 | Control Panels, Control Centers, and Keypads | Easy Series 1 Easy Series Intrusion Control Panel System Overview Features ▶ Supports up to 32 total input points (hard-wired, wireless, or combination) ▶ Advanced false alarm reduction ▶ Integrated proximity reader ▶ Speaks language of choice ▶ wireless Local SecurityNetwork (wLSN) support ▶ Remote Programming Software (RPS) support ▶ Simple icon-based control center ▶ Integrated digital dialer, voice dialer, text messaging, and two-way audio verificat
Control Panels, Control Centers, and Keypads | Easy Series | 3 Functions Certifications and Approvals Advanced False Alarm Reduction The Easy Series Intrusion Control Panel system guards against user-generated false alarms through design features such as Graduated Annunciation and Intelligent Threat Assessment. Easy Series uses enhanced false alarm verification methods that exceed industry false alarm reduction standards.
4 | Control Panels, Control Centers, and Keypads | Easy Series 1 Installation/Configuration Notes Input Points Compatibility Information Maximum Number of Input 32 Points: PSTN Communicator Formats: BSIA Fast Format, Contact ID, SIA, (Integrated) (Voice Dialer) Personal Messaging: SMS Text and Voice IP Communicator1, 3 Conettix IP C900V2 Dialer Capture Module GSM Communicator1, 3 Conettix ITS-300GSM Communicator Radio CommunicaSC2104 Series Slave Communicators tors (SAFECOM) 1, 2 SC3100 Series Data
Control Panels, Control Centers, and Keypads | Easy Series | 5 wLSN Kit 1 Ordering Information Europe, Middle East, and Africa Easy Series Kit Ordering Information Europe, Middle East, and Africa British English ICP‑EZ2AWT‑02 ICP‑EZV2‑ENUKF Turkish ICP‑EW1AWT‑19 ICP‑EZ2AWT‑19 German ICP‑EZ2AWT‑03 ICP‑EZV2‑DEF Arabic ICP‑EW1AWT‑21 ICP‑EZ2AWT‑21 Dutch ICP‑EZ2AWT‑04 ICP‑EZV2‑NLF Romanian ICP‑EW1AWT‑29 ICP‑EZ2AWT‑29 Hungarian ICP‑EZ2AWT‑05 ICP‑EZV2‑HUF Czech ICP‑EZ2AWT‑06 ICP‑EZV2‑CSF
6 | Control Panels, Control Centers, and Keypads | Easy Series 1 2Requires a separately purchased voice module, power supply, and enclosure for operation. Easy Series Kit Ordering Information United States Kits include one control panel, enclosure, oval control center, plug‑in power supply (110 V for US), and two RFID tokens unless noted otherwise.
Control Panels, Control Centers, and Keypads | Easy Series | 7 Ordering Information Ordering Information ICP-EZ2AWT-09 Spanish [European] Easy Series Kit with Ta mper Switch Appropriate for use in Europe, the Middle East, and Africa. One control panel with Spanish [European] female voice module, tamper switch, wire-in power supply, enclosure, oval control center, and two tokens.
8 | Control Panels, Control Centers, and Keypads | Easy Series 1 Ordering Information Ordering Information ICP-EZ2AWT-31 Slovenian Easy Series Kit with Tamper Swit ch Appropriate for use in Europe, the Middle East, and Africa. One control panel with Slovenian female voice module, tamper switch, wire-in power supply, enclosure, oval control center, and two tokens. ICP-EZ2AWT-31 ICP-EZ2AWT-32 Serbian Easy Series Kit with Tamper Switch Appropriate for use in Europe, the Middle East, and Africa.
Control Panels, Control Centers, and Keypads | Easy Series | 9 IUI‑EZ1 Oval Control Center The user interface for the Easy Series Intrusion Control Panel. It speaks in your local language while showing animated, color-coded icons on the screen to reinforce the spoken words. It includes a speaker and a microphone; the speaker projects tones and speaks instructions, you use the microphone to speak with monitoring facility personnel.
10 | Control Panels, Control Centers, and Keypads | Easy Series 1 ICP‑EZM2‑EU Intrusion Control Panel ICP‑EZM2‑UK Intrusion Control Panel Certifications and Approvals Certifications and Approvals Region Certification Region Certification Europe CE 1999/5/EC, 2006/95/EC, 2004/108/ EC; EN 55022:2006 + A1:2007, Class B; EN 50130-4 w/A1:1998 + A2:2003; EN61000-3-2:2006; EN61000-3-3:1995; EN 60950-1:2001; TBR21:1998 Europe CE Sweden INTYG Centralapparat - trådlös: Nr08-424 Centralapparat: Nr08-4
Control Panels, Control Centers, and Keypads | Easy Series | 11 ICP‑EZM2‑LC Intrusion Control Panel 1 Certifications and Approvals Region Certification Europe CE 1999/5/EC, 2006/95/EC, 2004/108/ EC; EN 55022:2006 + A1:2007, Class B; EN 50130-4 w/A1:1998 + A2:2003; EN61000-3-2:2006; EN61000-3-3:1995; EN 60950-1:2001; TBR21:1998 Ordering Information ICP‑EZM2‑LC Intrusion Control Panel One control panel printed circuit board without an enclosure. www.boschsecurity.
12 | Control Panels, Control Centers, and Keypads | Easy Series 1 ITS-300GSM Communicator Features ▶ Monitoring of the telephone line statically and dynamically ▶ Backup path transmission via the GSM network in the event of a fault in the telephone line ▶ Calls from house phone via the GSM network are possible System Overview (1) House phone (2) Control panel (3) ITS-300GSM (4) Analog telephone network (5) GSM mobile network (6) Telephone network receiver (7) SMS receiver (8) Cell phone (A) Outgoing ca
Control Panels, Control Centers, and Keypads | Easy Series | 13 Transmission of own events If necessary, the device can transmit test calls and fault/ restoration of telephone line as an SMS message. Voltage range 10 to 14 V DC Dimensions 12.5 x 7 cm 1 Programming Programming is carried out with a cell phone via entries on the SIM card. In transparent transmission, no programming is necessary for standard applications. Remote programming is possible with a cell phone via SMS messages.
14 | Control Panels, Control Centers, and Keypads | Easy Series 1 ICP‑EZPS‑FRA AFNOR Power Supply Technical Specifications Primary Voltage Input (AC): 110 V +10/-15% (60 Hz) 230 V +10/-15% (50 Hz) Ordering Information ICP‑EZPS‑FRA AFNOR Power Supply For use in France. Provides 14 VDC and isolated auxiliary power outputs. Bosch Security Systems B.V. ICP-EZPS-FRA www.boschsecurity.
Control Panels, Control Centers, and Keypads | Easy Series | 15 ICP‑EZPS Wire‑in Power Supply ICP‑EZPK Programming Key For use in Europe, the Middle East, Asia Pacific, Central and South America. 100 VAC to 240 VAC primary voltage input (AC).
16 | Control Panels, Control Centers, and Keypads | Easy Series 1 Easy Series Voice Modules Easy Series voice modules allow the IUI-EZ1 Oval Control Center to provide spoken instructions and information. Bosch offers voice modules in 34 languages. Each voice module uses a female voice. For ultimate flexibility, specific Easy Series kits do not include voice modules. The voice module in a preferred language can be ordered separately and used in the system. Bosch Security Systems B.V. www.boschsecurity.
Control Panels, Control Centers, and Keypads | Easy Series | 17 System Overview www.boschsecurity.com 1 Bosch Security Systems B.V.
18 | Control Panels, Control Centers, and Keypads | Easy Series 1 Ordering Information Ordering Information Arabic Voice Module Arabic language module programmed with a female voice. Works as part of the Easy Series Intrusion Control Panel system to provide spoken instructions and information. ICP-EZV2-ARF Greek Voice Module Greek language module programmed with a female voice. Works as part of the Easy Series Intrusion Control Panel system to provide spoken instructions and information.
Control Panels, Control Centers, and Keypads | Easy Series | 19 Ordering Information Swedish Voice Module Swedish language module programmed with a female voice. Works as part of the Easy Series Intrusion Control Panel system to provide spoken instructions and information. ICP-EZV2-SVF Turkish Voice Module Turkish language module programmed with a female voice. Works as part of the Easy Series Intrusion Control Panel system to provide spoken instructions and information. ICP-EZV2-TRF www.boschsecurity.
20 | Control Panels, Control Centers, and Keypads | Solution Series 1 CC408 Solution 880 Control Panel AWAY Mode: Arms the entire system. STAY Mode 1: Arms most zones. Does not arm zones programmed as isolated (installer). STAY Mode 2: Arms most zones. Does not arm zones programmed as isolated (Master Code holder). Dual-tone Multi-frequency (DTMF) Telephone Remote Arming Users can arm the system from any remote location using a DTMF telephone.
Control Panels, Control Centers, and Keypads | Solution Series | 21 Programmable Ring Burst Time Telephone ring times might be longer or shorter depending on the technology in a system. Different timing can cause control panels to answer calls that should be answered by an answering machine, fax, or a person. Users can program the control panel for the correct ring burst time. Adjust the ring time by 5 ms up to a total of 75 ms, or by 80 ms up to a total of 1200 ms.
22 | Control Panels, Control Centers, and Keypads | Solution Series 1 CC488 Solution Ultima 880 Control Panel Remote Programming Users can program the zones remotely with CC816 Alarm Link (A-Link) software on a PC with MS-DOS® and a modem. Users can run diagnostics, arm systems, and bypass zones with an off-site computer. This reduces service visits to a site and provides quick customer service, saving time and money.
Control Panels, Control Centers, and Keypads | Solution Series | 23 Automatic Battery Testing The system performs a battery test each time a user arms the sys-tem, and automatically every four hours. When the system detects a low capacity back-up battery, it creates a low battery fault. Event Memory Recall Event Memory Recall plays the last 40 system events, including all alarms, system arming, and system disarming. If the control panel is partitioned, Event Memory Recall plays the last 10 system events.
24 | Control Panels, Control Centers, and Keypads | Solution Series 1 CC880 Solution 16 Control Panel Four Areas The control panel is partitioned into four areas. One master codepad or multiple separate area addressable codepads can operate each area. Remote Programming Users can program the zones remotely with CC816 Alarm Link (A-Link) software on a PC with MS-DOS® and a modem. Users can run diagnostics, arm systems, and bypass zones with an off-site computer.
Control Panels, Control Centers, and Keypads | Solution Series | 25 Event Memory Recall Event Memory Recall plays the last 40 system events, including all alarms, system arming, and system disarming. If the control panel is partitioned, Event Memory Recall plays the last 10 system events.
26 | Control Panels, Control Centers, and Keypads | Solution Series 1 Ordering Information CC880P Solution 16 Control Panel Includes assembled printed circuit board (PCB), power connector, EOL resistors, terminals, battery leads, and spare fuses. CC880P CC880PSP Solution 16 Control Panel Includes assembled printed circuit board (PCB), power connector, EOL resistors, terminals, battery leads, and spare fuses. Has a programmable ring burst time option.
Control Panels, Control Centers, and Keypads | Solution Series | 27 VR8 Desktop Alarm System Programming Program the VR8 System using the integrated keypad, a laptop, a plug-in programming key for standard programs, or compatible programming software. Zone Types Users can configure three zone types for the system. Zone Type Description Burglary Sounds an alarm when a fault is detected and the VR8 is armed. 24-Hour Sounds an alarm when a fault is detected, such as a tamper switch.
28 | Control Panels, Control Centers, and Keypads | Solution Series 1 Technical Specifications Data Bus Internal ports for auxiliary and programming modules Enclosure Design Color: White Indicators: Eight zone LCD display Material: ABS Dimensions: 20.8 cm x 25.5 cm x 8.4 cm (8 in. x 10 in. x 3 in.
Control Panels, Control Centers, and Keypads | Solution Series | 29 CP500ALW Area Addressable LCD Codepad • Method #2: Hold down the AWAY button for two seconds. The AWAY indicator will display. For further details on codepad operation please see the Solution panels listed in the Install and Configuration Notes, and then refer to the appropriate Operator Guide for the panel. To disarm the system in AWAY mode, enter the user code followed by the AWAY button.
30 | Control Panels, Control Centers, and Keypads | Solution Series 1 CP500AW Area Addressable LED Codepad • Method #2: Hold down the AWAY button for two seconds. The AWAY indicator will display. For further details on codepad operation please see the Solution panels listed in the Install and Configuration Notes, and then refer to the appropriate Operator Guide for the panel. To disarm the system in AWAY mode, enter the user code followed by the AWAY button.
Control Panels, Control Centers, and Keypads | Solution Series | 31 CP500PW Partitionable LED Codepad The back DIP switches can be set to select the codepad area. For further details on codepad operation please see the Solution panels listed in the Install and Configuration Notes, and then refer to the appropriate Operator Guide for the panel. To disarm the system in AWAY mode, enter the user code followed by the AWAY button.
32 | Control Panels, Control Centers, and Keypads | Solution Series 1 CP508W LED Codepad The AWAY indicator will display. For further details on codepad operation please see the Solution panels listed in the Install and Configuration Notes, and then refer to the appropriate Operator Guide for the panel. To Disarm the system in AWAY mode: • Enter the user code followed by the AWAY button.
Control Panels, Control Centers, and Keypads | Solution Series | 33 CP516LW LCD Codepad The AWAY indicator will display. For further details on codepad operation please see the Solution panels listed in the Install and Configuration Notes, and then refer to the appropriate Operator Guide for the panel. To Disarm the system in AWAY mode: • Enter the user code followed by the AWAY button.
34 | Control Panels, Control Centers, and Keypads | Solution Series 1 CP516W LED Codepad For further details on codepad operation please see the Solution panels listed in the Install and Configuration Notes, and then refer to the appropriate Operator Guide for the panel. To disarm the system in AWAY mode, enter the user code followed by the AWAY button.
Control Panels, Control Centers, and Keypads | DS7080i | 35 DS7080iP32 Eight-zone Control Panels Two Partitions The DS7080iP-32 can be split into two partitions. Assign users to one or both partitions. Program common zones to allow users access to areas (foyers and entrance ways). Partitions and common zones can be accessed by assigned users from all keypads. 24 PINs Supports 24 PINs in any combination of four or six digits. Designate PINs as master PINs that can be used to reprogram PINs.
36 | Control Panels, Control Centers, and Keypads | DS7080i 1 Program Memory The control panel retains all program memory and the armdisarm state during a power failure. When power restores, alarms are delayed to prevent false alarms from detectors that can take several minutes to become operational. None of the system programming or user codes are lost. Certifications and Approvals Region Certification Europe CE 1999/5/EC, EN60950 Dec.
Control Panels, Control Centers, and Keypads | DS7080i | 37 Fire Signal Initiating Circuit (Two-Wire Mode) Circuit Type: Class B, latching Supervisory Current: 5 mA Circuit Voltage: 8.5 VDC to 14.1 VDC Circuit Resistance: 60 Ω maximum Current for Alarm: 12 mA minimum Impedance for Alarm: 1000 Ω maximum Short Circuit Current: 22 mA maximum Detector Standby Current: 2.
38 | Control Panels, Control Centers, and Keypads | 7000 Line 1 DS7220V2 Control Panel System Overview Features ▶ Eight on-board zones ▶ Eight programmable Skeds ▶ RF compatibility ▶ Up to 32 users with optional keyfob operation available ▶ Four programmable authority levels ▶ Two communications routing destinations ▶ 254 event log ▶ Remote-programmable with RPS-INTL ▶ Optional Door Access Control Module (DACM) ▶ Network communication option (LAN/WAN) The DS7220V2 has eight zones expandable to 24, four
Control Panels, Control Centers, and Keypads | 7000 Line | 39 Eight On-board Zones Flexible Digital Communications The DS7220V2 Control Panel has eight on-board zones. It can have hard-wired expanded zones and wireless zones. Program any of these zones to follow one of 15 zone functions. The DS7220V2 Control Panel works with most alarm receivers that support Contact ID and SIA 300 digital communicator formats and pager format.
40 | Control Panels, Control Centers, and Keypads | 7000 Line 1 PO 2: can be used with Alarm + as a supervised siren driver. Connect an approved 4 Ω or 8 Ω speaker. Alternatively, PO 2 can sink up to 500 mA, 12 VDC. Batteries D126 12 V, 7 Ah Standby Battery RF3227E RF Receiver RF3332E Two-button Keyfob PO 3 and PO 4: can be configured for Alarm Output. These outputs can sink 500 mA, 12 VDC each.
Control Panels, Control Centers, and Keypads | 7000 Line | 41 Keypads and Door Access Control Module (DACM) Number supported: 1 8 maximum in any combination of keypads or DACMs Power Outputs Continuous Power: 1.2 A maximum Alarm Power: 1.85 A maximum at 11.5 VDC to 12.
42 | Control Panels, Control Centers, and Keypads | 7000 Line 1 DS7240V2 Control Panel System Overview Features ▶ Eight on-board zones ▶ Eight programmable Skeds ▶ RF compatibility ▶ Up to 32 users with optional key fob operation available ▶ Four programmable authority levels ▶ Two communications routing destinations ▶ 254 event log ▶ Remote-programmable with RPS ▶ Optional Door Access Control Module (DACM) ▶ Network communication option (LAN/WAN) The DS7240V2 Control Panel has eight zones expandable t
Control Panels, Control Centers, and Keypads | 7000 Line | 43 Eight On-board Zones Flexible Digital Communications The DS7240V2 Control Panel has eight on-board zones. It can have hard-wired expanded zones and wireless zones. Program any of these zones to follow one of 15 zone functions. The DS7240V2 Control Panel works with most alarm receivers that support Contact ID and SIA 300 digital communicator formats and pager format.
44 | Control Panels, Control Centers, and Keypads | 7000 Line 1 Outputs DS250TH Photoelectric Smoke Detector with heat-sensing thermistor The DS7240V2 has four on-board programmable outputs that may be expanded up to 20. DS284 Photoelectric Smoke Detector DS284TH Photoelectric Smoke Detector with heat-sensing thermistor PO 1: terminals can be configured as an alarm power output. The default configuration for PO 1 makes it a dry contact, Normally-Open (NO) relay.
Control Panels, Control Centers, and Keypads | 7000 Line | 45 Enclosure Material: 1.0 mm, cold-rolled steel Dimensions: 36.8 cm x 31.8 cm x 7.6 cm (14.5 in. x 12.5 in. x 3 in.) 1 Environmental Considerations Relative Humidity: 5% to 85% at +30°C (+86°F) non-condensing Temperature (Operating): 0°C to +49°C (+32°F to +120°F) Keypads and Door Access Control Module (DACM) Number supported: 8 maximum in any combination of keypads or DACMs Power Outputs Continuous Power: 1.
46 | Control Panels, Control Centers, and Keypads | 7000 Line 1 DS7400Xi Series Addressable Control Panels Custom Arming Configurations Program the system to arm in different configurations to automatically bypass a group of zones. Easy Function Key User Interface • Six labeled function keys eliminate the need for multibutton commands. Enter a PIN followed by the function key to perform functions such as arming, disarming, and resetting smoke detectors.
Control Panels, Control Centers, and Keypads | 7000 Line | 47 Octal Relay Modules The DS7400Xi Series Control Panels support up to two DX3010 Octo-Output Expander Modules. Each module supplies eight relay or solid state outputs to follow system events or to follow programmed Output Functions from the control panel.
48 | Control Panels, Control Centers, and Keypads | 7000 Line 1 Fire Signal Initiating Circuit Ordering Information Fire circuits will work with two-wire or four-wire detectors and have optional alarm verification. DS7400XI-FI Control Panel For use in Finland. DS7400XI-FI Number of Circuits: 8 circuits on board, expandable to 16 DS7400XI-FRA Type of Circuit: Class B, latching DS7400XI-FRA Control Panel For use in France. End of Line Resistor: 2.
Control Panels, Control Centers, and Keypads | 7000 Line | 49 DS7446KP Series LCD Keypads Programmable Keys Each DS7446KP Keypad model has 19 illuminated keys for specific functions. Your installing company can program the [A], [B], and [C] keys with functions such as Emergency, Fire, or Panic. When pressed, each key emits a muted beep. Adjustable Volume You can adjust the keypad volume. When the sounder is active, pressing any key on the keypad momentarily silences the sounder.
50 | Control Panels, Control Centers, and Keypads | 7000 Line 1 Ordering Information DS7446KP‑EX LCD Keypad For export. Provides volume controls and three programmable emergency keys. DS7446KP-EX DS7446KP‑SE LCD Keypad For use in Sweden. Provides volume controls and three programmable emergency keys. DS7446KP-SE DS7446KP‑FR LCD Keypad For use in France. Provides volume controls and three programmable emergency keys. DS7446KP-FR DS7446KP‑NL LCD Keypad For use in the Netherlands.
Control Panels, Control Centers, and Keypads | 7000 Line | 51 DS7447V2 Series LCD Keypads Certifications and Approvals Region Certification Europe CE 1 1999/5/EC, 2006/95/EC, 2004/108/ EC; EN 55022:2006 + A1:2007, Class B; EN 50130-4 w/A1:1998 + A2:2003; EN61000-3-2:2006; EN61000-3-3:1995; EN 60950-1:2001; TBR21:1998 89/336/EEC, EN55022: 1998, EN50130-4: 1995, EN60950: 2000, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11 Belgium Features ▶ Ad
52 | Control Panels, Control Centers, and Keypads | 7000 Line 1 Power Requirements Ordering Information Current Draw: 95 mA idle; 200 mA max (with speaker volume and backlight brightness on) Voltage (Operating): 12 VDC Product Characteristics Dimensions: 12 cm x 21 cm x 2 cm (4.6 in. x 8.2 in. x 0.8 in.) Weight: 439 g (15.5 oz) Ordering Information DS7447V2‑EXP LCD Keypad For export.
Control Panels, Control Centers, and Keypads | 7000 Line | 53 DS7447E Series LCD Keypads Certifications and Approvals Region Certification Europe CE 1999/5/EC, 2006/95/EC, 2004/108/ EC; EN 55022:2006 + A1:2007, Class B; EN 50130-4 w/A1:1998 + A2:2003; EN61000-3-2:2006; EN61000-3-3:1995; EN 60950-1:2001; TBR21:1998 DS7447E: 89/336/EEC, EN55022: 1998, EN50130-4: 1995, EN60950: 2000, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11 USA UL Features
54 | Control Panels, Control Centers, and Keypads | 7000 Line 1 • Multiple Keypad Use in Commercial Fire Systems: One keypad must be used on the keypad bus and must be assigned as keypad address 1. It can be mounted on the front of the control enclosure. If it is not mounted on the front of the control enclosure, you must mount it in the same room as and within 6 m (20 ft) of the control equipment, and run the wire in conduit or provide equivalent protection against mechanical damage.
Control Panels, Control Centers, and Keypads | 7000 Line | 55 DS7445V2 Series LED Keypads Certifications and Approvals Region Certification Europe CE 1 89/336/EEC, EN55022: 1998, EN50130-4: 1995, EN60950: 2000, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11 1999/5/EC, 2006/95/EC, 2004/108/ EC; EN 55022:2006 + A1:2007, Class B; EN 50130-4 w/A1:1998 + A2:2003; EN61000-3-2:2006; EN61000-3-3:1995; EN 60950-1:2001; TBR21:1998 Belgium INCERT DS744
56 | Control Panels, Control Centers, and Keypads | 7000 Line 1 Technical Specifications Environmental Considerations Relative Humidity: 5% to 93% at +32°C (+90°F), non-condensing Temperature (Operating): 0°C to +50°C (+32°F to +122°F) Power Requirements Current Draw: 95 mA idle; 200 mA max (with speaker volume and backlight brightness on) Voltage (Operating): 12 VDC Product Characteristics Dimensions: 12 cm x 21 cm x 2 cm (4.6 in. x 8.2 in. x 0.8 in.) Weight: 439 g (15.
Control Panels, Control Centers, and Keypads | 7000 Line | 57 DS7445i Series LED Keypads Certifications and Approvals Region Certification Europe CE 1999/5/EC, 2006/95/EC, 2004/108/ EC; EN 55022:2006 + A1:2007, Class B; EN 50130-4 w/A1:1998 + A2:2003; EN61000-3-2:2006; EN61000-3-3:1995; EN 60950-1:2001; TBR21:1998 Belgium INCERT DS7445i: B-509-004/b Installation/Configuration Notes Compatibility Information Control Panel Number of Operating LEDs on DS7445V2 Keypad DS7080iP-32 and DS7400Xi Series
58 | Control Panels, Control Centers, and Keypads | 7000 Line used for the DS7420i Dual Phone Line/Bell Supervision Module. 1 Note On the DS7400Xi Control Panels, up to 11 keypads can be used in commercial fire mode. Install one keypad on the option bus and up to ten keypads on the keypad bus. Note When using multiple keypads in a commercial fire application, a UL Listed auxiliary power supply might be required.
Control Panels, Control Centers, and Keypads | UEZ 2000 | 59 UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers System Overview 1 Features ▶ Up to 6 UEZ LSNs can be networked with system loop technology (SRT) 1 External signaling devices 2 ATBL activation panel ▶ Fire alarm peripheral elements can be connected in the LSN loop 3 IUI-UEZ-BE1000s keypad 4 Priority Bosch control center ▶ 4 loop or 8 stub lines with UEZ 2000/1 LSN 5 Transmission unit (ÜE) ▶ Max.
60 | Control Panels, Control Centers, and Keypads | UEZ 2000 1 Message display and operation • The integrated operating unit (ADT) or a remote operating panel can be used to process incoming messages and operate the system. Internal and external expansion options Saving messages A log printer can be integrated to record messages. Up to 1000 events can be stored in an event database.
Control Panels, Control Centers, and Keypads | UEZ 2000 | 61 SRT system parameters Maximum number of detector zones Signaling devices 32 per system, max.
62 | Control Panels, Control Centers, and Keypads | UEZ 2000 1 Parts Included External signaling devices Qty. UEZ 2000/1 LSN UEZ 2000 LSN 1 AVM 010 Connection of the lines and internal connection board of ZVM 100, LVM 100, SEMO1, ASE, RTP, TRN, SM 20 and SM 485 modules AVM 100 Connection board for connecting all detector and peripheral elements and internally linking the ZVM 100, LVM 100.
Control Panels, Control Centers, and Keypads | NZ 300 | 63 NZ 300 LSN Hold-up and Intrusion Control Panel System Overview 1 Features ▶ 8 detection areas 1 Telephone network ▶ 8 keypads 2 Transmission unit ▶ 4 inter programs 3 External signaling device ▶ 1 LSN loop or 2 LSN stubs with 127 LSN elements and up to 140 detector addresses 4 Configuration PC E LSN element ▶ Identification of individual detectors ▶ All connected switch outputs freely programmable ▶ Simple programming with NzPara ▶
64 | Control Panels, Control Centers, and Keypads | NZ 300 1 • The NZ 300 LSN is equipped with an event database for the last 1024 events. All alarms, malfunctions, deactivations and control panel resets are stored. The events, which are saved together with the date and time, can be shown on the display of the BE 300 LSN or using a PC. In addition, a print-out can be produced via a PC.
Control Panels, Control Centers, and Keypads | NZ 300 | 65 Switch output fault relay Environmental conditions • Ambient temperature (in operation) -5 °C to +45 °C • Principle Zero potential operating contact • Storage and transport temperature -20 °C to +60 °C Contact load 30 W/1 A Environmental class II (VdS 2110) • • Activation time 3–180 sec, continuous Housing protection category IP 40 • • Electromagnetic compatibility (EMC) • • Interference immunity DIN EN 50130-4 Interference
66 | Control Panels, Control Centers, and Keypads | NZ 300 1 BE 300 LSN remote operating unit Housing • • Material ABS Color RAL 9010 Dimensions (H x W x D) 112 x 162 x 29 mm Weight 0.25 kg Ordering Information BE 300 LSN remote operating unit For displaying and executing operating states and functions of the NZ 300 LSN 4998031457 The BE 300 LSN keypad acts as a remote display/control panel for the NZ 300 LSN. The BE 300 LSN is integrated into an LSN loop or LSN stub.
2 Accessories for Control Panels and Keypads www.boschsecurity.com Expansion Modules 68 Interface Modules 82 Door Access Control Modules 91 Enclosures 98 Power Supplies and Batteries 100 Cables, Switches, and Programmers 110 Control Center and Keypad Accessories 111 Bosch Security Systems B.V.
68 | Accessories for Control Panels and Keypads | Expansion Modules 2 DX2010 Series Input Expander Installation/Configuration Notes Compatibility Information Control Panels Easy Series (ICP‑EZM2‑NA, ICP‑EZM2‑UK, ICP‑EZM2‑LC), D4412, D6412, DS7220V2, and DS7240V2 Technical Specifications Outputs Outputs: 100 mA, 12 VDC supervised output for accessories Environmental Considerations Operating Temperature: 0°C to +50°C (+32°F to +122°F) Features Relative Humidity: 5% to 85% at +30°C (+86°F), non‑cond
Accessories for Control Panels and Keypads | Expansion Modules | 69 DX3010 Series Octo‑output Expander Installation/Configuration Notes Compatibility Information Control Panels D4412, D6412, and CC7240-A Technical Specifications Outputs Outputs: Dry contacts, rated 5.
70 | Accessories for Control Panels and Keypads | Expansion Modules 2 DS7430 Multiplex Expansion Module Installation/Configuration Notes Compatibility Information Control Panels DS7400Xi Series Powering Modules and Detectors The Bus Power output is for connection of separately powered multiplex devices, such as the DS7432 Eight-input Remote Module. If using separate powered detectors, they should be powered from the auxiliary power terminals of the control panel. Wiring Up to 610 m (2000 ft) of 0.
Accessories for Control Panels and Keypads | Expansion Modules | 71 DS7432 Series Eight‑input Remote Modules Installation/Configuration Notes Compatibility Information The DS7432 Series modules can only connect to the following control panels with an attached multiplex expansion module.
72 | Accessories for Control Panels and Keypads | Expansion Modules Technical Specifications Circuit Parameters 2 Initiating Device Type: Class B, Style A Signaling Line Circuit Type: Class B, Style 4 Environmental Considerations Temperature (operating): 0°C to +50°C (+32°F to +122°F) Power Requirements Current Draw: 10 mA maximum DS7432 EOL Resistor: 47 kΩ DS7432E EOL Resistor: 22 kΩ+47 kΩ per input Voltage: 12 VDC nominal Ordering Information DS7432E Eight‑Input Remote Module Includes ser
Accessories for Control Panels and Keypads | Expansion Modules | 73 DS7433 Series Eight‑input Modules Region Certification USA UL DS7433: AMCX: Central Station Alarm Units (UL1610, UL1635), AOTX: Local Alarm Units (UL464, UL609), APAW: Police Station Alarm Units (UL365, UL464), NBSX: Household Burglar Alarm System Units (UL1023), UTOU: Control Units and Accessories - Household System Type (UL985) NYC-MEA DS7433: 274-93-E, Vol. III 274-93-E, Vol. III DS7433: 274-93-E, Vol. IV 274-93-E, Vol.
74 | Accessories for Control Panels and Keypads | Expansion Modules 2 DS7436 Multiplex Expansion Module Powering Modules and Detectors The Bus Power output is for connection of separately powered multiplex devices, such as the DS7432 Eight-input Remote Module. If using separate powered detectors, they should be powered from the auxiliary power terminals of the control panel. Wiring Up to 610 m (2000 ft) of 0.8 mm (22 AWG) or 1525 m (5000 ft) of 1.2 mm (18 AWG) wire may be used for the multiplex loop.
Accessories for Control Panels and Keypads | Expansion Modules | 75 DS7457i Series Single Zone Input Modules Certifications and Approvals Region Certification Europe CE DS7457iF: 89/336/EEC, EN55022: 1998, EN50130-4: 1995, EN60950: 2000, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11 USA UL Both models: AMCX: Central Station Alarm Units (UL1610, UL1635), AOTX: Local Alarm Units (UL464, UL609), APAW: Police Station Alarm Units (UL365, UL464) D
76 | Accessories for Control Panels and Keypads | Expansion Modules Parts Included Quantity Component 2 1 Single-zone input module 1 Literature pack Technical Specifications Circuit Parameters Initiating Circuit Type (DS7457iF): Class B (Style A) Signaling Line Circuit Type: Class B (Style 4) Environmental Considerations Temperature (Operating): 0°C to +49°C (+32°F to +120°F) Power Requirements Current Draw: 0.
Accessories for Control Panels and Keypads | Expansion Modules | 77 DS7457iE Single Zone Input Module Wiring Considerations Refer to the intended control panel’s installation guide for multiplex wiring requirements. The recommended wiring to the control panel is four-wire 0.8 mm cable. Do not use shielded or twisted pair cable. Note The length of the wiring connected to the protection loop (and tamper loop) must be less than 76 m.
78 | Accessories for Control Panels and Keypads | Expansion Modules 2 DS7460i Dual‑zone Input Module Certifications and Approvals Region Certification Europe CE 89/336/EEC, EN55022: 1998, EN50130-4: 1995, EN60950: 2000, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11 USA UL NBSX: Household Burglar Alarm System Units (UL1023), UOXX: Control Unit Accessories, System (UL864, 9th edition), UTOU: Control Units and Accessories Household System Type
Accessories for Control Panels and Keypads | Expansion Modules | 79 Parts Included Quantity Component 1 Dual-zone input module 2 Multiplex-zone EOL resistor (P/N: 26069) 1 Hardware pack 1 Literature pack 2 Technical Specifications Circuit Parameters Initiating Device Circuit Type: Class B (Style A) Signaling Line Circuit Type: Class B (Style 4) Zone Requirements: Two multiplex addresses Environmental Considerations Temperature (Operating): 0°C to +50°C (32°F to +122°F) Power Requirements C
80 | Accessories for Control Panels and Keypads | Expansion Modules 2 DS7465i Input‑Output Module Certifications and Approvals Region Certification Europe CE 89/336/EEC, EN55022: 1998, EN50130-4: 1995, EN60950: 2000, EN61000-3-2, EN61000-3-3, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11 USA UL NBSX: Household Burglar Alarm System Units (UL1023), UOXX: Control Unit Accessories, System (UL864, 9th edition), UTOU: Control Units and Accessories Household System Type (U
Accessories for Control Panels and Keypads | Expansion Modules | 81 Parts Included Quantity Component 1 Input-output module 1 Multiplex-zone EOL resistor (P/N: 26069) 1 Hardware pack 1 Literature pack 2 Technical Specifications Circuit Parameters Initiating Device Circuit Type: Class B (Style A) Signaling Line Circuit Type: Class B (Style 4) Zone Requirements: One multiplex address Environmental Considerations Temperature (Operating): 0°C to +50°C (32°F to +122°F) Outputs Relay Contact Rat
82 | Accessories for Control Panels and Keypads | Interface Modules 2 Conettix DX4020 Ethernet Network Interface Module System Overview 1. Compatible Control Panel 2. Compatible Control Panel Option Bus or SDI Bus Connection 3. Conettix DX4020 Ethernet Network Interface Module 4. Ethernet Network Connection to DX4020 5. Host PC running Conettix D6200 Programming/Administration Software Features 6.
Accessories for Control Panels and Keypads | Interface Modules | 83 Certifications and Approvals Region Certification Europe CE USA 89/336/EEC, EN55022: 1997 +A2: 2002, EN50130-4: 1995 +A1: 1998 +A2: 2003, EN60950: 2000, EN61000-3-2: 2001, EN61000-3-3A1: 2001, EN61000-4-2: 1995 +A1: 1998 +A2: 2001, EN61000-4-3: 1996 +A1: 1998 +A2: 2000, EN61000-4-4: 1995 +A1: 2001 +A2: 2001, EN61000-4-5: 1995 +A1: 2001, EN61000-4-6: 1996 +A1: 2000, EN61000-4-11: 1994 +A1: 2001 UL AMCX: Central Station Alarm Units (U
84 | Accessories for Control Panels and Keypads | Interface Modules 2 Conettix C900V2 Dialer Capture Ethernet Module System Overview When the dialer has a message to report, the C900V2 simulates dial tone and line voltages, causing the dialer to behave as though it is connected to a monitoring center digital receiver through the PSTN. The C900V2 decodes and converts the transmitted dialer message to data for transport over any UDP/IP network.
Accessories for Control Panels and Keypads | Interface Modules | 85 Functions Polling and Supervision ADT-SIA Conettix C900V2 polling helps the Conettix D6600 Communications Receiver/Gateway to perform supervision.
86 | Accessories for Control Panels and Keypads | Interface Modules 2 Australia A-Tick Canada IC USA FCC Note Ordering Information Part 15 Radiated/Conducted Emissions FM approval applies when the C900V2 is used with the Conettix D6600 Communications Receiver/Gateway. Conettix C900V2 Dialer Capture Ethernet Module Compatible with control panels using a standard digital dialer format. Provides end-to-end security.
Accessories for Control Panels and Keypads | Interface Modules | 87 DX4010i RS‑232 Serial Interface Module System Overview 2 Features ▶ Transparent enclosure ▶ Diagnostic light emitting diodes (LEDs) ▶ RJ-16 data bus connector ▶ DIP switches for address and bus programming ▶ Enhanced direct connection for Remote Programming Software (RPS) ▶ DB9 DTE RS-232 connector The DX4010i RS-232 Serial Interface Module connects to: The DX4010i RS-232 Serial Interface Module creates a local connection between compa
88 | Accessories for Control Panels and Keypads | Interface Modules 2 Two Red LEDs Function BUS RX Data bus receives data from control panel BUS TX Data bus transmits data to control panel Two Green LEDs Function SER RX RS-232 receives data from serial device SER TX RS-232 transmits data to serial device Certifications and Approvals Region Certification Europe CE Australia 89/336/EEC, EN55022: 1994 +A1: 1995 +A2: 1997 Class A, EN50130-4: 1995 +A1: 1998 +A2: 2003, EN60950-1: 2001, EN61000-
Accessories for Control Panels and Keypads | Interface Modules | 89 DS7420i Dual Phoneline/ Bell Supervision Module Certifications and Approvals Region Certification Europe CE 89/336/EEC, EN55022: 1994 +A1: 1995 +A2: 1997 Class A, EN50130-4: 1995 +A1: 1998 +A2: 2003, EN60950-1: 2001, EN61000-3-2: 2000, EN61000-3-3: 1995 +A1: 2001 1999/5/EC, EN60950 Dec 1992 (2nd edition) +A1: 1992 +A2: 1993, EN50081-1: 1992, EN50082-1: 1992 USA Features UL AMCX: Central Station Alarm Units (UL1610, UL1635), AOTX:
90 | Accessories for Control Panels and Keypads | Interface Modules Output (Indicating Appliance Circuit Bell Output) Current Supplied: 2 up to 1.75 A Reference Numbers DOC number: 1249 5895 A FCC Registration number: ESVUSA-20294-KX-N Load Number: 2 REN: 0.1B Ordering Information DS7420i Dual Phoneline/Bell Supervision Module Provides two supervised 12 VDC signaling outputs, one Class A (Style D) input zone, and dual telephone line transmission. Bosch Security Systems B.V. DS7420i www.
Accessories for Control Panels and Keypads | Door Access Control Modules | 91 Door Access Control Module (DACM) 2 Features ▶ Supports up to 500 users without PC software and up to 2,000 users with PC software ▶ Operates as an integrated security system component or as a stand-alone door controller ▶ Works with a variety of reader types and credential formats ▶ Users can administer the DACM from the reader keypad, security system keypad, or PC software In a system with a DACM and an integrated control pa
92 | Accessories for Control Panels and Keypads | Door Access Control Modules 2 Installation/Configuration Notes Technical Specifications Compatibility Information DACM • • Control Panels Credential Formats Reader Types DS7240V2 and DS7220V2 Control Panels DS7400Xi V4+ Control Panel firmware revision 4.10 or greater Compatibility is subject to encryption type, encoding, and format type. • Proximity ISO 50 bit • Wiegand 8 to 50 bit • Magstripe AXM • Proximity • 125 KHz • 13.
Accessories for Control Panels and Keypads | Door Access Control Modules | 93 Ordering Information IUI‑READKP/DACM Proximity Reader with Keypad Graphite gray case with integrated keypad. IUI-READKP/DACM IUI‑READER/DACM Proximity Reader Graphite gray case. IUI-READER/DACM IUI‑CARD/DACM Proximity Cards Each package contains ten cards. IUI-CARD/DACM IUI‑FOB/DACM Proximity Key Fobs Each package contains ten key fobs.
94 | Accessories for Control Panels and Keypads | Door Access Control Modules 2 IUI‑FOB/DACM Proximity Key Fobs IUI‑CABLE/DACM Cable Ordering Information IUI‑CABLE/DACM Cable Provides PC serial communication. IUI-CABLE/DACM Ordering Information IUI‑FOB/DACM Proximity Key Fobs Each package contains ten key fobs. Bosch Security Systems B.V. IUI-FOB/DACM www.boschsecurity.
Accessories for Control Panels and Keypads | Door Access Control Modules | 95 IUI‑CNTRL/DACM Controller IUI‑DTU/DACM Data Transfer Unit (DTU) Ordering Information Ordering Information IUI‑CNTRL/DACM Controller For use with all DACM kits. www.boschsecurity.com IUI-CNTRL/DACM IUI‑DTU/DACM Data Transfer Unit (DTU) Transfers programming information from the computer to the controller without a direct computer connection. IUI-DTU/DACM Bosch Security Systems B.V.
96 | Accessories for Control Panels and Keypads | Door Access Control Modules 2 IUI‑READER/DACM Proximity Reader IUI‑READKP/DACM Proximity Reader with Keypad Ordering Information IUI‑READER/DACM Proximity Reader Graphite gray case. IUI-READER/DACM Ordering Information IUI‑READKP/DACM Proximity Reader with Keypad Graphite gray case with integrated keypad. Bosch Security Systems B.V. IUI-READKP/DACM www.boschsecurity.
Accessories for Control Panels and Keypads | Door Access Control Modules | 97 IUI‑SWCD/DACM PC Software 2 The DACM PC software allows you to add or delete DACM users, set PIN length for stand‑alone DACMs, and set door‑open time. Use the software to store over 60 database fields per user, including photograph, company details, department, personnel data, and vehicle details. Search, door‑open alarm, and door contact settings functions are available.
98 | Accessories for Control Panels and Keypads | Enclosures 2 AE1 Standard Enclosure (Gray) AE3 Large Enclosure (Gray) The AE1 is a gray enclosure that accommodates an optional tamper switch for monitoring the door. It is made of 1.0 mm cold‑rolled steel and includes a keyed lock. The dimensions are 35.6 cm x 31.8 cm x 7.6 cm (14 in. x 12.5 in. x 3 in.). The AE3 is a large gray enclosure that accommodates an optional tamper switch for monitoring the door. It is made of 1.
Accessories for Control Panels and Keypads | Enclosures | 99 AE20 Universal Plastic Enclosure D203 Enclosure 2 Certifications and Approvals The AE20 Enclosure's flexible design accommodates a number of input, output and receiver modules whose circuit boards have either through‑hole or three‑point mounting systems. The enclosure can be mounted to a single gang/double gang box, a 9 cm (3.5 in.) octagonal box, or a 10 cm (4 in.) square box. It may also be surface mounted.
100 | Accessories for Control Panels and Keypads | Power Supplies and Batteries Battery 12 V / 10 Ah 2 Certifications and Approvals VdS-Approval number: G 189 231, G 189 170, G 193 064 Region Certification Germany VdS G 104057, C Batterie 12 Ah Parts Included Qty. Components 1 12 V / 10 Ah battery, with connection accessories Technical Specifications 12 V / 10 Ah dry batteries Rated voltage 12 V DC Rated capacity (K20) 10 Ah Recommended charge voltage 13.
Accessories for Control Panels and Keypads | Power Supplies and Batteries | 101 Battery 12 V / 17 Ah 2 Certifications and Approvals Region Certification Germany VdS G 104058, C Batterie 18 Ah Parts Included Qty. Components 2 12V / 17Ah battery, with connection accessories Technical Specifications 12V / 17Ah dry batteries Rated voltage 12V DC Rated capacity (K20) 17Ah Recommended charge voltage 13.8V DC at 20°C Recommended charge current 0.1 to 0.2A Weight 9.
102 | Accessories for Control Panels and Keypads | Power Supplies and Batteries Battery 12 V / 24 Ah 2 Certifications and Approvals VdS-Approval number: G 196 025, G 182 026, G 196 022, G 102 004 Region Certification Germany VdS G 104059, C Batterie 26 Ah Parts Included Qty. Components 2 12 V / 24 Ah battery Technical Specifications 12V / 24 Ah dry batteries Rated voltage 13,8 V DC Rated capacity (K20) 24 Ah Recommended charge current 0.1 to 0.2 A Weight 9.
Accessories for Control Panels and Keypads | Power Supplies and Batteries | 103 Battery 12 V / 65 Ah 2 Certifications and Approvals Region Certification Germany VdS G 104048, C Batterie 65 Ah Parts Included Qty. Components 1 Battery 12 V / 65 Ah Technical Specifications 12 V / 65 Ah dry battery Rated capacity 65 Ah Rated voltage 13.8 V DC_ Recommended charge current 0.1 to 0.
104 | Accessories for Control Panels and Keypads | Power Supplies and Batteries 2 D1222 Battery (12 V, 2.2 Ah) Technical Specifications Nominal Voltage: 12 VDC Rated Capacity: 2.2 Ah (20 hr) Internal Resistance: 50 mΩ (20°C full charge) Compatible Control Panels VR8 Desktop Alarm System Dimensions: 178 mm x 34 mm x 60 mm (7 in. x 1.3 in. x 2.3 in.) ▶ Fully rechargeable Weight: 1.0 kg (2.
Accessories for Control Panels and Keypads | Power Supplies and Batteries | 105 D1250 Battery (12 V, 5 Ah) Technical Specifications Physical Specifications Nominal Voltage: 12 V Nominal Capacity (20 Hour) 5 Ah Weight: 1.85 kg (4 lb) Dimensions: 10 cm x 9 cm x 7 cm (4 in. x 3.5 in. x 2.8 in.) Height with Terminals: 10.6 cm (4.2 in.) Standard Terminal: FI-Faston Tab No. 187 2 Capacity 20 Hour rate (0.25 A): 5 Ah 10 hour rate (0.45 A): 4.
106 | Accessories for Control Panels and Keypads | Power Supplies and Batteries 2 D126 Standby Battery (12 V, 7 Ah) Certifications and Approvals Region Certification USA UL ALVY: Access Control Systems Units (UL294), APOU: Proprietary Alarm Units (UL1076), UEHX7: Signaling Appliances, Miscellaneous Certified for Canada (cUL) FM CSFM 7167-1615: 100, 7165-1615: 112, 7165-1615: 113, 7165-1615: 119, 7167-1615: 124, 7170-1615: 144, and 7170-1615: 145 July 2008 NYC/BSA 582-85-SA DSI CDFM Installatio
Accessories for Control Panels and Keypads | Power Supplies and Batteries | 107 ICP‑EZPS Wire‑in Power Supply ICP‑EZPS‑FRA AFNOR Power Supply Technical Specifications Primary Voltage Input (AC): 110 V +10/-15% (60 Hz) 230 V +10/-15% (50 Hz) Ordering Information ICP‑EZPS‑FRA AFNOR Power Supply For use in France. Provides 14 VDC and isolated auxiliary power outputs. ICP-EZPS-FRA For use in Europe, the Middle East, Asia Pacific, Central and South America. 100 VAC to 240 VAC primary voltage input (AC).
108 | Accessories for Control Panels and Keypads | Power Supplies and Batteries NEV 300 LSN power supply 2 Features ▶ Can be connected to all LSN control panels (centralized or decentralized) ▶ A maximum of two 12 V/17 Ah batteries can be used ▶ Monitoring of mains and battery voltage ▶ Tamper protection (tamper contact) ▶ 3 freely programmable open collector outputs ▶ Slot for optional voltage converter (to 28 V) The NEV 300 LSN is an additional power supply for LSN control panels.
Accessories for Control Panels and Keypads | Power Supplies and Batteries | 109 • The LSN a/b line current, max. 100 mA, is supplied by the control panel. The NEV 300 LSN can be operated directly next to the control panel (centralized) or remotely (decentralized). Installation cable for LSN technology: J-Y(St)Y Shielding (drain wire) must be routed to the ground connectors for each LSN line. There must be no connection between the housing potential and the LSN cable shielding.
110 | Accessories for Control Panels and Keypads | Cables, Switches, and Programmers 2 ICP‑EZPK Programming Key CC808 Direct Link Cable Ordering Information Transfers program information to and from the control panel. Use the programming key to quickly program a group of Easy Series Intrusion Control Panels with the same characteristics. The programming key is color-coded blue.
Accessories for Control Panels and Keypads | Control Center and Keypad Accessories | 111 IUI‑EZT‑5 Easy Series Token Package 2 Five Easy Series proximity tokens. Ordering Information IUI‑EZT‑5 Easy Series Token Package Five Easy Series proximity tokens. www.boschsecurity.com IUI-EZT-5 Bosch Security Systems B.V.
Bosch Security Systems B.V. www.boschsecurity.
Software 3 Programming Software www.boschsecurity.com 114 Bosch Security Systems B.V.
114 | Software | Programming Software Remote Programming Software International Report Capability All report types are fully functional. Users can select a range of pages and either print them or save them as an HTML, .pdf, .rtf, .xls, or .txt file. Context-sensitive and Quick Help Selectable, context-sensitive Help files correspond to the program record sheet items for each control panel.
Software | Programming Software | 115 Technical Specifications Mechanical Compatible Modems Refer to the online Help file included in the RPS installation for a list of compatible modems. Generally, modems must originate a call in Answer Mode but must not use data compression, flow control, or error correction (LAPM, MNP). Answer Tones: Must transmit 2025 Hz or 2270 Hz answer tones Protocol: Must be capable of BELL System 103 or V.
116 | Software | Programming Software WDSRP Remote Programming Software for Windows 3 Anti-takeover Lockout Some control panels feature an anti-takeover lockout that will deny unauthorized people the ability to reprogram the control panel from the keypad. This feature can be set to lock out phone number changes only, thus preventing account takeover, while allowing local service of other features, or it can be set to lock out all keypad programming.
Software | Programming Software | 117 Reduced Liability The supported control panels maintain all local functionality while remote programming sessions are in progress. No indication of remote program access is visible from the keypad. The control panel can still be armed, disarmed, bypassed with all alarm sounders operational. Your liability is limited since remote programming sessions will not result in lengthy periods of panel in-operation that could result in delayed response to emergencies.
Bosch Security Systems B.V. www.boschsecurity.
4 Arming Devices www.boschsecurity.com Conventional 120 LSN 124 Bosch Security Systems B.V.
120 | Arming Devices | Conventional SE 50 GLT SmartKey Blocking Unit 4 Functions The SE 50 GLT control unit controls the blocking element depending on the state of the bolt contact and/or the intrusion control panel. When the door is closed (bolt contact is activated), the bolt of the blocking element is automatically engaged. When the door is unlocked, the bolt is disengaged if the detection area is disarmed.
Arming Devices | Conventional | 121 Operating voltage 10.8 V to 30.0 V Total current consumption including blocking element • • • • Bolt disengaged 38 mA Bolt engaged 53 mA When being engaged 140 mA for 300 ms When blocking 200 mA for 200 ms Environmental conditions • • • Protection category IP 30 Operating temperature -5 °C to +45 °C Storage temperature -40 °C to +85 °C 4 Housing • • Material ABS Color RAL 9002 Dimensions (H x W x D) 160 x 135 x 35 mm Weight 0.
122 | Arming Devices | Conventional SE 100 GLT SmartKey Arming Device Functions The individual components of the system can be put together as required for the intended usage. The SE 100 GLT can be operated with or without the blocking element. SE 100 GLT The SE 100 conventional (GLT) control unit processes the status reports of all components in the system, communicates these reports to the intrusion alarm system and controls the blocking element. The control unit is mounted in the secure area.
Arming Devices | Conventional | 123 • The input unit should primarily be installed flushmounted. Parts Included Ordering Information SE 100 GLT SmartKey Arming Device For arming/disarming an intrusion alarm system via the reader as a system solution IUI-SKCU1C-100 Accessories Type Qty.
124 | Arming Devices | LSN SE 60 LSNi SmartKey Blocking Unit the detection area is activated, the bolt remains engaged, thus preventing unintended access to the area. If no bolt contact is realized, the bolt of the SPE blocking element is engaged by the activation signal issued by the control panel. SE 60 LSNi The SE 60 LSNi control unit processes the status reports of all components in the system, communicates these reports to the intrusion alarm system and controls the SPE blocking element.
Arming Devices | LSN | 125 Ordering Information Parts Included Type Qty. Component SE 60 LSNi 1 SmartKey blocking unit, control unit SE 60 LSNi SmartKey Blocking Unit For mechanically locking doors IUI-SKCUOL-60 Technical Specifications SE 60 LSNi control unit Operating voltage 4 9.6 V to 30 V Total current consumption including blocking element at an input voltage of 9.6 V • • • • Standby LSN part 3.
126 | Arming Devices | LSN SE 120 LSNi SmartKey Arming Device System Overview 4 1 SPE blocking element 2 SE 120 LSNi control unit 3 Bolt contact Features 4 Reader ▶ Simple, non-contact operation 5 SmartKey keys ▶ High security through “Challenge & Response” procedure 6 LSN control panel ▶ Clear signaling prevents operational errors ▶ No manipulation or tampering possible Functions ▶ Detailed logging of arming via the LSN control panel Individual system components can be put together de
Arming Devices | LSN | 127 Standard key (without security card) The keys are not numbered and can be read in as often as required. The keys are labeled with an 8-digit identification number. SPE blocking element The SPE blocking element is an additional lock for the door and is intended to prevent unauthorized entry to the armed area. The SPE blocking element must always be mounted in the secure area with a kit to allow it to be fitted out for different door types.
128 | Arming Devices | LSN SE 220 LSNi SmartKey Arming Device System Overview 4 Features 1 SPE blocking element 2 SE 220 LSNi control unit 3 Bolt contact 4 SmartKey keys ▶ SmartKey code keypad can be used as a "coded arming device" with integrated reader 5 Code keypad with integrated reader ▶ Code keypads can be used as a "coded arming device" in conjunction with the reader 6 Reader 7 Code keypad 8 LSN control panel ▶ Simple, non-contact operation ▶ High security through “Challenge &
Arming Devices | LSN | 129 If someone is forced to disarm the intrusion alarm system, a silent alarm (hold-up alarm) can be set off remotely via the code keypad. The code keypad can be surface mounted or flush mounted (outside the secure area). A standard magnetic contact can be connected to the control unit (not part of the scope of delivery). Reader Certifications and Approvals Arming and disarming is carried out using an electronic key on the reader.
130 | Arming Devices | LSN SE 220 LSNi control unit Total current consumption including blocking element at an input voltage of 28 V • • • • Standby LSN part 3.
Arming Devices | LSN | 131 SE 320 LSNi SmartKey Arming Device System Overview 4 1 SPE blocking element Features 2 SE 320 LSNi control unit ▶ SmartKey code keypad can be used as a "coded arming device" with integrated reader 3 Bolt contact ▶ Code keypads can be used as a "coded arming device" in conjunction with the reader 4 SmartKey keys 5 Code keypad with integrated reader 6 Code keypad (as autonomous code keypad) 7 Reader 8 Code keypad 9 LSN control panel 10 Door opener relay or
132 | Arming Devices | LSN Arming/disarming is carried out by using the SmartKey key then entering the user code. If someone is forced to disarm the intrusion alarm system, a silent alarm (hold-up alarm) can be set off remotely via the code keypad. The code keypad can be surface mounted or flush mounted (outside the secure area). Reader 4 Arming and disarming is carried out using an electronic key on the reader. LED and buzzer provide information about the status of the system as well as operation.
Arming Devices | LSN | 133 Installation/Configuration Notes Operating voltage Number of SmartKey keys Total current consumption including blocking element at an input voltage of 9.6 V A maximum of 16 SmartKey keys can be used per system if the SmartKey key is read in at the reader. In other respects, the number of SmartKey keys depends on the control panel: NZ 300 LSN = 40 keys, UEZ = 255 keys.
Bosch Security Systems B.V. www.boschsecurity.
5 Detectors and Accessories www.boschsecurity.com Motion PIR 136 Motion PIR/Microwave 164 Motion Outdoor 183 Motion Ceiling Mount 186 Motion Long Range 202 Request-to-Exit 211 Glass Break 216 Seismic 220 Photoelectric Beam 223 Holdup 230 Smoke 231 Magnetic Contacts Recessed Mount 240 Magnetic Contacts Surface Mount 266 Accessories 286 Bosch Security Systems B.V.
136 | Detectors and Accessories | Motion PIR ISC‑PPR1‑W16 Professional Series PIR Detector Functions Sensor Data Fusion Technology Sensor data fusion technology is a unique feature that uses a sophisticated software algorithm to gather signals from multiple sensors: two pyroelectric sensors, a room temperature sensor, and a white light level sensor. The microcontroller analyzes and compares the sensor data to make the most intelligent alarm decisions in the security industry.
Detectors and Accessories | Motion PIR | 137 Solid State Relays Region Certification Solid state relays send silent alarm output signals to provide a higher level of security and reliability. An external magnet does not activate the relay. The solid state relay uses less current than a mechanical relay, providing longer standby capacity during a power loss.
138 | Detectors and Accessories | Motion PIR Technical Specifications Electrical Power Requirements Voltage (Operating): 9 VDC to 15 VDC Current (Maximum): < 15 mA Current (Standby): < 10 mA at 12 VDC Relay: Solid state relay, normally-closed (NC) contacts, power supervised. 3 W, 125 mA, 25 VDC, resistance < 10 Ω Tamper: Normally-closed (NC) contacts (with cover on) rated at 25 VDC, 125 mA maximum. Connect tamper circuit to 24-hour protection circuit.
Detectors and Accessories | Motion PIR | 139 ISC‑PPR1‑WA16x Professional Series PIR Detectors with Anti‑mask Functions Sensor Data Fusion Technology Sensor data fusion technology is a unique feature that uses a sophisticated software algorithm to gather signals from multiple sensors: two pyroelectric sensors, a microwave assist sensor, a room temperature sensor, and a white light level sensor.
140 | Detectors and Accessories | Motion PIR Self-adjusting LED The LED brightness adjusts automatically to the surrounding light level. A blue light-emitting diode (LED) indicates an alarm condition and activates during a walk test.
Detectors and Accessories | Motion PIR | 141 Technical Specifications Electrical Power Requirements Voltage (Operating): 9 VDC to 15 VDC Current (Maximum): < 26 mA with alarm, trouble, and LEDs active. Current (Standby): 18 mA at 12 VDC Relay: Solid state relay, normally-closed (NC) contacts, power supervised. 3 W, 125 mA, 25 VDC, resistance < 10 Ω. Tamper: Normally-closed (NC) contacts (with cover on) rated at 25 VDC, 125 mA maximum. Connect tamper circuit to 24-hour protection circuit.
142 | Detectors and Accessories | Motion PIR ISM‑BLP1 Blue Line PIR Detector Draft and Insect Immunity The sealed optical chamber prevents drafts and insects from affecting the detector. Temperature Compensation The detector adjusts its sensitivity so that it can identify human intruders at critical temperatures. Certifications and Approvals 5 Region Certification Europe CE 89/336/EEC, EN55022: 1998 +A1: 2000 +A2: 2003 (ANSI C63.
Detectors and Accessories | Motion PIR | 143 Installation/Configuration Notes Parts Included Coverage Patterns Quant.
144 | Detectors and Accessories | Motion PIR Ordering Information B328 Gimbal‑mount Bracket Mounts on a single-gang box and allows rotation of a detector. Wires are hidden inside. B328 Swiveling B335-3 low-profile mount Swiveling, low-profile, plastic mount for wall mounting. The vertical swivel range is +10° to -20°, while the horizontal swivel range is ±25°. Available in triple packs. B335-3 5 Bosch Security Systems B.V. www.boschsecurity.
Detectors and Accessories | Motion PIR | 145 ISM‑BLP1‑P Blue Line Pet‑Friendly PIR Detector Draft and Insect Immunity The sealed optical chamber prevents drafts and insects from affecting the detector. Temperature Compensation The detector adjusts its sensitivity to maintain its ability to identify human intruders at critical temperatures. Certifications and Approvals Region Certification Europe CE 89/336/EEC, EN55022: 1998 +A1: 2000 +A2: 2003 (ANSI C63.
146 | Detectors and Accessories | Motion PIR Installation/Configuration Notes Parts Included Coverage Patterns Quant.
Detectors and Accessories | Motion PIR | 147 Ordering Information ISM‑BLA1‑SM Blue Line Sounder Module Fits all Blue Line detectors ISM-BLA1-SM B328 Gimbal‑mount Bracket Mounts on a single-gang box and allows rotation of a detector. Wires are hidden inside. B328 Swiveling B335-3 low-profile mount Swiveling, low-profile, plastic mount for wall mounting. The vertical swivel range is +10° to -20°, while the horizontal swivel range is ±25°. Available in triple packs. B335-3 5 www.boschsecurity.
148 | Detectors and Accessories | Motion PIR ISM‑BLQ1 Blue Line Quad PIR Detector Functions First Step Processing (FSP) First Step Processing (FSP) almost instantly responds to human targets without producing false alarms from other sources. FSP adjusts the detector's sensitivity based on signal amplitude, polarity, slope, and timing. This eliminates the need for the installer to select the sensitivity level.
Detectors and Accessories | Motion PIR | 149 Australia C-tick Ukraine IEC 60839‑1‑3‑2001, IEC 60839‑2‑2‑2001, IEC 60839‑2‑6‑2001, GOST 26342‑84, GOST 27990‑88 Europe Complies with EN50131-2-2 Grade 2 Installation/Configuration Notes Input power must be provided by an approved limited power source. All outputs must be connected to SELV (safety extra-low voltage) circuits only. Standby Power This detector has no internal standby battery.
150 | Detectors and Accessories | Motion PIR Ordering Information ISM‑BLQ1 Blue Line Quad PIR Detector Uses two individual sensors that operate like two PIRs in one ISM-BLQ1 Accessories 5 ISM‑BLA1‑CC Blue Line Color Camera Module (NTSC format) NTSC format ISM-BLA1-CC-N ISM‑BLA1‑CC Blue Line Color Camera Module (PAL format) PAL format ISM-BLA1-CC-P ISM‑BLA1‑LM Blue Line Nightlight Module Fits all Blue Line detectors ISM-BLA1-LM ISM‑BLA1‑SM Blue Line Sounder Module Fits all Blue Line detectors ISM
Detectors and Accessories | Motion PIR | 151 DS306E PIR Detector France AFNOR NF, A2P Installation/Configuration Notes Mounting Considerations The DS306E PIR Detector tolerates temperature changes resulting from heaters, air conditioners, and drafts. It also tolerates light fluctuations resulting from sunlight, lightning, and moving headlights.
152 | Detectors and Accessories | Motion PIR Ordering Information Side View Optional Barrier Coverage: (OMB77) 25 m x 5 m (80 ft x 16 ft) 5 Top View Optional Long Range Coverage: (OMLR77) 40 m x 3 m (120 ft x 10 ft) Side View Optional Long Range Coverage: (OMLR77) 40 m x 3 m (120 ft x 10 ft) DS306E Wall Mount PIR Detector DS306E Wall Mount PIR Detector DS306E DS306E Wall Mount PIR Detector for France DS306E Wall Mount PIR Detector; for use in France DS306E-FRA Accessories B328 Gimbal‑mount Bracket
Detectors and Accessories | Motion PIR | 153 DS308EA Quad PIR Detector with Anti-mask Q-map Signal Processing Analyzes the signals from each channel to eliminate false alarms. The horizontally opposed signals must match with specific timing, amplitude, and signatures to cause an alarm. Q-map adjusts for small targets that cause signals in one channel but not the adjacent, opposing channel.
154 | Detectors and Accessories | Motion PIR Installation/Configuration Notes Top View Optional Long Range Coverage: (OMLR77) 40 m x 3 m (120 ft x 10 ft) 5 Side View Optional Long Range Coverage: (OMLR77) 40 m x 3 m (120 ft x 10 ft) Technical Specifications Enclosure Design Top View Standard Broad Coverage 15 m x 15 m (50 ft x 50 ft) Dimensions: 14.6 cm x 9.5 cm x 6.35 cm (5.75 in. X 3.75 in. X 2.
Detectors and Accessories | Motion PIR | 155 Ordering Information DS308EA Quad PIR Intrusion Detector Provides 15 m x 15 m (50 ft x 50 ft) coverage, anti-masking with spray detect, quad element design, microprocessor controlled self-test supervision systems and Q-map signal processing. DS308EA DS308EA‑FRA Quad PIR Intrusion Detector For use in France.
156 | Detectors and Accessories | Motion PIR MX775i Multiplex PIR Intrusion Detector • • • Standard: Recommended setting for maximum false alarm immunity. Tolerates environment extremes on this setting. Not recommended for Long Range or Barrier type patterns. The detector is shipped in Standard Sensitivity mode. Intermediate: Recommended setting for any location where an intruder is expected to cover only a small portion of the protected area. Tolerates normal environments on this setting.
Detectors and Accessories | Motion PIR | 157 Top View Optional Long Range Coverage: 25 m to 36 m x 3 m (80 ft to 120 ft x 10 ft) Side View Optional Long Range Coverage: 25 m to 36 m x 3 m (80 ft to 120 ft x 10 ft) Top View Standard Broad Coverage: 9 m to 15 m x 15 m (30 ft to 50 ft x 50 ft) Technical Specifications Environmental Considerations Temperature (Operating): -29°C to +49°C (-20°F to +120°F). For UL Listed Requirements, the temperature range is 0°C to +49°C (+32°F to +120°F).
158 | Detectors and Accessories | Motion PIR Ordering Information OMLR77‑3 Long‑range Mirror Provides long-range coverage with a 40 m x 3 m (120 ft x 10 ft) pattern. Shipped in packages of three. OMLR77-3 5 Bosch Security Systems B.V. www.boschsecurity.
Detectors and Accessories | Motion PIR | 159 MX934i Multiplex PIR Intrusion Detector • Intermediate Sensitivity: Recommended setting for any location where an intruder is expected to cover only a small portion of the protected area. Tolerates normal environments on this setting. This setting identifies intruders more accurately. High Sensitivity: Fast response to intruder signals. For use in quiet environments where heat and light fluctuations are not anticipated.
160 | Detectors and Accessories | Motion PIR Side View Optional Long Range Coverage: 21 m x 3 m (70 ft x 10 ft) Technical Specifications Enclosure Design Dimensions: 5 10.8 cm x 7 cm x 4.6 cm (4.25 in. x 2.75 in. x 1.8 in.
Detectors and Accessories | Motion PIR | 161 Ordering Information MX934i Multiplex PIR Intrusion Detector Provides Motion Analyzer II processing, unique address switch settings, insect and draft immunity, and three sensitivity settings. MX934i Accessories Swiveling B335-3 low-profile mount Swiveling, low-profile, plastic mount for wall mounting. The vertical swivel range is +10° to -20°, while the horizontal swivel range is ±25°. Available in triple packs.
162 | Detectors and Accessories | Motion PIR DS304 PIR Detector with Replaceable Mirrors Test Features The DS304 Detector has an external alarm LED (light emitting diode). Walk test remote control means that you can enter a command at the control panel to activate the walk test LED. Alarm Memory Provides indication of stored alarms. Controlled by a switched voltage from the control panel.
Detectors and Accessories | Motion PIR | 163 Environmental Considerations Operating Temperature: -10°C to +55°C Relative Humidity: <95%, non-condensing Storage Temperature: -20°C to +60°C Radio Frequency Interference (RFI) Immunity: No alarm or setup on critical frequencies in the range from 10 MHz to 1 GHz at 30 V/m. Complies with Environmental Class II (EN50130-5) Mounting Height Range: 2 m to 2.
164 | Detectors and Accessories | Motion PIR/Microwave ISC‑PDL1‑W18x Professional Series TriTech Detectors Functions Sensor Data Fusion Technology Sensor data fusion technology is a unique feature that uses a sophisticated software algorithm to gather signals from five sensors: two pyroelectric sensors, range adaptive radar, a room temperature sensor, and a white light level sensor.
Detectors and Accessories | Motion PIR/Microwave | 165 Self-adjusting LED The LED brightness adjusts automatically to the surrounding light level. A blue light-emitting diode (LED) indicates dual alarms and activates during a walk test. A yellow LED indicates microwave alarms, and a red LED indicates PIR alarms.
166 | Detectors and Accessories | Motion PIR/Microwave Installation/Configuration Notes Use an optional B328 Gimbal-mount Bracket or B335-3 Low-profile Swivel-mount Bracket to surface-mount the detector on a flat wall or in a corner. Use an optional B338 Universal Ceiling Bracket to mount the detector on the ceiling. Wiring Considerations Recommended wire size is 0.2 mm2 to 1 mm2 (26 AWG to 16 AWG).
Detectors and Accessories | Motion PIR/Microwave | 167 Environmental Relative Humidity: 0 to 95%, non-condensing Temperature (Operating and Storage): -29°C to +55°C (-20°F to +130°F) For UL Certificated installations, 0°C to +49°C (+32°F to +120°F) Environmental Class II EN 50130-5 Protection Rating: IP41, IK04 (EN 60529, EN 50102) Ordering Information ISC‑PDL1‑W18G Professional Series TriTech+ Detector 10.525 GHz frequency. ISC-PDL1-W18G ISC‑PDL1‑W18H Professional Series TriTech+ Detector 10.
168 | Detectors and Accessories | Motion PIR/Microwave ISC‑PDL1‑WA18x Professional Series TriTech+ Detectors with Anti‑mask Functions Sensor Data Fusion Technology Sensor data fusion technology is a unique feature that uses a sophisticated software algorithm to gather signals from five sensors: two pyroelectric sensors, a range adaptive radar sensor, a room temperature sensor, and a white light level sensor.
Detectors and Accessories | Motion PIR/Microwave | 169 Self-adjusting LEDs The LED brightness adjusts automatically to the surrounding light level. A blue light-emitting diode (LED) indicates TriTech+ alarms and activates during a walk test. A yellow LED indicates microwave alarms, and a red LED indicates PIR alarms.
170 | Detectors and Accessories | Motion PIR/Microwave Technical Specifications Electrical Power Requirements Voltage (Operating): 9 VDC to 15 VDC Current (Maximum): < 26 mA with alarm, trouble, and LEDs active. Current (Standby): 18 mA at 12 VDC Outputs for All Models 5 Tamper: Normally-closed (NC) contacts (with cover on) rated at 25 VDC, 125 mA maximum. Connect tamper circuit to 24-hour protection circuit. Trouble: Solid state relay normally-closed (NC) contacts.
Detectors and Accessories | Motion PIR/Microwave | 171 Ordering Information ISC‑PDL1‑WA18G TriTech+ Detector with Anti-mask 10.525 GHz frequency. ISC-PDL1-WA18G ISC‑PDL1‑WA18GB TriTech+ Detector with Anti-mask 10.525 GHz frequency. Includes solid state relay, normally-open (NO) alarm contacts. ISC-PDL1-WA18GB ISC‑PDL1‑WA18H TriTech+ Detector with Anti-mask 10.588 GHz frequency. For use in France and the United Kingdom.
172 | Detectors and Accessories | Motion PIR/Microwave ISM‑BLD1 Blue Line TriTech Detectors 5 Functions Advanced Signal Processing Adaptive processing adjusts to background disturbances, reducing false alarms without sacrificing intruder detection. First Step Processing (FSP) almost instantly responds to human targets without producing false alarms from other sources. FSP adjusts the detector's sensitivity based on signal amplitude, polarity, slope, and timing.
Detectors and Accessories | Motion PIR/Microwave | 173 Technical Specifications Environmental Considerations Complies with EN50131-2-4 Environmental Class II, Security Grade 2 Relative Humidity: 0 to 85%, non-condensing Temperature (operating): -29°C to +49°C (-20°F to +120°F) Mechanical Properties Color: White Dimensions: 13.2 cm x 6.1 cm x 4.8 cm (5.2 in. x 2.4 in. x 1.9 in.
174 | Detectors and Accessories | Motion PIR/Microwave ISM‑BLD1‑P Blue Line Pet Friendly TriTech Detectors Functions Advanced Signal Processing Adaptive processing adjusts to background disturbances, reducing false alarms without sacrificing the ability to respond to an intruder. First Step Processing (FSP) almost instantly responds to human targets without producing false alarms from other sources. FSP adjusts the detector's sensitivity based on signal amplitude, polarity, slope, and timing.
Detectors and Accessories | Motion PIR/Microwave | 175 Region Certification Russia GOST Top View Broad: 11 m x 11 m (35 ft x 35 ft) ISM-BLD1-P-F1: IEC 60839-1-3-2001, IEC 60839-2-2-2001, IEC 60839-2-6-2001, GOST 26342-84, GOST 27990-88 1 Microwave coverage area 2 PIR coverage pattern ISM-BLD1-P-F1: GOST 12997-84, GOST R 50009-2000, GOST R 51317.3.2-99, GOST R 51317.3.
176 | Detectors and Accessories | Motion PIR/Microwave Outputs Digital Alarm: 5 V normally, ground for 4 sec during alarm. Relay: Solid state, supervised Form A normally-closed (NC) contacts rated for 125 mA, 28 VDC, 3 W. Tamper: Normally-closed (NC) contacts (with cover on) rated at 28 VDC, 125 mA maximum. Connect tamper circuit to 24-hour protection circuit.
Detectors and Accessories | Motion PIR/Microwave | 177 DS825 and DS840 Series TriTech PIR Detectors Microwave Signal Processing Pattern recognition circuitry identifies and ignores repetitive false alarm sources. Adaptive processing adjusts to background disturbances. This helps to reduce false alarms while maintaining catch performance.
178 | Detectors and Accessories | Motion PIR/Microwave Installation/Configuration Notes Side View DS840 Broad Coverage 12 m x 12 m (40 ft x 40 ft) Technical Specifications 5 Enclosure Design Dimensions: 10.8 cm x 7 cm x 4.6 cm (4.25 in. X 2.75 in. X 1.8 in.) Material: High impact ABS plastic enclosure Environmental Considerations Top View DS825 Broad Coverage 7.5 m x 7.
Detectors and Accessories | Motion PIR/Microwave | 179 Ordering Information DS825 Detector (10.525 GHz) Operates at 10.525 GHz. Provides 7.5 m x 7.5 m (25 ft x 25 ft) coverage, first step processing, movable mirrors, pet and animal immunity. DS825 DS825T Detector (10.525 GHz) Operates at 10.525 GHz. Includes a tamper switch. Provides 7.5 m x 7.5 m (25 ft x 25 ft) coverage, first step processing, movable mirrors, pet and animal immunity. DS825T DS825TA Detector (10.687 GHz) Operates at 10.687 GHz.
180 | Detectors and Accessories | Motion PIR/Microwave DS860 Series TriTech PIR/ Microwave Detector Adjustable PIR and Microwave Sensitivity • PIR Signal Processing: Motion Analyzer II uses multiple thresholds and timing windows to analyze timing, amplitude, duration and polarity of signals to make an alarm decision. Will not alarm on extreme levels of thermal and illumination disturbances caused by heaters and air conditioners, hot and cold drafts, sunlight, lightning, and moving headlights.
Detectors and Accessories | Motion PIR/Microwave | 181 Region Certification Brazil ANATEL DS860 only: 0667-03-1855 Singapore iDA DS860 only: LPREQ-S0150-2004 Europe DS860‑A complies with EN50131‑1 Grade 2 Technical Specifications Installation/Configuration Notes Enclosure Design Dimensions: 12.7 cm x 7.1 cm x 5.6 cm (5 in. X 2.8 in. X 2.2 in.) Material: High impact ABS plastic enclosure.
182 | Detectors and Accessories | Motion PIR/Microwave Ordering Information Accessories 5 B328 Gimbal‑mount Bracket Mounts on a single-gang box and allows rotation of a detector. Wires are hidden inside. B328 Swiveling B335-3 low-profile mount Swiveling, low-profile, plastic mount for wall mounting. The vertical swivel range is +10° to -20°, while the horizontal swivel range is ±25°. Available in triple packs. B335-3 B800 Ceiling‑mount Bracket Surface mounts detectors to the ceiling.
Detectors and Accessories | Motion Outdoor | 183 OD850 Series Outdoor TriTech Detectors The detectors can distinguish between small, repetitive motions such as tree limbs moving in the wind and the more purposeful motions of intruders. These advanced processing techniques and the detectors' mechanical design combine to provide superior performance in a wide range of weather conditions.
184 | Detectors and Accessories | Motion Outdoor Certifications and Approvals 5 Region Certification Europe CE 89/336/EEC, EN55022: 1998 +A1:2000 +A2:2003, EN50130-4: 1996 +A1:1998 +A2:2003, EN61000-3-3: 1995 +A1:2001, EN61000-4-2: 1995 +A1:1998 +A2:2001, EN61000-4-3: 2002 +A1:2002, EN61000-4-4: 1995 +A1:2000 +A2:2001, EN61000-4-5: 1995 +A1:2001, EN61000-4-6: 1996 +A1:2001, EN61000-4-11" 1994 +A1:2001, EN300 440-1 V1.3.1: 2001-09, EN300 440-2 V1.1.
Detectors and Accessories | Motion Outdoor | 185 Ordering Information OD850‑F1 Outdoor TriTech Detector (10.525 GHz) For use in Belgium, Czech Republic, Denmark, Greece, Hungary, Italy, Netherlands, Norway, Poland, Romania, Spain, Sweden, Ukraine, the Americas and the Asia/Pacific Region. Operates at 10.525 GHz. For use outdoors or in harsh environments. Provides Motion Analyzer II PIR signal processing, two sensitivity levels, draft and insect immunity, and 15 m x 15 m (50 ft x 50 ft) coverage.
186 | Detectors and Accessories | Motion Ceiling Mount DS936 Low Profile Panoramic PIR Detector 5 Certifications and Approvals Region Certification Europe CE DS936: 89/336/EEC, EN55022: 1998 +A1: 2000 +A2: 2003, EN50130-4: 1996 +A1: 1998 +A2: 2003, EN61000-4-2: 1995 +A1: 1998 +A2: 2001, EN61000-4-3: 2002 +A1: 2003, EN61000-4-4: 1995 +A1: 2000 +A2: 2001, EN61000-4-5: 1995 +A1: 2001, EN61000-4-6: 1996 +A1: 2001 +A2: 2001, EN61000-4-11:1994 +A1: 2001, EN60950-1: 2001 +A11: 2004 USA UL DS936: ANSR: In
Detectors and Accessories | Motion Ceiling Mount | 187 Technical Specifications Enclosure Design Material: High impact ABS plastic enclosure Dimensions: 3.05 cm x 11.7 cm (1.2 in. x 4.6 in.) Environmental Considerations Operating Temperature: -29°C to +49°C (-20°F to +120°F) For UL Certificated installations, 0°C to +49°C (+32°F to +120°F) Radio Frequency Interference (RFI) Immunity: No alarm or setup on critical frequencies in the range from 26 MHz to 950 MHz at 50 V/m.
188 | Detectors and Accessories | Motion Ceiling Mount DS937 Panoramic Detector Certifications and Approvals Region Certification Europe CE EN 50081-1: 1992 (EN 55022: 1998, Class B), EN 50130-4: 1995 +A1: 1998, IEC 61000-4-2: 1995, IEC 61000-4-3: 1995, IEC 61000-4-4: 1995, IEC 61000-4-5: 1995, ENV 50141: 1993 USA UL ANSR: Intrusion Detection Units (UL639) Installation/Configuration Notes 5 Features ▶ Low profile design ▶ 360° up to 14 m (50 ft) coverage ▶ Easy installation ▶ First to alarm and
Detectors and Accessories | Motion Ceiling Mount | 189 Enclosure Design Dimensions: 12.7 cm x 3.8 cm (5 in. x 1.5 in.) Weight: 176 g (6.2 oz) Environmental Considerations Humidity: 0 to 95% humidity non-condensing Operating Temperature: -10°C to +49°C (+14°F to +120°F) For UL Listed Applications, 0°C to +49°C (+32°F to +120°F) Mounting Height Range: 2.4 m to 3.
190 | Detectors and Accessories | Motion Ceiling Mount DS938Z and ZX938Z Series Panoramic PIR Detectors Motion Monitor Switch-selectable four or thirty day Motion Monitor supervision timers provide the detector with the ability to verify that there is a clear view of the protection area and that it has not been blocked. Test Features Three externally visible high output alarm LEDs visible from any angle, flash to indicate trouble condition.
Detectors and Accessories | Motion Ceiling Mount | 191 Installation/Configuration Notes Mounting Height (recommended): 2.5 m to 6 m (8 ft to 18 ft) Location: Mounts directly to ceiling or to standard octagonal electrical box. Internal Pointability: Coverage is adjustable ±10° horizontally, +2° to -18° vertically. Outputs (DS models) Alarm: Form C reed relay at 3.0 W, 125 mA at 28 VDC for resistive loads Tamper: Normally-closed. Contacts rated at 28 VDC, 125 mA maximum.
192 | Detectors and Accessories | Motion Ceiling Mount DS939 Panoramic Detector Test Features • High efficiency LED and light-pipe system provide walk test indication that is easily viewable from any angle and at any mounting height. • Alarm memory feature allows detector to latch the alarm LED to aid in response. • Remote LED walk-test control allows the LED to be enabled or disabled using a switched input without accessing the detector.
Detectors and Accessories | Motion Ceiling Mount | 193 Ordering Information DS939 Panoramic Detector Provides a 21 m (70 ft) panoramic coverage pattern and can be used on ceilings as high as 7.6 m (25 ft). DS939 Side View Coverage Information Coverage is 360° x 21 m (70 ft) diameter when the detector is mounted 3.7 to 7.6 m (12 ft to 25 ft). 5 Coverage is 15 m (50 ft) diameter when the detector is mounted at 3 m (10 ft). Coverage is 12 m (40 ft) when the detector is mounted at 2.4 m (8 ft).
194 | Detectors and Accessories | Motion Ceiling Mount DS9360 Panoramic TriTech Detector Microwave Signal Processing Adaptive processing adjusts to background disturbances. This helps to reduce false alarms while maintaining catch performance. Test Features Two high output tri-color alarm LEDs visible from any angle, and flash to indicate a trouble condition.
Detectors and Accessories | Motion Ceiling Mount | 195 AR13-18 Side View One of each type of mirror is shipped with the product. 360° x 18 m (60 ft) diameter Technical Specifications 5 Enclosure Design Design: Modular high impact ABS electronic head and mounting/wiring base design with rugged polyethylene dome provides easy access to field setup switches. Dimensions: 8.5 cm x 13.3 cm (3.5 in. x 5.25 in.
196 | Detectors and Accessories | Motion Ceiling Mount DS9370 Series Panoramic TriTech Detector First Step Processing FSP allows virtually instant response to human targets without sacrificing false alarm immunity to other sources. By adjusting its sensitivity based upon signal amplitude, polarity, slope and timing, FSP eliminates the need for the installer to select the sensitivity level for the application.
Detectors and Accessories | Motion Ceiling Mount | 197 Installation/Configuration Notes Environmental Considerations Operating Temperature: -40°C to +49°C (-40°F to +120°F) For UL Certificated installations, 0°C to +49°C (+32°F to +120°F) Radio Frequency Interference (RFI) Immunity: No alarm or setup on critical frequencies in the range from 26 MHz to 950 MHz at 50 V/m. DS9370-C: Complies with Environmental Class II (EN50130-5) Microwave Frequency DS9370 and DS9370-BEL 10.525 GHz DS9370-C 10.
198 | Detectors and Accessories | Motion Ceiling Mount DS9371 Panoramic TriTech Detector First Step Processing (FSP) allows virtually instant response to human targets without generating false alarms for other sources. FSP adjusts the detector's sensitivity based on signal amplitude, polarity, slope, and timing. This eliminates the need for the installer to select the sensitivity level.
Detectors and Accessories | Motion Ceiling Mount | 199 Installation/Configuration Notes A masking kit containing two 120° and two 90° masks is included to allow masking unwanted areas. Apply the masks to the outside of the detector. With the supplied masks, you can mask 90°, 120°, 180°, 210°, 240°, or 330°. Power Considerations • Power Limits: Input power must be provided by an Approved Limited Power Source. All outputs must be connected to safety extra-low voltage (SELV) circuits only.
200 | Detectors and Accessories | Motion Ceiling Mount MX938i Multiplex Intrusion Detector Selectable Sensitivity • Standard: Recommended setting for maximum false alarm immunity. Tolerates environment extremes on this setting. Not recommended for Long Range or Barrier type patterns. The detector is shipped in Standard Sensitivity mode. • Intermediate: Recommended setting for any location where an intruder is expected to cover only a small portion of the protected area.
Detectors and Accessories | Motion Ceiling Mount | 201 Installation/Configuration Notes Technical Specifications Environmental Considerations Temperature (Operating): -29°C to +49°C (-20°F to +120°F). For UL Listed Requirements, the temperature range is 0°C to +49°C (+32°F to +120°F). Power Requirements Standby Power: There is no internal standby battery. Connect to DC power sources capable of supplying standby power if primary power fails. For each hour of standby time needed, 350 µAh are required.
202 | Detectors and Accessories | Motion Long Range DS720i Long Range TriTech PIR Detector (10.525 GHz) PIR Signal Processing Uses Motion Analyzer II multiple thresholds and timing windows to analyze timing, amplitude, duration, and polarity of signals to make an alarm decision. Will not alarm on extreme levels of thermal and illumination disturbances caused by heaters and air conditioners, hot and cold drafts, sunlight, lightning, and moving headlights. Two sensitivity settings are provided.
Detectors and Accessories | Motion Long Range | 203 Installation/Configuration Notes Standard Broad Coverage 27 m x 21 m (90 ft x 70 ft); the standard broad coverage mirror (OA90) is included. Side View Parts Included Quantity Component 1 B334 Swivel Mount Bracket 1 Standard Broad Coverage Mirror, labeled OA90 1 Long Range Coverage Mirror, labeled OA300 Note The Long Range Coverage Mirror is installed. Technical Specifications Enclosure Design Top View Dimensions: 20.8 cm x 19.
204 | Detectors and Accessories | Motion Long Range Ordering Information DS720i Long Range TriTech PIR Detector (10.525 GHz) Operates at 10.525 GHz. Provides 27 m x 21 m (90 ft x 70 ft) standard broad coverage and 91 m x 4.6 m (300 ft x 15 ft) long range coverage. Provides anti-masking with spray detect, motion monitor, and Motion Analyzer II signal processing. DS720i Accessories 5 OA120‑2 Mirror A 36.5 m (120 ft) optical array module. Shipped in packages of two. Bosch Security Systems B.V.
Detectors and Accessories | Motion Long Range | 205 DS778 Long Range PIR Detector Insect and Draft Immunity The sealed optical chamber provides immunity to drafts and insects.
206 | Detectors and Accessories | Motion Long Range Outputs Alarm: Form C contacts rated at 3.0 W, 125 mA at 28 VDC for resistive loads. Tamper: Normally-closed. Contacts rated at 28 VDC, 125 mA maximum. Power Requirements 5 Current Draw: 18 mA at 12 VDC Voltage: 6 VDC to 15 VDC Ordering Information DS778 Long Range PIR Detector Provides Motion Analyzer II processing, movable mirrors, Q-map signal processing, long range coverage, and four mounting options.
Detectors and Accessories | Motion Long Range | 207 DS794Z and ZX794Z Series Long Range PIR Detectors Motion Monitor Switch-selectable four and thirty day timers verify that there is a clear view of the protection area. PIR Supervision Provides trouble output in the event that PIR circuitry fails.
208 | Detectors and Accessories | Motion Long Range Environmental Considerations Operating Temperature: Top View Standard Long Range: 61 m x 3 m (200 ft x 10 ft) -29°C to +49°C (-20°F to +120°F) For UL Certificated installations, 0°C to +49°C (+32°F to +120°F) Radio Frequency No alarm or setup on critical frequencies in the range Interference from 26 MHz to 950 MHz at 50 V/m.
Detectors and Accessories | Motion Long Range | 209 MX794i Long Range Multiplex PIR Detector • • Intermediate: The recommended setting for OA200 coverage or for locations where an intruder is expected to cover only a small portion of the protected area. Tolerates normal environments on this setting. High: The setting for fast response to intruder signals. For use in quiet environments where thermal and illumination transients are not anticipated.
210 | Detectors and Accessories | Motion Long Range Power Requirements Current Draw (2-wire): Top View A200 Mirror Module: 61 m x 3 m (200 ft x 10 ft) 5 Side View A200 Mirror Module: 61 m x 3 m (200 ft x 10 ft) LED Off: < 350 µA draw on mux bus In Alarm; LED On: 2 mA draw on mux bus Current Draw (4-wire): LED Off: < 350 µA draw on mux bus, 0 mA draw on Aux. power In Alarm; LED On: < 350 µA draw on mux bus, 3 mA draw on Aux. power Standby Power: There is no internal standby battery.
Detectors and Accessories | Request-to-Exit | 211 DS150i Series Request-toexit Detectors Certifications and Approvals Region Certification Europe CE 89/336/EEC, EN55022: 1998 +A1: 2000 +A2: 2003, EN50130-4: 1996 +A1: 1998 +A2: 2003, EN61000-4-2: 1995 +A1: 1998 +A2: 2001, EN61000-4-3: 2002 +A1: 2003, EN61000-4-4: 1995 +A1: 2000 +A2: 2001, EN61000-4-5: 1995 +A1: 2001, EN61000-4-6: 1996 +A1: 2001 +A2: 2001, EN61000-4-11:1994 +A1: 2001, EN60950-1: 2001 USA UL ALVY: Access Control Systems Units (UL294)
212 | Detectors and Accessories | Request-to-Exit Ordering Information DS150i Request‑to‑exit PIR Detector Gray enclosure. For use in request-to-exit (REX) applications. Provides 2.4 m x 3 m (8 ft x 10 ft) coverage. DS150i DS151i Request‑to‑exit PIR Detector Black enclosure. For use in request-to-exit (REX) applications. Provides 2.4 m x 3 m (8 ft x 10 ft) coverage. DS151i Accessories 5 Side View A side view of the DS150i and DS151i coverage pattern.
Detectors and Accessories | Request-to-Exit | 213 DS160 Series High Performance Request‑to‑exit Detectors Door Monitor The sensor can monitor a door contact to allow special control of the internal relay. For example, if the door is opened within the relay time period, the sensor can be programmed to halt the timer. If the door is not opened within a specific time period, the relay can be programmed to deactivate.
214 | Detectors and Accessories | Request-to-Exit Coverage Information The coverage (detection area) varies depending on the mounting height above the floor, angle of the lens, and whether the unit is mounted on a wall above the door or on the ceiling. The coverage is 2.4 m x 3 m (8 ft x 10 ft) The coverage patterns for the detector at a height of 2.3 m (7.5 ft) are shown. The coverage pattern increases or decreases with height and detector alignment.
Detectors and Accessories | Request-to-Exit | 215 Ordering Information DS160 Request‑to‑exit Detector Light gray enclosure. For use in request-to-exit (REX) applications. Provides 2.4 m x 3 m (8 ft x 10 ft) coverage, timers, door monitor with sounder alert, and pointable coverage. DS160 DS161 Request‑to‑exit Detector Black enclosure. For use in request-to-exit (REX) applications. Provides 2.4 m x 3 m (8 ft x 10 ft) coverage, timers, door monitor with sounder alert, and pointable coverage.
216 | Detectors and Accessories | Glass Break DS1100i Series Glassbreak Detectors is powered and functioning by clapping his hands. Externally visible alarm LED indicates an alarm or test condition and can be programmed to latch if desired.
Detectors and Accessories | Glass Break | 217 Technical Specifications Mechanical Tamper Output: Normally-closed cover activated tamper switch with separate terminals. Contacts rated at 28 VDC, 125 mA maximum. Environmental Operating Temperature: -29°C to +49°C (-20°F to +120°F) For UL Certificated installations, 0°C to +49°C (+32°F to +120°F) Radio Frequency Interference (RFI) Immunity: No alarm or setup on critical frequencies in the range from 26 MHz to 950 MHz at 50 V/m.
218 | Detectors and Accessories | Glass Break DS1109i Glassbreak Detector 5 Certifications and Approvals Region Certification Europe CE 89/336/EEC, EN55022: 1998 +A1: 2000 +A2: 2003, EN50130-4: 1996 +A1: 1998 +A2: 2003, EN61000-4-2: 1995 +A1: 1998 +A2: 2001, EN61000-4-3: 2002 +A1: 2003, EN61000-4-4: 1995 +A1: 2000 +A2: 2001, EN61000-4-5: 1995 +A1: 2001, EN61000-4-6: 1996 +A1: 2001 +A2: 2001, EN61000-4-11: 1994 +A1: 2001, EN60950-1: 2001 +A11: 2004 USA UL ANSR: Intrusion Detection Units (UL639) In
Detectors and Accessories | Glass Break | 219 Ordering Information DS1109i Glassbreak Detector Mounts to door or window frames. Includes an internal magnetic contact. DS1109i Accessories DS1110i Glassbreak Tester Used to test DS1101i, DS1102i, DS1103i, and DS1108i Glass Break Detectors. Powered by a 9 V alkaline battery (supplied). DS1110i 5 www.boschsecurity.com Bosch Security Systems B.V.
220 | Detectors and Accessories | Seismic ISN-SM Seismic Detectors Functions Detection The seismic detector recognizes vibrations caused by explosives and tools such as diamond-tipped drills, mechanical and hydraulic rams, flame cutters, thermal lances, or water jet cutters. The SENSTEC sensor and the digital signal processing monitor a narrow frequency range, thus offering reliable detection. The seismic detector tolerates environmental conditions such as air movement and noise.
Detectors and Accessories | Seismic | 221 Certifications and Approvals Function test For the test: Low < 1.5 VDC High > 3.
222 | Detectors and Accessories | Seismic Ordering Information 5 ISN-GMX-P0 mounting plate Mounting plate for seismic detectors. Weight: 0.27 kg. Suitable for mounting seismic detectors to steel or concrete surfaces. Screw or weld the mounting plate directly onto the surface. ISN-GMX-P0 ISN-GMX-P3S swivel plate For use with ISN-SM-50 seismic detectors. Monitors safes and strong rooms with exposed keyholes. ISN-GMX-P3S ISN-GMX-PZ swivel plate For use with ISN-SM-80 seismic detectors.
Detectors and Accessories | Photoelectric Beam | 223 DS415i and DS435i Single Beam Photoelectric Detectors Test Features • Alarm LED • Margin test switch to assist with alignment Certifications and Approvals Region Certification Poland CNBOP DS435i USA UL DS415i and DS435i: ANSR: Intrusion Detection Units (UL639) Canada ULC DS415i-CAN: ANSRC: Intrusion Detection Units Technical Specifications Photobeam DS415i Range: 150 m (500 ft) DS435i Range: 150 m (500 ft) Enclosure Design Features ▶ 1
224 | Detectors and Accessories | Photoelectric Beam Ordering Information DS415i Detector Provides AC/DC operation and battery backup. Includes a P333 Standby Battery. The range is 150 m (500 ft). DS415i DS435i High Performance Detector Provides DC operation only, alarm memory, and inhibit wiring. The range is 150 m (500 ft). DS435i 5 Bosch Security Systems B.V. www.boschsecurity.
Detectors and Accessories | Photoelectric Beam | 225 DS422i and DS426i Dual‑Beam Photoelectric Detectors Installation/Configuration Notes Mounting Considerations Can be surface or pole mounted. Technical Specifications Photobeam DS422i Range Indoor: 90 m (300 ft), Outdoor: 30 m (100 ft) DS426i Range Indoor: 180 m (600 ft), Outdoor: 60 m (200 ft) Response Time: Selectable from 50 ms to 700 ms 5 Enclosure Design Dimensions: 17.1 cm x 8.2 cm x 8.7 cm (6.75 in. x 3.25 in. x 3.5 in.
226 | Detectors and Accessories | Photoelectric Beam DS453Q and DS455Q Quad Beam Photoelectric Detectors Certifications and Approvals Region Certification Europe CE 89/336/EEC, EN50130-4: 1996 +A1: 1998 +A2: 2003, EN61000-6-3: 2001 +A11: 2004 USA UL ANSR: Intrusion Detection Units (UL639) China CCC 2003031901000085 Installation/Configuration Notes 5 Mounting Considerations Mount these detectors on surfaces or poles. Pole mount to 4.1 cm to 4.5 cm (1.625 in. to 1.75 in) O. D. pole.
Detectors and Accessories | Photoelectric Beam | 227 Ordering Information DS453Q Photoelectric Detector Provides an outdoor range of 110 m (360 ft). DS453Q DS455Q Photoelectric Detector Provides an outdoor range of 160 m (525 ft). DS455Q Accessories PC1A Weather Enclosure Protects detectors when mounted outside. The enclosure’s dimensions are 39.4 cm x 10.3 cm x 6 cm (15.5 in. x 4 in. x 2.4 in.). Shipped in packages of two.
228 | Detectors and Accessories | Photoelectric Beam DS484Q and DS486Q Quad‑Beam Photoelectric Detectors Multiple Channel Operation Configure the detectors for up to eight different channels. This allows multiple units to be used near one another without the possibility of receiver cross-talk. This is particularly useful when stacking multiple beam sets.
Detectors and Accessories | Photoelectric Beam | 229 Environmental Considerations Operating Tempera- -25° C to + 55° C (-13°F to + 130° F) ture: IP Rating: IP 54 (protection against dust; protection against splashing water) Mounting Considerations Location: Surface or pole mount Pattern Pointability: ±90° horizontal, ±10° vertical Power Requirements Voltage: 10.
230 | Detectors and Accessories | Holdup ND 100 GLT Panic Button Environmental class 2 Housing • • • Housing material ABS Housing color RAL 9002 Cover color Gray Weight Approx. 0.
Detectors and Accessories | Smoke | 231 F220 Photoelectric Smoke Detectors • • • • • • F220-B6R Standard 12/24 VDC Four‑wire Mounting Base F220-B6RS 24 VDC Four‑wire Mounting Base with Sounder F220-B6C 12/24 VDC Four‑wire Mounting Base with Auxiliary Relay F220-B6E 12/24 VDC Four‑wire Power Supervision Mounting Base F220-B6PM 24 VDC Four‑wire Addressable Master Base F220-B6PS 12/24 VDC Four‑wire Addressable Base Monitoring the Detection Chamber These detectors have several features that work together to
232 | Detectors and Accessories | Smoke Dual-color LED A dual-color LED indicator flashes green every 8 sec when the detector has power and the smoke sampling circuitry is working. If CleanMe is enabled, the green LED double flashes (two flashes a half second apart) every 8 sec to indicate normal operation. The LED turns red if an alarm is sent. After the alarm condition clears, reset the detector by interrupting its power.
Detectors and Accessories | Smoke | 233 F220-B6PM: with D299: 18.9 VDC to 28.0 VDC without D299: 9.6 VDC to 28.0 VDC F220- B6PS: 18.9 VDC to 28.0 VDC Trademarks Chamber Check® is a registered trademark of Bosch Security Systems in the United States. Chambermaid™ is a trademark of Bosch Security Systems in the United States. CleanMe® is a registered trademark of GE Interlogix in the United States and/ or other countries.
234 | Detectors and Accessories | Smoke F220 Heat Detectors • • • • • • F220‑B6R Standard 12/24 VDC Four-wire Mounting Base F220‑B6RS 24 VDC Four-wire Mounting Base with Sounder F220‑B6C 12/24 VDC Four-wire Mounting Base with Auxiliary Form C Relay F220‑B6E 12/24 VDC Four-wire Power Supervision Mounting Base F220‑B6PM 24 VDC Four-wire Addressable Master Base F220‑B6PS 12/24 VDC Four-wire Addressable Base Dual-color LED To verify the detector has power and the heat detection circuitry functions, a dual-c
Detectors and Accessories | Smoke | 235 Two-wire: Bosch Security Systems, Inc. makes no claim written, oral, or implied that the F220 Heat Detectors work with any two-wire control panels except those specified in the Control Panel Compatibility chart in the Technical Service Note (P/N: 4998148185). Four-wire: compatible with all UL Listed four-wire control panels. Refer to the control panel's installation instructions for proper end-of-line (EOL) resistor selection.
236 | Detectors and Accessories | Smoke F220‑B6 Series Conventional Detector Bases Installation/Configuration Notes Compatibility Information Two‑wire: Bosch Security Systems, Inc. makes no claim written, oral, or implied that the F220‑B6 Series Detector Bases work with any two‑wire control panels except those specified in the Two-wire Detector/Control Panel Compatibility List Technical Service Note (P/N: 4998148185). Four‑wire: Compatible with all UL Listed four‑wire control panels.
Detectors and Accessories | Smoke | 237 Technical Specifications Environmental Considerations Relative Humidity: Up to 95%, non‑condensing Temperature (operating): +32°F to +100°F (0°C to +38°C) Mechanical Properties Color: Off-white Dimensions (diameter x D) 6 in. x 0.9 in. (15.2 cm x 2.3 cm) Material: Fire‑resistant plastic 5 Ordering Information F220‑B6 12/24 VDC Two‑wire Base Standard base for two‑wire (12 VDC or 24 VDC system) applications.
238 | Detectors and Accessories | Smoke F220‑B6RS 24 VDC Four‑wire Detector Base with Sounder 5 2. Reverse Polarity Configuration: In this configuration (not suitable for synchronized protocols; such as, Cooper Wheelock, Gentex, or System Sensor), the sounders in a loop activate due to reversed polarity on the power line. The output pattern is not controlled by the base in this operating mode; it follows the reversing power signal on the detector head's terminals as programmed at the control panel. 3.
Detectors and Accessories | Smoke | 239 • F220‑PTHC1 Photoelectric Smoke Detector with +135°F (+57°C) Heat Sensor and Carbon Monoxide Sensor Enhancement1 • F220‑135 Electronic Rate‑of‑Rise, Fixed Temperature +135°F (+57°C) Heat Detector • F220‑135F Electronic Fixed Temperature +135°F (+57°C) Heat Detector • F220‑190F Electronic Fixed Temperature +190°F (+88°C) Heat Detector 1 The F220‑PTHC detects carbon monoxide (CO) as a component of a fire.
240 | Detectors and Accessories | Magnetic Contacts Recessed Mount ISN‑CSTB‑10 Compact Contacts (9.5 mm) 5 Technical Specifications Specifications for all Models Gap Width: 12.7 mm (0.5 in.) Contact Dimensions: 9.5 mm x 19 mm (0.375 in. x 0.75 in.) Wire Lead Type: 0.8 mm (0.029 in.) 22 AWG, 7 stranded Wire Lead Length: 46 cm (18 in.
Detectors and Accessories | Magnetic Contacts Recessed Mount | 241 ISN‑CSTB‑10DM Contacts with Thin Magnet (9.5 mm) Parts Included Quantity Per Package Component 10 Contacts 10 Magnets Technical Specifications Specifications for All Models Features Gap Width: 12.7 mm (0.5 in.) Contact Dimensions: 9.5 mm x 19 mm (0.375 in. x 0.75 in.) Magnet Dimensions: 3.2 mm x 9.5 mm (0.125 in. x 0.375 in.) Wire Lead Type: 0.8 mm (0.029 in.) 22 AWG, 7 stranded Wire Lead Length: 46 cm (18 in.
242 | Detectors and Accessories | Magnetic Contacts Recessed Mount ISN‑CSTB‑TC Terminal Connection Contacts (16 mm) Installation/Configuration Notes Compatibility Information All contact models are compatible with control panel models that accept contact inputs. Parts Included Quantity Per Package Component 10 Contacts 10 Magnets 5 Technical Specifications Specifications for All Models Gap Width: 16 mm (0.625 in.) Contact Dimensions: 9.5 mm x 25 mm (0.375 in. x 1 in.
Detectors and Accessories | Magnetic Contacts Recessed Mount | 243 Ordering Information Brown Terminal Connection Contact Brown recessed contact with 9.5 mm (0.375 in.) diameter. Includes standard magnet. Package contains ten contacts and ten magnets. ISN-CSTB-TCB White Terminal Connection Contact White recessed contact with 9.5 mm (0.375 in.) diameter. Includes standard magnet. Package contains ten contacts and ten magnets.
244 | Detectors and Accessories | Magnetic Contacts Recessed Mount ISN‑CTC75 Terminal Connection Contacts (19 mm) Parts Included Quantity Per Package Component 10 Contacts 10 Magnets Technical Specifications Specifications for All Models 5 Features ▶ Closed loop ▶ Terminal connection design Gap Width: 25 mm (1 in.) Contact Dimensions: 19 mm x 30 mm (0.75 in. x 1.18 in.
Detectors and Accessories | Magnetic Contacts Recessed Mount | 245 ISN‑CTAP‑10 Contacts (9.5 mm) Features Technical Specifications Specifications for All Models Gap Width: 19 mm (0.75 in.) Contact Dimensions: 9.5 mm x 31.75 mm (0.375 in. x 1.25 in.) Wire Lead Type: 0.8 mm (0.029 in.) 22 AWG, 7 stranded Wire Lead Length: 46 cm (18 in.
246 | Detectors and Accessories | Magnetic Contacts Recessed Mount Ordering Information White Flange Contact with Standard Magnet White recessed contact with 9.5 mm (0.375 in.) diameter and flange design. Includes a standard magnet. Package contains ten contacts and ten magnets. ISN-CTAP-FMW 5 Bosch Security Systems B.V. www.boschsecurity.
Detectors and Accessories | Magnetic Contacts Recessed Mount | 247 ISN‑CTAP‑15 Contacts (6.35 mm) Features Technical Specifications Specifications for All Models Gap Width: 19 mm (0.75 in.) Contact Dimensions: 6.35 mm x 25 mm (0.25 in. x 1 in.) Wire Lead Type: 0.8 mm (0.029 in.) 22 AWG, 7 stranded Wire Lead Length: 46 cm (18 in.
248 | Detectors and Accessories | Magnetic Contacts Recessed Mount ISN‑CRFM‑25 Oval Flange Contacts (6.35 mm) 5 Technical Specifications Specifications for All Models Gap Width: 19 mm (0.75 in.) Contact Dimensions: 6.35 mm x 25 mm (0.25 in. x 1 in.) Oval Flange Dimension: 9.5 mm (0.375 in.) Wire Lead Type: 0.8 mm (0.029 in.) 22 AWG, 7 stranded Wire Lead Length: 46 cm (18 in.
Detectors and Accessories | Magnetic Contacts Recessed Mount | 249 ISN‑CMINI‑10 Miniature Contacts (9.5 mm) Technical Specifications Specifications for All Models Gap Width: 12.7 mm to 25 mm (0.5 in. to 1 in.) Contact Dimensions: 9.5 mm x 43 mm (0.375 in. x 1.7 in.) Wire Lead Type: 0.8 mm (0.029 in.) 22 AWG, 7 stranded Wire Lead Length: 46 cm (18 in.
250 | Detectors and Accessories | Magnetic Contacts Recessed Mount ISN‑CMINI‑10D Miniature Contacts with Thin Magnet (9.5 mm) Parts Included Quantity Per Package Component 10 Contacts 10 Magnets Technical Specifications Specifications for All Models 5 Features ▶ Closed loop ▶ Ideal for tight-fitting applications ▶ Versatile Gap Width: 12.7 mm (0.5 in.) Contact Dimensions: 9.5 mm x 15.2 mm (0.375 in. x 0.6 in.) Magnet Dimensions: 9.5 mm x 3 mm (0.375 in. x 0.125 in.) Wire Lead Type: 0.
Detectors and Accessories | Magnetic Contacts Recessed Mount | 251 ISN‑CMINI‑15 Miniature Contacts (6.35 mm) Technical Specifications Specifications for All Models Gap Width: 12.7 mm (0.5 in.) Contact Dimensions: 6.35 mm x 15.2 mm (0.25 in. x 0.6 in.) Wire Lead Type: 0.8 mm (0.029 in.) 22 AWG, 7 stranded, or 26 AWG Wire Lead Length: 46 cm (18 in.
252 | Detectors and Accessories | Magnetic Contacts Recessed Mount ISN‑C22 Compact Ball Reed Contacts 5 Features ▶ Closed loop ▶ Includes spacer and screws ▶ Shorter length for tight-fitting areas Technical Specifications Specifications for All Models Gap Width: 6.7 mm (0.25 in.) Contact Dimensions: 19 mm x 25 mm x 25 mm (0.75 in. x 1 in. x 1 in.) Flange Width: 4.5 cm (1.75 in.) Flange Thickness: 1.5 mm (0.06 in.
Detectors and Accessories | Magnetic Contacts Recessed Mount | 253 ISN‑CPB52 Reed Plunger Contacts Parts Included Quantity Per Package Component 10 Assemblies (contacts, spacers, and screws) Technical Specifications Specifications for All Models Gap Width: Features ▶ Closed loop ▶ Ideal for replacing old mechanical contacts ▶ Ideal for doorjambs ▶ Includes spacers and screws The contacts are available in brown or white. Use on doorjambs or to replace older contacts.
254 | Detectors and Accessories | Magnetic Contacts Recessed Mount Ordering Information 5 Brown Reed Plunger Contact Brown recessed contact with wire lead connection design and 46 cm (18 in.) leads. Package contains ten assemblies with contacts, spacers, and screws. ISN-CPB52-B White Reed Plunger Contact White recessed contact with wire lead connection design and 46 cm (18 in.) leads. Package contains ten assemblies with contacts, spacers, and screws.
Detectors and Accessories | Magnetic Contacts Recessed Mount | 255 ISN‑CAS Adjustable Screw Head Contacts Features ▶ Closed loop ▶ Tamper switch ▶ Adjustable gap width Technical Specifications Specifications for All Models Gap Width: 1.6 mm to 2.6 mm (0.06 in. x 0.10 in.) Push in the reed plunger up to 1.6 mm (0.06 in.) without activating contacts. Push in the reed plunger to 2.6 mm and the contacts must activate. Contact Dimensions without Screws: 9.5 mm x 31 mm (0.375 in. x 1.25 in.
256 | Detectors and Accessories | Magnetic Contacts Recessed Mount ISN‑CRB32 Roller Ball Contacts Parts Included Quantity Per Package Component 10 Assemblies (contacts, spacers, screws, and reed switches) Technical Specifications Specifications for All Models 5 Features ▶ Closed loop Contact Dimensions without Screws: 19 mm x 41.27 mm (0.75 in. x 1.625 in.) Wire Lead Type: 0.8 mm (0.029 in.) 22 AWG, 7 stranded Wire Lead Length: 46 cm (18 in.
Detectors and Accessories | Magnetic Contacts Recessed Mount | 257 ISN‑CSD70 and ISN‑CSD80 Compact Contacts Parts Included Quantity Per Package Component 10 Contacts 10 Magnets Technical Specifications Specifications for All Models Gap Width: 38 mm (1.5 in.) Wire Lead Type: 0.8 mm (0.029 in.) 22 AWG, 7 stranded Wire Lead Length: 46 cm (18 in.) standard leads Switch Configuration Type: Single pole single throw (SPST) Features Operating Temperature Range: 7.2°C to -95.
258 | Detectors and Accessories | Magnetic Contacts Recessed Mount Ordering Information 5 Brown Compact Contact with Standard Ma gnet (19 mm) Brown recessed contact with 19 mm (0.75 in.) diameter. Includes a standard magnet. Package contains ten contacts and ten magnets. ISN-CSD70-B White Compact Contact with Standard Mag net (19 mm) White recessed contact with 19 mm (0.75 in.) diameter. Includes a standard magnet. Package contains ten contacts and ten magnets.
Detectors and Accessories | Magnetic Contacts Recessed Mount | 259 EMK 46 S Z Flush-Mount Magnetic Contact 1 Contact 2 Magnet 3 Installation offset Distances diagram 5 Features ▶ Conventional flush-mount magnetic contact ▶ VdS class C 1 Extraction ▶ Tamper switch 2 Proximity switch part Note: If the attached magnets are touching each other, there will be no tamper zone! ▶ Head-on flush mounting ▶ Conventional perimeter protection Parts Included Conventional magnet contacts are used for tear-
260 | Detectors and Accessories | Magnetic Contacts Recessed Mount Dimensions • • • • Contact 8 x 32 mm (Ø x L) Magnet 6 x 30 mm (Ø x L) Plastic sleeve for magnet 8 x 31 mm (Ø x L) Connection cable 3.2 mm, length 6 m 5 Bosch Security Systems B.V. www.boschsecurity.
Detectors and Accessories | Magnetic Contacts Recessed Mount | 261 EMK 46 Z Built-in magnetic contact 1 Contact 2 Magnet 3 Installation offset Distances diagram 5 Features ▶ Conventional flush-mount magnetic contact ▶ VdS class B 1 Extraction ▶ Head-on or parallel flush mounting 2 Proximity switch part ▶ Conventional perimeter protection ▶ Can be used in the SPE blocking element (installed on frames/doors) according to VdS Class B Parts Included Type Qty.
262 | Detectors and Accessories | Magnetic Contacts Recessed Mount MS-LZ Flush-Mount Magnetic Contact Parts Included Type Quant. Component MS-LZ 1 Recessed mount magnetic contacts incl. 6 m cable Technical Specifications Type of installation Flush, parallel or head-on Contact Normally open contact Permissible contact load ≤ 5 Watt Switching current 10 to 100 mA Switching voltage max.
Detectors and Accessories | Magnetic Contacts Recessed Mount | 263 MS-LZS Flush-Mount Magnetic Contact Parts Included Type Quant. Component MS-LZS 1 Recessed mount magnetic contact incl. 6 m cable Technical Specifications Type of installation Flush, parallel or head-on Contact Normally open contact/toggle switch Permissible contact load ≤ 3 Watt Switching current 10 A to 100 mA Switching voltage max.
264 | Detectors and Accessories | Magnetic Contacts Recessed Mount ADM 2000 Spring-loaded mechanism Technical Specifications Spring-loaded mechanism Material Plastic, ABS Pressure force (1/2/3 springs) 2.85 / 5.70 / 8.55 kp Dimensions (H x W x D) 8 x 70 x 36 mm Stroke of the pressure lock: Max. 13.
Detectors and Accessories | Magnetic Contacts Recessed Mount | 265 ADB Spring-loaded bolts for wooden windows Installation/Configuration Notes Installation notes • When installing the magnetic contact used for tear-off surveillance, it should be mounted as far as possible from the hinge. • The distance (L) from the reed contact to the hinge must be measured. • The travel (S) of the reed contact is to be determined with an ohmmeter before installation.
266 | Detectors and Accessories | Magnetic Contacts Surface Mount ISN‑CMICRO Ultra Miniature Contacts Parts Included Quantity Per Package Component 10 Assemblies (contacts and adhesive strips) 10 Magnets Technical Specifications Specifications for All Models Gap Width: 9.5 mm (0.375 in.) Contact Dimensions: 19 mm x 12.7 mm (0.25 in. x 0.5 in.) Wire Lead Type: 0.8 mm (0.029 in.) 22 AWG, 7 stranded Wire Lead Length: 46 cm (18 in.
Detectors and Accessories | Magnetic Contacts Surface Mount | 267 ISN‑C50 Terminal Connection Contacts with Cover Installation/Configuration Notes Compatibility Information All contact models are compatible with control panel models that accept contact inputs. Parts Included Quantity Per Package Component 10 Assemblies (contacts, screws, covers, adhesive strips, and reed switches) 10 Magnets Technical Specifications Specifications for All Models Gap Width: 19 mm (0.75 in.
268 | Detectors and Accessories | Magnetic Contacts Surface Mount ISN‑C60 Slim Terminal Connection Contacts Parts Included Quantity Per Package Component 10 Assemblies (contacts, screws, super adhesive, mounting holes, and tape covers) 10 Magnets Technical Specifications Specifications for All Models 5 Features ▶ Closed loop ▶ Install with screws or with super adhesive Gap Width: 19 mm (0.75 in.) Contact Dimensions: 6.35 mm x 9.5 mm x 50.8 mm (0.25 in. x 0.375 in. x 2 in.
Detectors and Accessories | Magnetic Contacts Surface Mount | 269 ISN‑CSM35 Standard and Wide Gap Contacts Technical Specifications Specifications for All Models Contact Dimensions: 63 mm x 18.6 mm x 13 mm (2.48 in. x 0.73 in x 0.51 in.) Magnetic Assembly Dimensions: 63 mm x 12.2 mm x 13 mm (2.48 x 0.48 in x 0.51 in.
270 | Detectors and Accessories | Magnetic Contacts Surface Mount ISN‑CSM20‑WG Commercial Contacts 5 Features ▶ Closed loop ▶ Ideal for steel doors ▶ Wide gap deters swinging Technical Specifications Specifications for All Models Gap Width: 63.5 mm (2.5 in.) Contact Dimensions: 16 mm x 104.8 mm x 16 mm (0.625 in. x 4.125 in. x 0.625 in.) Wire Lead Type: 0.8 mm (0.029 in.) 22 AWG, 7 stranded Wire Lead Length: 46 cm (18 in.
Detectors and Accessories | Magnetic Contacts Surface Mount | 271 ISN‑CSS‑40 Super Stick Contacts with Side Leads Features ▶ Closed loop ▶ Special super stick adhesive does not fall off, dry off, or freeze off ▶ Side leads Technical Specifications Specifications for All Models Gap Width: 19 mm (0.75 in.) Contact Dimensions: 7.8 mm x 35.56 mm x 7.8 mm (0.31 in. x 1.4 in. x 0.31 in.) Wire Lead Type: 0.8 mm (0.029 in.) 22 AWG, 7 stranded Wire Lead Length: 46 cm (18 in.
272 | Detectors and Accessories | Magnetic Contacts Surface Mount ISN‑C45 Miniature Super Stick Contacts with Side Leads Technical Specifications Specifications for All Models Gap Width: 15.24 mm (0.60 in.) Contact Dimensions: 4.8 mm x 27 mm x 6.35 mm (0.187 in. X 1.06 in. x 0.25 in.) Wire Lead Type: 0.8 mm (0.029 in.) 22 AWG, 7 stranded Wire Lead Length: 46 cm (18 in.
Detectors and Accessories | Magnetic Contacts Surface Mount | 273 ISN‑CFM‑102 Flange Mount Contacts with Side Leads Technical Specifications Specifications for All Models Gap Width: 25 mm (1 in.) Contact Dimensions: 7.62 mm x 33.78 mm x 13.46 mm (0.3 in x 1.33 in. x 0.53 in) Wire Lead Lengths: 46 cm (18 in.) Wire Lead Type: 0.8 mm (0.029 in.
274 | Detectors and Accessories | Magnetic Contacts Surface Mount ISN‑CFM‑106 Flange Mount Contacts with Center Leads Parts Included Quantity Per Package Component 10 Contacts 10 Magnets Technical Specifications Specifications for All Models 5 Features ▶ Closed loop ▶ Flange mount with special adhesive ▶ Center leads ▶ Clean break flange removal Gap Width: 25 mm (1 in.) Contact Dimensions: 7.62 mm x 33.78 mm x 13.46 mm (0.3 in. x 1.33 in. x 0.53 in.) Wire Lead Type: 0.8 mm (0.029 in.
Detectors and Accessories | Magnetic Contacts Surface Mount | 275 ISN‑CMET‑4418 Overhead Door Contact Parts Included Quantity Per Package Component 1 Assembly (contact, epoxy, push-pin, and bracket) 1 Magnet Technical Specifications Gap Width: 50.8 mm (2 in.) Contact Dimensions: 107 mm x 50.8 mm x 12 mm (4 in. x 2 in. x 0.47 in.) Cable Length: 46 cm (18 in.
276 | Detectors and Accessories | Magnetic Contacts Surface Mount ISN‑CMET‑200AR Commercial Metal Contact Technical Specifications Gap Width: 31.75 mm (1.25 in.) Contact Dimensions: 9.5 mm x 16 mm x 50.8 mm (0.375 in. x 0.625 in. x 2 in.) Cable Length: 46 cm (18 in.) Switch Configuration Type: Single pole single throw (SPST) Maximum Contact Resistance: 150 μΩ (micro-ohm) Minimum Breakdown Voltage: 250 VDC 5 Insulation Resistance: 1010 Ω Electrostatic Cap: 0.
Detectors and Accessories | Magnetic Contacts Surface Mount | 277 ISN‑C66 Track Mounted Overhead Door Contact Parts Included Quantity Per Package Component 1 Assembly (contact and bracket) 1 Magnet Technical Specifications Gap Width: 44.45 mm (1.75 in.) Contact Assembly and Bracket Dimensions: 76.2 mm x 66 mm x 45.8 mm (3.07 in x 2.60 in. x 1.80 in.) Cable Length: 46 cm (18 in.
278 | Detectors and Accessories | Magnetic Contacts Surface Mount EMK 46 AT Z SurfaceMount Magnetic Contact Surface mounting • When used on metal frames, the plastic bases must be used. • The supply lines need to be measured electrically before connection. • The contact and the magnet (6 x 30 mm) can only be inserted in the surface mounting housing in conjunction with the plastic sleeve. • Installation on ferromagnetic materials is only permissible with the washer components supplied.
Detectors and Accessories | Magnetic Contacts Surface Mount | 279 Technical Specifications Type of installation Surface mounting/flush mounting, parallel or head-on Permissible operating voltage Max. 40 V_ Contact type 1-pin (normally) open contact Permissible contact load 6 VA Max. 100 V_ Max.
280 | Detectors and Accessories | Magnetic Contacts Surface Mount MK 48 SZ surface-mount magnetic contact 5 Features ▶ Conventional surface-mount magnetic contact ▶ VdS class C 1 Contact 2 Magnet 3 Axial installation offset Distances diagram ▶ Tamper switch ▶ Parallel installation, surface mounted and flush mounted ▶ Conventional perimeter protection ▶ Can be used in the SPE blocking element (installed on frames/doors) according to VdS Class C Conventional magnet contacts are used for tear-off su
Detectors and Accessories | Magnetic Contacts Surface Mount | 281 Technical Specifications Type of installation Surface-mounted/flush-mounted, parallel Permissible operating voltage Max. 40 V Contact type 1-pin (normally) open contact Permissible contact load 6 VA Max. 100 V Max.
282 | Detectors and Accessories | Magnetic Contacts Surface Mount MSA-LZ Surface-Mount Magnetic Contact 5 1 Contact 2 Magnet 3 Offset in the axial direction Parts Included Type Quant. Component MSA-LZ 1 Features Surface-mount magnetic contact incl.
Detectors and Accessories | Magnetic Contacts Surface Mount | 283 MSA-LZS Surface-Mount Magnetic Contact 1 Contact 2 Magnet 3 AG4 surface mounting housing 4 Plastic part 5 Offset in the axial direction 6 Warning! The adjustment mark must point to the magnet. Parts Included Features ▶ Conventional surface-mount magnetic contact Type Quant. Component ▶ VdS class C MSA-LZS 1 ▶ Tamper switch ▶ Parallel or head-on surface mounting Surface-mount magnetic contact with magnet incl.
284 | Detectors and Accessories | Magnetic Contacts Surface Mount AMK 4 Z Overhead door contact • The magnetic switch is installed at ground level (requires a flat surface). Vehicles with rubber tires can drive over the switch without causing problems. In spite of this, the magnetic switch must not be used as a doorstopper. The supply lines need to be measured electrically before connection.
Detectors and Accessories | Magnetic Contacts Surface Mount | 285 AMK 4 S Z Shutter Door Contact • The magnetic switch is installed at ground level (requires a flat surface). Vehicles with rubber tires can drive over the switch without causing problems. In spite of this, the magnetic switch must not be used as a doorstopper. The supply lines need to be measured electrically before connection.
286 | Detectors and Accessories | Accessories ISM‑BLA1‑CC Blue Line Color Camera Modules 5 Certifications and Approvals Region Certification Europe CE -P model only: 89/336/EEC, EN55022: 1998 +A1: 2000 +A2: 2003 (ANSI C63.
Detectors and Accessories | Accessories | 287 Mechanical Properties Side View 1 Camera's viewable area 3 Look-down zone Note Note 2 PIR coverage pattern Color: White Dimensions: 5.6 cm x 6.1 cm x 4.8 cm (2.2 in. x 2.4 in. x 1.9 in.) The passive-infrared (PIR) coverage patterns and look-down zone depend on the specific detector used. Refer to the detector's datasheet.
288 | Detectors and Accessories | Accessories ISM‑BLA1‑LM Blue Line Nightlight Module The brightness level can be set for low or high by positioning a jumper during module installation. Duration The length of time the LEDs remain lit is set with an external switch on the side of the module. Short duration is approximately 20 sec to 30 sec; while long duration is approximately 2 min to 4 min.
Detectors and Accessories | Accessories | 289 Wiring Considerations The three module wires attach to the terminal block of the Blue Line detector. Parts Included Quant.
290 | Detectors and Accessories | Accessories ISM‑BLA1‑SM Blue Line Sounder Module Certifications and Approvals Region Certification Europe CE 89/336/EEC, EN50130-4: 1996 +A1: 1998 +A2: 2003, EN61000-4-2: 1995 +A1: 1998 +A2: 2001, EN61000-4-3: 2002 +A1: 2002, EN61000-4-4: 1995 +A1: 2000 +A2: 2001, EN61000-4-5: 1995 +A1: 2001, EN61000-4-6: 1996 +A1: 2001, EN61000-4-11:1994 +A1: 2001 USA UL NBSX: Household Burglar Alarm System Units (UL1023), NBSX7: Household Burglar Alarm System Units Certified for
Detectors and Accessories | Accessories | 291 Technical Specifications Environmental Considerations Complies with EN50131 Environmental Class II, Security Grade 2 Relative Humidity: Up to 95% non-condensing Up to 85% for UL installations Temperature (operating): -10°C to +49°C (+14°F to +120°F) For UL Listed product installations, 0°C to +49°C (+32°F to +120°F) B328 Gimbal‑mount Bracket Mechanical Properties Color: White Dimensions: 2.5 cm x 6.4 cm x 3.2 cm (1.0 in. x 2.5 in. x 1.25 in.
292 | Detectors and Accessories | Accessories Swiveling B335-3 lowprofile mount B800 Ceiling‑mount Bracket Surface-mount the plastic, low-profile mount to the wall. It is suitable for use with many detector types. The vertical swivel range is +10° to -20°, while the horizontal swivel range is ±25°. Surface mounts detectors to the ceiling. The vertical pivot range is +7° to -16°; the horizontal pivot range is ±45°. Do not use for pet applications.
Detectors and Accessories | Accessories | 293 DS1110i Glassbreak Tester MP1 Metal Pole, 1 m (3 ft) 5 The DS1110i Glassbreak Tester is used to test DS1101i, DS1102i, DS1103i, and DS1108i Glass Break Detectors. It is powered by a 9 V alkaline battery (supplied). Straight metal poles measuring 1 m (3 ft) for pole mounting photoelectric detectors. Shipped in packages of two.
294 | Detectors and Accessories | Accessories MP2 Metal Pole, 1.2 m (4 ft) MP3 L‑Curved Metal Pole 5 Straight metal poles measuring 1.2 m (4 ft) for pole mounting photoelectric detectors. Shipped in packages of two. Curved metal poles for mounting to vertical surfaces for pole mounting photoelectric detectors. Shipped in packages of two. Ordering Information Ordering Information MP2 Metal Pole, 1.2 m (4 ft) Straight metal poles measuring 1.2 m (4 ft) for pole mounting photoelectric detectors.
Detectors and Accessories | Accessories | 295 OLR92‑3 Long‑range Lens OA120‑2 Mirror Provides long-range coverage with a 30.5 m x 3 m (100 ft x 10 ft) pattern. Shipped in packages of three. Ordering Information A 36.5 m (120 ft) optical array module. Shipped in packages of two. OLR92‑3 Long‑range Lens Provides long-range coverage with a 30.5 m x 3 m (100 ft x 10 ft) pattern. Shipped in packages of three. OLR92-3 Ordering Information OA120‑2 Mirror A 36.5 m (120 ft) optical array module.
296 | Detectors and Accessories | Accessories OMB77‑3 Barrier Mirror OMLR77‑3 Long‑range Mirror 5 Provides barrier coverage with a 25 m x 5 m (80 ft x 16 ft) pattern. Shipped in packages of three. Provides long-range coverage with a 40 m x 3 m (120 ft x 10 ft) pattern. Shipped in packages of three. Ordering Information OMB77‑3 Barrier Mirror Provides barrier coverage with a 25 m x 5 m (80 ft x 16 ft) pattern. Shipped in packages of three. Bosch Security Systems B.V.
Detectors and Accessories | Accessories | 297 OMLR93‑3 Long‑range Mirror PC1A Weather Enclosure 5 Ordering Information Provides long-range coverage with a 21 m x 3 m (70 ft x 10 ft) pattern. Shipped in packages of three. PC1A Weather Enclosure Protects detectors when mounted outside. The enclosure’s dimensions are 39.4 cm x 10.3 cm x 6 cm (15.5 in. x 4 in. x 2.4 in.). Shipped in packages of two.
298 | Detectors and Accessories | Accessories PEH‑2 Heater Environmental Considerations Operating Temperature: -25°C to +60°C (-13°F to +140°F) Relative Humidity (RH): Up to 95% Surface Temperature: +55°C (131°F) Power Requirements Power Supply Voltage: 20 VDC to 28 VDC non-polarized Current Draw: 350 mA maximum when power is applied 110 mA during operation (for each heater) Backup Power Requirements: 4 hours (440 mAh) minimum required for UL Certificated Installations 5 Ordering Information
Detectors and Accessories | Accessories | 299 TP161 Trim Plate TP160 Trim Plate 5 A light gray trim plate used when mounting the detector over a standard single-gang box. A black trim plate used when mounting the sensor over a standard single-gang box. Ordering Information Ordering Information TP160 Trim Plate A light gray trim plate used when mounting the detector over a standard single-gang box. www.boschsecurity.
Bosch Security Systems B.V. www.boschsecurity.
6 LSN Peripherals www.boschsecurity.com LSN Motion PIR/Microwave 302 LSN Seismic 322 LSN Glassbreak 325 LSN Smoke 327 LSN Magnetic Contacts 343 LSN Holdup 366 LSN Expansion Modules 367 LSN Display Panels 381 LSN Power Supplies 383 Bosch Security Systems B.V.
302 | LSN Peripherals | LSN Motion PIR/Microwave ISP‑PPR1‑WA16x Professional Series LSN PIR Detectors with Anti‑mask The self-locking two-piece enclosure, built-in bubble level, flexible mounting height, and three optional mounting brackets simplify installation and reduce service time. System Overview LSN Technology This detector is a two-wire unit for use with the Bosch Local Security Network system (LSN and LSN Improved).
LSN Peripherals | LSN Motion PIR/Microwave | 303 MANTIS Anti-mask Technology Flexible Topologies MANTIS (Multi-point Anti-mask with Integrated Spray detection) uses patented prism lenses and active infrared detection to provide industry-leading protection against all known forms of attack. MANTIS complies with the latest worldwide regulatory standards for detecting objects covering or placed in front of the detector.
304 | LSN Peripherals | LSN Motion PIR/Microwave Installation/Configuration Notes Mounting Considerations The recommended mounting height is 2 m to 3 m (7 ft to 10 ft). Use an optional B328 Gimbal-mount Bracket or B335-3 Low-profile Swivel-mount Bracket to surface-mount the detector on a flat wall or in a corner. Use an optional B338 Universal Ceiling Bracket to mount the detector on the ceiling. Wiring Considerations Recommended wire size is 0.2 mm2 to 1 mm2 (26 AWG to 16 AWG).
LSN Peripherals | LSN Motion PIR/Microwave | 305 Ordering Information ISP‑PPR1‑WA16G LSN PIR Detector with Anti‑mask 10.525 GHz frequency. ISP-PPR1-WA16G ISP‑PPR1‑WA16H LSN PIR Detector with Anti‑mask 10.588 GHz frequency. For use in France and the United Kingdom. ISP-PPR1-WA16H ISP‑PPR1‑WA16K LSN PIR Detector with Anti‑mask 9.35 GHz frequency. ISP-PPR1-WA16K Accessories B328 Gimbal‑mount Bracket Mounts on a single-gang box and allows rotation of a detector. Wires are hidden inside.
306 | LSN Peripherals | LSN Motion PIR/Microwave ISP‑PDL1‑WA18x Professional Series LSN TriTech+ Detectors with Anti‑mask MANTIS anti-mask technology makes obscuring the detector view nearly impossible for intruders. Sensor data fusion technology ensures that alarm conditions are based on precise information. The powerful combination of unique features in the Professional Series delivers superior catch performance and virtually eliminates false alarms.
LSN Peripherals | LSN Motion PIR/Microwave | 307 Range Adaptive Radar Remote Self Test The microwave transceiver automatically adjusts its detection thresholds based on input from the PIR sensors. Integrating the target distance information from the PIR significantly reduces false alarms from the microwave Doppler radar. When the control panel sends a remote self test message to the detector, the detector tests its detection systems.
308 | LSN Peripherals | LSN Motion PIR/Microwave Installation/Configuration Notes Use an optional B328 Gimbal-mount Bracket or B335-3 Low-profile Swivel-mount Bracket to surface-mount the detector on a flat wall or in a corner. Use an optional B338 Universal Ceiling Bracket to mount the detector on the ceiling. Wiring Considerations Recommended wire size is 0.
LSN Peripherals | LSN Motion PIR/Microwave | 309 Ordering Information ISP‑PDL1‑WA18G LSN TriTech+ Detector with Anti‑mask 10.525 GHz frequency. ISP-PDL1-WA18G ISP‑PDL1‑WA18H LSN TriTech+ Detector with Anti‑mask 10.588 GHz frequency. For use in France and the United Kingdom. ISP-PDL1-WA18H ISP‑PDL1‑WA18K LSN TriTech+ Detector with Anti‑mask 9.35 GHz frequency. ISP-PDL1-WA18K Accessories B328 Gimbal‑mount Bracket Mounts on a single-gang box and allows rotation of a detector. Wires are hidden inside.
310 | LSN Peripherals | LSN Motion PIR/Microwave DS 935 LSN Infrared Motion Detector - Higher response sensitivity Note The detector is not equipped with an alarm log display. Due to the individual detector identification by the LSN control panel, this is no longer necessary.
LSN Peripherals | LSN Motion PIR/Microwave | 311 Swiveling mirror Technical Specifications LSN operating voltage Max. 33 V LSN current consumption 0.8 mA Monitoring area • • Wide-angle mirror 11 m x 11 m Long-range mirror 21 m x 3 m Installation height 2 m to 2.6 m Rates of movement • • Plan view Wide-angle mirror 0.2 to 3.0 m/s Long-range mirror 0.2 to 4.
312 | LSN Peripherals | LSN Motion PIR/Microwave DS840LSN TriTech PIR/ MW Dual Motion Detector PIR sensitivity settings Select one of the following sensitivity settings using the software in the LSN control panel: Standard sensitivity: Minimizes false alarms and is suitable for extreme temperatures. Intermediate sensitivity: Suitable for instances where an intruder only moves through a small section of the protected area. Normal surroundings are tolerated on this setting.
LSN Peripherals | LSN Motion PIR/Microwave | 313 Installation/Configuration Notes Microwave frequency Installation notes DS840LSN: 10.525 GHz The installation height is between 2.0 m and 2.6 m. DS840LSN-C: 10.588 GHz Note DS840LSN-F5: 9.35 GHz When using the B335 or B338 mount, the range can be impaired and the dead zones can be expanded. The detector can react in its monitoring area to movements or swift changes in temperature.
314 | LSN Peripherals | LSN Motion PIR/Microwave IR 200 LSN Infrared Motion Detector Sensitivity adjustments The sensitivity can be set at 3 levels using the DIP switch: the sensitivity setting "high value" must not be used in rooms with wall lengths of less than 5 m.
LSN Peripherals | LSN Motion PIR/Microwave | 315 The installation bracket (optional) can be used to swivel the detector around by +/-45° and to tilt it by +10°/-15° (not VdS compliant!). Note Plan view Do not remove the circuit board in the detector. Risk of damage! Installation height 6 Y Range y: central long-range zone X Range x: lateral long-range zone Wide-angle version • Greatest possible monitoring density by closely-spaced chessboard-type mirror with 16 zones and a 15 m range.
316 | LSN Peripherals | LSN Motion PIR/Microwave The detector requires a stable reference for the entire detection zone. The detection zone consists of two subzones (separated by the central level). The subzones cannot be referenced to different surfaces that may consist of differing materials. The middle level of a detection zone is in the detector's longitudinal axis, which is perpendicular to the installation surface (housing floor).
LSN Peripherals | LSN Motion PIR/Microwave | 317 IR 270 T LSNi Infrared Motion Detector, Antimask Latch (saving): The activated antimask message is stored until antimasking is reset. If the detector is ripped from the mounting surface or the cover is removed, a sabotage alert is triggered.
318 | LSN Peripherals | LSN Motion PIR/Microwave Plan view 6 Permissible: 1 Material A 2 Material B 3 Outside wall 4 Inside wall Parts Included Long-range version with IRS 272 (optional) Type Qty. Component At installation heights above 3 m, the detector should point downward at an angle of 2°. IR 270 T LSNi 1 Infrared motion detector Side view/top view Technical Specifications IR 270 T LSNi LSN operating voltage Max. 33 V DC Current consumption • Maximum current 2.
LSN Peripherals | LSN Motion PIR/Microwave | 319 Ordering Information IR 270 T LSNi Infrared Motion Detector, Antimask For monitoring rooms for unauthorized entry, 18 m wide-angle version with antimasking and look-down zone, 25 m long-range version with long-range mirror (optional) IR270 T LSNi 6 www.boschsecurity.com Bosch Security Systems B.V.
320 | LSN Peripherals | LSN Motion PIR/Microwave UP 370 T LSN Matchtec Detector, Antimask The detection zone of the detector corresponds to a maximum area of 50 m2 and is limited by walls, doors, windows etc. Detection zone settings: – Standard: detection area 7 m x 7 m – Reduced: detection area 5 m x 5 m The use of several detectors in the same room is possible. Note minimum distance between detectors! Detector system function In disarmed status, the ultrasound transmitter is switched off.
LSN Peripherals | LSN Motion PIR/Microwave | 321 Side view Parts Included Type Qty. Component UP 370 T LSN 1 Matchtec motion detector Technical Specifications Plan view Power supply 8.0 to 28.0 V DC (12 V nom.) Voltage monitoring Fault at < 6.5 to 7.9 V Current consumption (at 12 V) • • Standby 18 mA Alarm with LEDs 31 mA Current consumption of LSN part Approx. 1.6 mA Detection speed 0.1 to 4 m/s Ultrasound frequency (stable crystal) 25.
322 | LSN Peripherals | LSN Seismic GM 570 LSN Seismic Detector Temporary reduction in sensitivity To prevent false alarms caused by loud operational noises, e.g. use of the object intake mechanism on day/night vaults, the response sensitivity of the detector can be temporarily reduced to approx. 1/8 of the pre-set value via a control input (e.g. contact switch on the object intake mechanism).
LSN Peripherals | LSN Seismic | 323 The detection zone is identified as the surface of a mechanical obstruction (vault or wall of an armored cabinet) that is being monitored by a detector. The detection zone is highly dependent on the material of the object being monitored. Due to practical experience, the effective range for steel and iron-reinforced concrete is r = 4 m.
324 | LSN Peripherals | LSN Seismic • Acoustic insulation between inlet channel and night safe Coating the opening cover and the inside of the safe with sound-absorbing material Using plastic cash boxes • • Ordering Information GM 570 LSN Seismic Detector For monitoring vault doors, modular vaults and vault walls 4998085573 Parts Included Type Qty. Component GM 570 LSN 1 Seismic detector Technical Specifications 6 LSN operating voltage Max. 33 V_ LSN current consumption 2.
LSN Peripherals | LSN Glassbreak | 325 GBS 2036 LSN Passive Glass Break Detector Installation/Configuration Notes Functional tests can be conducted using a detector testing device. Alarm triggering is displayed at the control panel and also directly indicated on the detector. Installation notes The GBS 2036 LSN is stuck to level glass plates in rooms. If several glass break sensors are grouped together in a detector zone, each detector zone must be limited to 20 glass break sensors.
326 | LSN Peripherals | LSN Glassbreak • • Laminated glass Armored (wire insert) glass Parts Included Type Qty. Component GBS 2036 LSN 1 Passive glass break detector Technical Specifications 6 LSN operating voltage 15 V to 33 V Current consumption 0.56 mA Protection category IP 67 VdS environmental class III Permissible ambient temperature -25 °C to +70 °C Housing • • Material S-B Color White Dimensions • • Device (H x W x D) 37 x 19 x 12 mm Connection cable Ø 3.
LSN Peripherals | LSN Smoke | 327 MAGIC.SENS Automatic LSN Fire Detectors Functions Sensor technology and signal processing The individual sensors can be configured via the LSN network manually or using a timer. All sensor signals are analyzed continually by the internal evaluation electronics and are linked with each other. The link between the sensors means that the combined detectors can also be used where light smoke, steam or dust must be expected during the course of normal operation.
328 | LSN Peripherals | LSN Smoke Special features 6 Detector type The stable and robust detector base no longer has to be directed due to the centralized position of the individual display. OTC 410 OC 410 OT 400 E O 400 E T 400 E Drift compensation, optical part x x x x - The integrated strain relief for interfloor cables prevents the removal of cables from the terminal after installation. The Drift compensation, gas sensor x x - - - terminals for cable cross-sections up to 2.
LSN Peripherals | LSN Smoke | 329 - UEZ 2000 LSN Universal Fire Panel UGM 2020 Universal Security System Plus other fire panels and their receiver modules with identical connection conditions. Country-specific standards and guidelines must be observed during the planning phase.
330 | LSN Peripherals | LSN Smoke Ordering Information 6 FAA‑420‑RI Remote Indicator FAA-420-RI Mounting Bracket for Fire Detectors on False Floor Stilts FMX-DET-MB MK 400 Detector Console Console for DIBt compliant mounting of detectors above doors etc.
LSN Peripherals | LSN Smoke | 331 MAGIC.SENS Detector Base Sounders System Overview Pos. Description 1 Detector module 2 Sounder unit 3 Snap-fit hooks 4 Mounting base 6 Features ▶ Volume up to 100 dB(A) Functions ▶ Electronic tone generator integrated into the signaling device The electronic tone generator integrated into the signaling device can produce 11 different tones (including DIN tones conforming to DIN 33404 and EN 457). ▶ 11 different tone variants can be selected (incl.
332 | LSN Peripherals | LSN Smoke • The current consumption depends on the tone type selected and is maximum 20 mA. MSS 300 ws Detector Base Sounder White • Control from the C point of the deployed MAGIC.SENS fire detector • When the detector is reset in the event of an alarm, the sounder is not reset. MSS 300 ws EC Detector Base Sounder White • Control of fire panel via an interface (not via the C point of the deployed MAGIC.
LSN Peripherals | LSN Smoke | 333 MAGIC.SENS Detector Base Sounders GLT/LSN Control MSS300-WH-EC GLT GLT by the C point of the fire by the fire panel via an detector interface MSS 400 LSN MSS 401 LSN LSN by the LSN by the LSN 9 V DC . . . 28 V DC 9 V DC . . . 28 V DC 15 V DC . . . 30 V DC 15 V DC . . . 30 V DC external power supply external power supply LSN LSN (max. 1.025 mA) and external power supply 1 mA 1 mA 2 mA 2 mA (AUX) max. 20 mA max. 20 mA max. 20 mA max.
334 | LSN Peripherals | LSN Smoke FAP‑520 Automatic Fire Detectors LSN improved version The detectors and trim rings in the "transparent with color inserts" version are supplied complete with reversible printed color ring sets, offering a choice of 16 colors for individual color matching.
LSN Peripherals | LSN Smoke | 335 Improved LSN features The 520 Series Fire Detectors offer all the features of the improved LSN technology: • Interference effects from daylight and commercial lighting sources are filtered out with an optical daylight filter and by the use of electronic filtering and phase-locked rectification (ambient light stability: glare test DIN EN 54‑7). The various light-emitting and photo diodes of the sensor are individually controlled by the detector electronics.
336 | LSN Peripherals | LSN Smoke • Region Certification Europe CE FAP-520 / FAA-500-R CPD 0786-CPD-20201 FAP-O 520 / 520-P A minimum distance of 50 cm from lamps must be maintained. The detectors may not be mounted in a cone of light from lamps. The bases are equipped as standard with a spring which is suitable for installation of the detector in false ceilings.
LSN Peripherals | LSN Smoke | 337 • • • FAP-OC 520(-P) 180 g / 370 g Ordering Information FAP-O 520(-P) 170 g / 360 g Accessories Trim Ring 30 g / 60 g FAA‑500‑TR-W Trim Ring, White for 500 and 520 Series Fire Detectors FAA-500-TR-W Environmental conditions Permissible operating temperature FAA‑500‑TR‑P Trim Ring, Transparent with Color Inserts for 500 and 520 Series Fire Detectors FAA-500-TR-P FAA‑500 LSN Base for installation of the FAP‑520 Fire Detector FAA-500 FAA‑500‑R LSN Base with Re
338 | LSN Peripherals | LSN Smoke FAP‑520 Automatic Fire Detectors LSN improved version FAP-O 520 FAP-O 520-P FAP-OC 520 FAP-OC 520-P optical optical optical/chemical optical/chemical 15 V DC . . . 33 V DC 15 V DC . . . 33 V DC 15 V DC . . . 33 V DC 15 V DC . . . 33 V DC Current consumption < 3.26 mA < 3.26 mA < 3.26 mA < 3.26 mA Protection category IP 53 IP 53 IP 33 IP 33 -20 °C . . . +65 °C -20 °C . . . +65 °C -10 °C . . . +50 °C -10 °C . . . +50 °C max. 120 m² max.
LSN Peripherals | LSN Smoke | 339 FAP‑420/FAH‑420 Automatic Fire Detectors LSN improved version System Overview Operating mode Detector type FAPOTC 420 FAP-OT 420 FAPFAHO 420(KKW T 420(KKW) ) Combined x x - - Optical x x x - Thermo-max. x x - x Thermal differential x x - x Chemical (+ optical) x - - - Functions Sensor technology and signal processing The individual sensors can be configured via the LSN network manually or using a timer.
340 | LSN Peripherals | LSN Smoke Chemical sensor (CO gas sensor) The main function of the gas sensor is to detect carbon monoxide (CO) generated as a result of a fire, but it will also detect hydrogen (H) and nitrous monoxide (NO). The sensor signal value is proportional to the concentration of gas. The gas sensor delivers additional information to effectively suppress deceptive values.
LSN Peripherals | LSN Smoke | 341 Region Certification Hungary TMT Russia Detector type Parts Included TMT-19/2006 FAP-OT 420, FAP-OT 420 KKW, FAP-OTC 420 GOST Detector type Qty. Components TMT-17/2006 FAP-O 420, FAP-O 420 KKW FAP-OTC 420 1 Multisensor Detector Optical/Thermal/ Chemical TMT-18/2006 FAH-T 420, FAH-T 420 KKW FAP-OT 420 1 Multisensor Detector Optical/Thermal FAP-O 420 1 Optical Smoke Detector POCC DE.
342 | LSN Peripherals | LSN Smoke Planning Ordering Information Monitoring area FAA‑MSR 420 Detector Base with Relay FAA-MSR 420 FAA‑MS 420‑R‑SP Detector Base with Relay and Spring for use in Great Britain FAA-MS 420-R-SP MS 420 LSN Detector Base with Spring for use in Great Britain MS 420 SSK 400 Protective Dust Cover (packing unit = 10 units) SSK 400 TP4 400 Support Plate for Detector Identification (packing unit = 50 units) TP4 400 TP8 400 Support Plate for Detector Identification (packing
LSN Peripherals | LSN Magnetic Contacts | 343 EMK 36 LSN Built-in Magnetic Contact 1 Contact 2 Magnet Distances diagram 6 Features 1 Extraction ▶ VdS class B 2 Proximity switch part ▶ Head-on mounting Connecting LSN contacts • Each LSN contact is a physical LSN element (1 out of 127 possible per loop). • The length of LSN contact connection cables must be included when planning the total line length of the LSN loop, as LSN technology is incorporated in these detectors.
344 | LSN Peripherals | LSN Magnetic Contacts 1 Detector 2 High-Ohm multimeter Contact open: approx. 3 MOhm Contact closed: approx. 1 megaohm Note Only the intrusion contact can be checked in this way. The tamper switch of the Class C magnetic contact can be checked by the LSN control panel or with the LSN testing device (software version 3.x onward). 6 Parts Included Type Qty. Component EMK 36 LSN 1 Built-in magnetic contact incl.
LSN Peripherals | LSN Magnetic Contacts | 345 EMK 36 AT LSN SurfaceMount Magnetic Contact 1 Contact 2 Magnet Distances diagram (parallel mounting) 6 Features 1 Extraction ▶ LSN surface-mount magnetic contact 2 Proximity switch part ▶ VdS class B Connecting LSN contacts • Every LSN contact is a physical LSN element (1 out of 127 possible per loop).
346 | LSN Peripherals | LSN Magnetic Contacts magnetic contact can be checked by the LSN control panel or with the LSN testing device (software version 3.x onward). Parts Included Type Qty. Component EMK 36 AT LSN 1 Surface-mount magnetic contact incl. flange, sleeves, and surface-mounting housing with accessories Technical Specifications 6 Type of installation Surface mount, parallel LSN operating voltage 15 V to 33 V Current consumption 0.
LSN Peripherals | LSN Magnetic Contacts | 347 EMK 36 S LSN Built-In Magnetic Contact 1 Contact 2 Magnet Distances diagram 6 Features ▶ LSN flush-mount magnetic contact ▶ VdS class C ▶ Tamper switch ▶ Head-on mounting ▶ LSN perimeter protection Magnetic contacts are used for tear-off surveillance of doors and windows.
348 | LSN Peripherals | LSN Magnetic Contacts 1 Detector 2 High-Ohm multimeter Contact open: approx. 3 MOhm Contact closed: approx. 1 megaohm Note Only the intrusion contact can be checked in this way. The tamper switch of the Class C magnetic contact can be checked by the LSN control panel or with the LSN testing device (software version 3.x onward). 6 Parts Included Type Qty. Component EMK 36 S LSN 1 Built-in magnetic contact incl.
LSN Peripherals | LSN Magnetic Contacts | 349 MK 36 S LSN SurfaceMount Magnetic Contact 1 Contact 2 Magnet Distances diagram 6 Features ▶ LSN surface-mount magnetic contact ▶ VdS class C ▶ Tamper switch ▶ Parallel mounting ▶ LSN perimeter protection Magnetic contacts are used for tear-off surveillance of doors and windows.
350 | LSN Peripherals | LSN Magnetic Contacts 1 Detector 2 High-Ohm multimeter Contact open: approx. 3 MOhm Contact closed: approx. 1 megaohm Note Only the intrusion contact can be checked in this way. The tamper switch of the Class C magnetic contact can be checked by the LSN control panel or with the LSN testing device (software version 3.x onward). 6 Parts Included Type Qty. Component MK 36 S LSN 1 Surface-mount magnetic contact incl.
LSN Peripherals | LSN Magnetic Contacts | 351 MSE-LSN B Built-In Magnetic Contact • • • The length of LSN contact connection cables must be included when planning the total line length of the LSN loop, as LSN technology is incorporated in these detectors. Passive coupling elements for joining the connection cables to the installation cable must be placed as close as possible to the LSN contacts.
352 | LSN Peripherals | LSN Magnetic Contacts Protection category IP68 Wire colors aLSN: 2 x white b1LSN: brown b2LSN: yellow 6 Bosch Security Systems B.V. www.boschsecurity.
LSN Peripherals | LSN Magnetic Contacts | 353 MSA-LSN B Surface-Mount Magnetic Contact Features ▶ LSN surface-mount magnetic contact ▶ VdS class B ▶ Parallel or head-on surface mounting ▶ LSN perimeter protection Magnetic contacts are used for tear-off surveillance of doors and windows. 1 Contact 2 Magnet 3 Offset in the axial direction Connecting LSN contacts • Each LSN contact is a physical LSN element (1 out of 127 possible per loop).
354 | LSN Peripherals | LSN Magnetic Contacts Technical Specifications 6 Type of installation Surface mount, parallel or head-on Operating voltage Max. 33 V_ Reed contacts Normally open contact Switch tolerance ≥ 107 Magnet AlNiCo 500 Switch dimension: Ø 8 mm x 30 mm Magnet dimension: Ø 8 mm x 30 mm Installation distance 5 to 20 mm AG4 surface mounting housing (H x W x D) 12 x 11.8 x 42.8 mm Temperature range -25 °C to 70 °C Connection cable: 4 m, LiY(St) Y 4 x 0.
LSN Peripherals | LSN Magnetic Contacts | 355 MSE-LSN C Built-In Magnetic Contact • • • The length of LSN contact connection cables must be included when planning the total line length of the LSN loop, as LSN technology is incorporated in these detectors. Passive coupling elements for joining the connection cables to the installation cable must be placed as close as possible to the LSN contacts.
356 | LSN Peripherals | LSN Magnetic Contacts Protection category IP68 Wire colors aLSN: 2 x green b1LSN: brown b2LSN: yellow 6 Bosch Security Systems B.V. www.boschsecurity.
LSN Peripherals | LSN Magnetic Contacts | 357 MSA-LSN C Surface-Mount Magnetic Contact Features ▶ LSN surface-mount magnetic contact ▶ VdS class C ▶ Tamper switch ▶ Parallel or head-on surface mounting ▶ LSN perimeter protection Magnetic contacts are used for tear-off surveillance of doors and windows.
358 | LSN Peripherals | LSN Magnetic Contacts Parts Included Type Qty. Component MSA-LSN C 1 Surface-mount magnetic contact incl. 4 m cable and 2x AG4 surface mounting housing with accessories Technical Specifications 6 Type of installation Surface mount, parallel or head-on Operating voltage Max.
LSN Peripherals | LSN Magnetic Contacts | 359 AMK 4 LSN Shutter Door Contact Features ▶ Shutter door contact in LSN technology ▶ For connecting to the LSN intrusion control panel ▶ VdS class B ▶ High level of mechanical strength ▶ Large switch distance ▶ LSN perimeter protection LSN shutter door contacts are used to monitor rolling, sliding and garage doors.
360 | LSN Peripherals | LSN Magnetic Contacts Parts Included Type Qty. Component AMK 4 LSN 1 Shutter door contact with magnet and installation material, including metal tube Technical Specifications 6 Type of installation Surface mount LSN operating voltage 15 V to 33 V Current consumption 0.
LSN Peripherals | LSN Magnetic Contacts | 361 AMK 4 S LSN Shutter Door Contact Features ▶ Shutter door contact in LSN technology ▶ For connecting to the LSN intrusion control panel ▶ VdS class C ▶ Tamper switch ▶ High level of mechanical strength ▶ Large switch distance ▶ LSN perimeter protection LSN shutter door contacts are used to monitor rolling, sliding and garage doors.
362 | LSN Peripherals | LSN Magnetic Contacts Parts Included Type Qty. Component AMK 4 S LSN 1 Shutter door contact with magnet and installation material, including metal tube Technical Specifications 6 Type of installation Surface mount LSN operating voltage 15 V to 33 V Current consumption 0.
LSN Peripherals | LSN Magnetic Contacts | 363 SKA 100 LSN Bolt Contact • Passive coupling elements for joining the connection cables to the installation cable must be placed as close as possible to the LSN contacts. The 1 m connection cable with 2 m LSN cable length is included in the calculation of the LSN cable length (LSN is carried into the contacts and back out again). Connector boxes (optional) are classified as installation material.
364 | LSN Peripherals | LSN Magnetic Contacts Dimensions (H x W x D) • • • Without operating lever 37 x 9 x 19 mm With operating lever 74 x 10 x 19 mm Connection cable Ø 3.2 mm, length 4 m Wire colors aLSN1: green bLSN1: brown aLSN2: green bLSN2: yellow Ordering Information SKA 100 LSN Bolt Contact For monitoring perimeter door closure 4998014066 6 Bosch Security Systems B.V. www.boschsecurity.
LSN Peripherals | LSN Magnetic Contacts | 365 SKI 100 LSN Bolt Contact • Passive coupling elements for joining the connection cables to the installation cable must be placed as close as possible to the LSN contacts. The 1 m connection cable with 2 m LSN cable length is included in the calculation of the LSN cable length (LSN is carried into the contacts and back out again). Connector boxes (optional) are classified as installation material.
366 | LSN Peripherals | LSN Holdup ND 200 LSN Panic Button Housing • • Material ABS Color RAL 9002 (housing) Gray (cover) Weight Approx.
LSN Peripherals | LSN Expansion Modules | 367 IPB-IF100 LSN 16 Zone Expander Module Installation/Configuration Notes Control panels must be installed in accordance with the standards of series DIN VDE 0800 (VdS Classes A, B and C). When installing, extending, modifying and operating control panels in VdS Classes B and C, DIN VDE 0833 must be applied. In the case of control panels that need to fulfill the requirements of VdS Schadenverhütung, the guideline VdS 2311 must also be applied.
368 | LSN Peripherals | LSN Expansion Modules Ordering Information IPB-IF100 LSN 16 Zone Expander Module For monitored connection of conventional detectors (16 primary lines) and for controlling (8 control outputs) on the local security network LSN F01U512129 6 Bosch Security Systems B.V. www.boschsecurity.
LSN Peripherals | LSN Expansion Modules | 369 NAK 100 LSN Branch Interface Installation/Configuration Notes Coupler power supply The LSN part of all LSN elements (couplers and detectors) is supplied with power via the control panel's 2-wire LSN line. All LSN couplers are designed to loop through the power supply (+V, -V) of subsequent couplers.
370 | LSN Peripherals | LSN Expansion Modules EN 54 T2 environmental class I Ambient climate DIN 40040 R14 Permissible ambient temperature 0 °C to +50 °C Housing • • • Material Plastic, ABS Terluran Color Light gray, RAL 9002 Dimensions (H x W x D) 135 x 100 x 35.7 mm Weight Approx. 140 g Ordering Information 6 NAK 100 LSN Branch Interface For connecting a branch stub with other LSN bus elements to a loop or stub of the local security network LSN Bosch Security Systems B.V.
LSN Peripherals | LSN Expansion Modules | 371 NNK 110 LSN Emergency Call Coupler Certifications and Approvals Region Certification Europe CE NNK 100 LSN Germany VdS G 102069, C NNK 110 LSN Installation/Configuration Notes Power supply Features ▶ 4 primary lines ▶ 1 non-monitored line A second twin wire lead, referred to as +V/-V, is required to supply power to the remaining expansion module functions and any connected conventional emergency call detectors.
372 | LSN Peripherals | LSN Expansion Modules Connecting conventional detectors Technical Specifications Operating voltage • • 1 Control panel 2 LSN element 3 1-4 DC primary lines 4 Loop In local security networks, detection and control functions are performed via the LSN line. This means additional primary lines in the control panel are not required for control procedures. +12 V to +33 V Other expansion module func- +9 V to +30 V tions Current consumption 2.
LSN Peripherals | LSN Expansion Modules | 373 Current consumption per relay • • At 12 V 20 mA At 28 V 10 mA Ambient temperature 0 °C to +55 °C Protection category IP 40 Ordering Information NNK 110 LSN Emergency Call Coupler For monitored connection of conventional detectors (4 primary lines), to controls (3 control outputs) and a non-monitored line for closure monitoring on the local security network LSN 4998114146 6 www.boschsecurity.com Bosch Security Systems B.V.
374 | LSN Peripherals | LSN Expansion Modules NVK 100 LSN Coupler Installation/Configuration Notes All sensor technology in the arming device area can be connected to the NVK 100 LSN, for example: • • • • • Conventional emergency call detector Arming device Coded arming device Closure and release monitoring Intrusion surveillance A second pair of wires for additional power supply is necessary for the NVK 100 LSN.
LSN Peripherals | LSN Expansion Modules | 375 Installation When installing the KR 100 LSN, the factory-installed solder distributors must be removed. A maximum of four KR 100 LSNs can be installed per NVK 100 LSN. One solder distributor is supplied per two KR 100 LSNs. Coupler power supply The LSN part of all LSN elements (couplers and detectors) is supplied with power via the control panel's 2-wire LSN line. All LSN couplers are designed to loop through the power supply (+V, -V) of subsequent couplers.
376 | LSN Peripherals | LSN Expansion Modules Principle • • • • • 2 change-over contacts Potential-free Starting current Max. 5 A Permanent current Max. 2 A Switch-off current Max. 1 A Switching voltage Max. 60 V Switching performance Max.
LSN Peripherals | LSN Expansion Modules | 377 IC 400 LSN Universal Expander The module housing has a tamper contact that, if triggered, sends a unique message and is evaluated as a sabotage alert. Certifications and Approvals Region Certification Europe CE IC 400 LSN Germany VdS G 101162, C IC 400 LSN Installation/Configuration Notes Expansion module power supply The LSN part of all LSN elements (expansion modules and detectors) is supplied with power via the control panel's 2wire LSN line.
378 | LSN Peripherals | LSN Expansion Modules Outputs Control outputs Low: 0 to 0.5 V Imax = 0.1 mA Active High: 7 to 9 V Imax = 0.1 mA Standby Note The MAGS-S active glass break detector, the EKOM 11 contact-less transmitter and the UP 370 T Matchtec detector are not suitable for connection to the IC 400 LSN. Parts Included 6 Type Qty. Component IC 400 LSN 1 Universal expander Technical Specifications Operating voltage • • LSN part +12 V to +33 V Separate power supply 10.
LSN Peripherals | LSN Expansion Modules | 379 KD 55/1 LSN 2 Zone Expander Modules Installation/Configuration Notes Connecting conventional detectors KD 55/1 LSN 2 zone expander module with 2 DC primary lines. Up to 20 conventional detectors can be connected per primary line. In this case, the reports are transmitted from the conventional detector to the LSN coupler in analog mode. This means existing equipment can be extended with ease.
380 | LSN Peripherals | LSN Expansion Modules Technical Specifications Operating voltage +10 V to +33 V Current consumption (line supplied) Approx. 0.
LSN Peripherals | LSN Display Panels | 381 BAT 100 LSN Display Panel Functions The BAT 100 LSN display panel handles the display of faults and/or alarms for detectors or detector zones. Up to three ATG 100 LSN kits can be installed in the BAT 100 LSN housing. An ATG 100 LSN includes 32 red LEDs for alarm indications or 32 yellow LEDs for fault indications. Mixed equipment (red and yellow LEDs) of the display panel with different ATG 100 LSNs is possible. LED displays can be labeled using a printer.
382 | LSN Peripherals | LSN Display Panels Environmental conditions Planning example Permissible operating temperature -5 °C to +50 °C Permissible storage temperature -20 °C to +60 °C Special features LED flash frequency 0.
LSN Peripherals | LSN Power Supplies | 383 NEV 300 LSN power supply Features ▶ Can be connected to all LSN control panels (centralized or decentralized) ▶ A maximum of two 12 V/17 Ah batteries can be used ▶ Monitoring of mains and battery voltage ▶ Tamper protection (tamper contact) ▶ 3 freely programmable open collector outputs ▶ Slot for optional voltage converter (to 28 V) The NEV 300 LSN is an additional power supply for LSN control panels.
384 | LSN Peripherals | LSN Power Supplies • The LSN a/b line current, max. 100 mA, is supplied by the control panel. The NEV 300 LSN can be operated directly next to the control panel (centralized) or remotely (decentralized). Installation cable for LSN technology: J-Y(St)Y Shielding (drain wire) must be routed to the ground connectors for each LSN line. There must be no connection between the housing potential and the LSN cable shielding.
7 Conettix - Information Transport Solutions www.boschsecurity.com Conettix - Receiver/Gateway 386 Conettix - Receiver/Gateway Accessories 399 Conettix GSM 407 Conettix IP 409 Conettix - AT2000/ATE 417 Bosch Security Systems B.V.
386 | Conettix - Information Transport Solutions | Conettix - Receiver/Gateway Conettix D6600 Communications Receiver/Gateway System Overview PSTN Communications Configuration This configuration uses existing telephone lines. A control panel's signal transmits over a PSTN analog telephone line to the D6600. The D6600 translates the signal to a common data format and sends the signal through Ethernet LAN, WAN, or RS-232 to a central station automation system.
Conettix - Information Transport Solutions | Conettix - Receiver/Gateway | 387 • • • • • • • • • • • • • • • • • • CFSK BELL/V.21 FBI Superfast Franklin/Sescoa ITI Radionics BFSK Radionics Hex Radionics Modem II Radionics Modem IIe/IIIa2 RB2000 SIA ADT SIA V.
388 | Conettix - Information Transport Solutions | Conettix - Receiver/Gateway Supervision and Programming with Network Communications The protected premises sends supervision messages to the D6600 at a programmed rate. Users can program the supervision rate to be 5 seconds to 1275 seconds. The D6600 acknowledges the supervision message, providing end-to-end security. If authentication and encryption algorithms detect potentially damaging activity, they alert the central station operator.
Conettix - Information Transport Solutions | Conettix - Receiver/Gateway | 389 Technical Specifications Trademarks Electrical Microsoft®, Windows®, and Windows NT® are registered trademarks of Microsoft Corporation in the United States and/or other countries. Power Requirements AC Nominal Operating Range: 120 V or 230 V AC Maximum Operating Range: 100 VAC to 120 VAC, 220 VAC to 230 VAC, 50 Hz or 60 Hz, 2.
390 | Conettix - Information Transport Solutions | Conettix - Receiver/Gateway Ordering Information Software Options Conettix D6200CD CD‑ROM Provides software for programming, operating, simulating, and demonstrations. Includes PDF documentation files for hardware and software relating to the Conettix Communications Receiver/Gateway. D6200CD 7 Bosch Security Systems B.V. www.boschsecurity.
Conettix - Information Transport Solutions | Conettix - Receiver/Gateway | 391 Conettix D6100 Communications Receiver/Gateway Edition, Windows Me, Windows NT®, Windows 2000, and Windows XP.
392 | Conettix - Information Transport Solutions | Conettix - Receiver/Gateway • • • • • • • • • • • • • • • • CFSK BELL/V.21 FBI Superfast Franklin/Sescoa ITI Radionics BFSK Radionics Hex Radionics Modem II Radionics Modem IIe/IIIa2 SIA ADT SIA V.21 Silent Knight Fast Silent Knight FSK Standard Pulse Formats Sur-Gard DTMF Telim Veritech FSK PSTN Communications 7 The D6100 connects directly to automation computers. Users can use the automation system or the D6100 keypad to acknowledge events.
Conettix - Information Transport Solutions | Conettix - Receiver/Gateway | 393 Inputs and Outputs Countries: For Automation Computer Connec- One RS-232 interface port COM3 tion: Hungary For External Serial Printer, PC, Mo- One RS-232 interface port COM4 dem, or Network Connection: India For Parallel Printer Connection: One parallel printer port Number of Programmable Inputs: Two (wire harness included) Number of Programmable Outputs: Two (wire harness included) Trademarks Iceland D6100-02 Kit (
394 | Conettix - Information Transport Solutions | Conettix - Receiver/Gateway Ordering Information 7 Conettix D6100 Kit (230 VAC) Includes one D6100, one transformer 230 VAC, and one round pin-style plug.
Conettix - Information Transport Solutions | Conettix - Receiver/Gateway | 395 Conettix D6100i Communications Receiver/Gateway Internet or Intranet Communications Configuration This configuration requires Conettix IP hardware components, uses existing Internet or intranet structures, and avoids additional telephone service costs. This configuration permits the Conettix D6200 Programming/ Administration Software to connect to the D6100i remotely.
396 | Conettix - Information Transport Solutions | Conettix - Receiver/Gateway • • • • • • • • CFSK BELL/V.21 FBI Superfast Franklin/Sescoa ITI Radionics BFSK Radionics Hex Radionics Modem II Radionics Modem IIe/IIIa2 • • • • • • • • SIA ADT SIA V.21 Silent Knight Fast Silent Knight FSK Standard Pulse Formats Sur-Gard DTMF Telim Veritech FSK PSTN Communications • Receives signals on two telephone lines simultaneously. • Independent, configurable communication format settings for each telephone line.
Conettix - Information Transport Solutions | Conettix - Receiver/Gateway | 397 Installation/Configuration Notes Current Requirements The D6100i and Monitoring Centers Battery Current: 330 mA The D6100i has extended edges so that installers can mount it easily into a standard 48.3 cm (19 in.) rack cabinet. Rack cabinets conserve floor space. UPS AC Standby Current: 180 mA Note Rack cabinets are sold separately by a variety of manufacturers. The D6100i connects directly to automation computers.
398 | Conettix - Information Transport Solutions | Conettix - Receiver/Gateway Ordering Information 7 Ordering Information Conettix D6100i Kit (230 VAC) Provides alarm communications over two PSTN lines or via a network. Supports two-way audio. Includes one D6100i, one transformer 230 VAC, and one round pin-style plug.
Conettix - Information Transport Solutions | Conettix - Receiver/Gateway Accessories | 399 Conettix D6200CD CD‑ROM D6600 CD ROM CD ROM that contains: • D6200 Programming Software, a programming application designed to work over a network or serial connection • D6202 Automation Simulator Software • D6600 Operating Software • D6600 Receiver Manuals • D6600 Conettix System Demonstration Software: use with up to 10 accounts The CD includes documentation for the following products: D6200 Programming Software
400 | Conettix - Information Transport Solutions | Conettix - Receiver/Gateway Accessories Conettix D6641 Telephone Line Card 7 Line card with digital signal processor (DSP) technology. Answers and decodes signals from up to four telephone lines simultaneously. The Conettix D6600 Communications Receiver/Gateway will accept up to eight telephone line cards to create a total of 32 telephone lines. Needs one Connetix D6645 Telephone Line Terminator Card.
Conettix - Information Transport Solutions | Conettix - Receiver/Gateway Accessories | 401 Conettix D6672 Com 1 Expansion Kit 7 Creates a third serial port on the Conettix D6600 Communications Receiver/Gateway. Provides a DB9 male connector and transient protection.
402 | Conettix - Information Transport Solutions | Conettix - Receiver/Gateway Accessories Conettix D6680 Ethernet Network Adapter Installation/Configuration Notes Compatibility Information Receivers: Conettix D6600 Communications Receiver/Gateway Location and Enclosures The D6680 must be installed in the same room as the D6600 and within 15.2 m (50 ft) of the D6600.
Conettix - Information Transport Solutions | Conettix - Receiver/Gateway Accessories | 403 Data Rates: Serial speed ranging from 300 bps to 115.2 kbps. Serial Line Formats: Characters: 7 or 8 data bits Stop bits: 1 or 2 Parity: Odd, even, none Modem Controls: RTS, CTS, DSR, DCD, DTR Flow Control: XON/XOFF CTS/RTS Management: HTTP (internal web server) SNMP (read only) Serial login Telnet login System Software : Flash ROM standard. Downloads from a TCP/ IP host (TFTP) or over serial port.
404 | Conettix - Information Transport Solutions | Conettix - Receiver/Gateway Accessories Conettix D6615 CPU Terminator Card 7 Modular design plug-in circuit board. Provides a shielded interface between the Conettix D6610 CPU Line Card and external connections to automation database computers and printers.
Conettix - Information Transport Solutions | Conettix - Receiver/Gateway Accessories | 405 P6602 Input and Output Cable P6603 Acknowledgement Button 7 Ordering Information P6602 Input and Output Cable Connects to the receiver and provides use of the input and output lines. P6602 Ordering Information P6603 Acknowledgement Button Spare acknowledgement button. www.boschsecurity.com P6603 Bosch Security Systems B.V.
406 | Conettix - Information Transport Solutions | Conettix - Receiver/Gateway Accessories Conettix D6100 Rack Mount Kit 7 Ordering Information Conettix D6100 Rack Mount Kit Standard rack mount kit measuring 48.3 cm (19 in.). Bosch Security Systems B.V. D6100RMK www.boschsecurity.
Conettix - Information Transport Solutions | Conettix GSM | 407 ITS-300GSM Communicator Features ▶ Monitoring of the telephone line statically and dynamically ▶ Backup path transmission via the GSM network in the event of a fault in the telephone line ▶ Calls from house phone via the GSM network are possible System Overview (1) House phone (2) Control panel (3) ITS-300GSM (4) Analog telephone network (5) GSM mobile network (6) Telephone network receiver (7) SMS receiver (8) Cell phone (A) Outgoing calls
408 | Conettix - Information Transport Solutions | Conettix GSM Transmission of own events If necessary, the device can transmit test calls and fault/ restoration of telephone line as an SMS message. Voltage range 10 to 14 V DC Dimensions 12.5 x 7 cm Programming Programming is carried out with a cell phone via entries on the SIM card. In transparent transmission, no programming is necessary for standard applications. Remote programming is possible with a cell phone via SMS messages.
Conettix - Information Transport Solutions | Conettix IP | 409 Conettix D6680 Ethernet Network Adapter Installation/Configuration Notes Compatibility Information Receivers: Conettix D6600 Communications Receiver/Gateway Location and Enclosures The D6680 must be installed in the same room as the D6600 and within 15.2 m (50 ft) of the D6600. Required for UL Central Station Protective Signaling, the D6680 must be mounted in a separate enclosure such as the AE1 (gray) or the AE2 (red).
410 | Conettix - Information Transport Solutions | Conettix IP 7 Data Rates: Serial speed ranging from 300 bps to 115.2 kbps. Serial Line Formats: Characters: 7 or 8 data bits Stop bits: 1 or 2 Parity: Odd, even, none Modem Controls: RTS, CTS, DSR, DCD, DTR Flow Control: XON/XOFF CTS/RTS Management: HTTP (internal web server) SNMP (read only) Serial login Telnet login System Software : Flash ROM standard. Downloads from a TCP/ IP host (TFTP) or over serial port.
Conettix - Information Transport Solutions | Conettix IP | 411 Conettix D6201 Series IP Security Keys Installation/Configuration Notes D6200 Programming Software Requirements Version Reason 1.05 or higher Required for USB security key operation. 1.24 or higher Required to use one security key for each site. For older software versions, one security key is necessary for each computer running D6200 Programming Software.
412 | Conettix - Information Transport Solutions | Conettix IP Conettix C900V2 Dialer Capture Ethernet Module System Overview When the dialer has a message to report, the C900V2 simulates dial tone and line voltages, causing the dialer to behave as though it is connected to a monitoring center digital receiver through the PSTN. The C900V2 decodes and converts the transmitted dialer message to data for transport over any UDP/IP network.
Conettix - Information Transport Solutions | Conettix IP | 413 Functions Polling and Supervision ADT-SIA Conettix C900V2 polling helps the Conettix D6600 Communications Receiver/Gateway to perform supervision.
414 | Conettix - Information Transport Solutions | Conettix IP Australia A-Tick Canada IC USA FCC Note Ordering Information Part 15 Radiated/Conducted Emissions FM approval applies when the C900V2 is used with the Conettix D6600 Communications Receiver/Gateway. Conettix C900V2 Dialer Capture Ethernet Module Compatible with control panels using a standard digital dialer format. Provides end-to-end security.
Conettix - Information Transport Solutions | Conettix IP | 415 Conettix DX4020 Ethernet Network Interface Module System Overview 1. Compatible Control Panel 2. Compatible Control Panel Option Bus or SDI Bus Connection 3. Conettix DX4020 Ethernet Network Interface Module 4. Ethernet Network Connection to DX4020 5. Host PC running Conettix D6200 Programming/Administration Software Features 6.
416 | Conettix - Information Transport Solutions | Conettix IP Certifications and Approvals Region Certification Europe CE USA 89/336/EEC, EN55022: 1997 +A2: 2002, EN50130-4: 1995 +A1: 1998 +A2: 2003, EN60950: 2000, EN61000-3-2: 2001, EN61000-3-3A1: 2001, EN61000-4-2: 1995 +A1: 1998 +A2: 2001, EN61000-4-3: 1996 +A1: 1998 +A2: 2000, EN61000-4-4: 1995 +A1: 2001 +A2: 2001, EN61000-4-5: 1995 +A1: 2001, EN61000-4-6: 1996 +A1: 2000, EN61000-4-11: 1994 +A1: 2001 UL AMCX: Central Station Alarm Units (UL1610
Conettix - Information Transport Solutions | Conettix - AT2000/ATE | 417 AT 2000 Analog Transmission System The event storage for up to 31 events can be read out using a PC. AT 2000 AFS • In addition, the AT 2000 AFS can handle the remotecontrol of outputs with the BOSCH transmission procedure. • The four outputs (relays) can be controlled depending on the message line status (locally) and via remote control by reception and transmission equipment using the Bosch procedure.
418 | Conettix - Information Transport Solutions | Conettix - AT2000/ATE Ordering Information Housing versions and installation modules Load on switch contacts • • Max. output 30 W/60 VA (Ohm resistive load) Max.
Conettix - Information Transport Solutions | Conettix - AT2000/ATE | 419 AT 2000 ISDN Transmission System The AT 2000 ISDN can be activated via the serial S1 interface (optional) or the parallel S1 interface with 7 input line inputs. The outputs (relay) can be controlled depending on the message line status (locally) and via remote control according to VdS 2465 by reception and transmission equipment.
420 | Conettix - Information Transport Solutions | Conettix - AT2000/ATE Fire detection technology • Interface according to VDE 0833 part 2 can be provided optionally. Parts Included Type Qty. Component AT 2000 ISDN incl. housing and power supply 1 ISDN alarm transceiver with housing and power supply AT 2000 ISDN incl.
Conettix - Information Transport Solutions | Conettix - AT2000/ATE | 421 AT 2000 TSN ISDN Transmission System Functions Network access Transmission procedure ISDN network X.
422 | Conettix - Information Transport Solutions | Conettix - AT2000/ATE • • Operation using the primary multiplex connection S2M is not possible. The AT 2000 TSN ISDN communicator for danger alarms must be connected to the S0 bus as the first device. With this connection, it is possible for the AT 2000 TSN ISDN to send a message even in the event of tampering or damage to the bus wiring. ISDN PTP • The "constant monitoring" layer 1 feature is present by default for system access. • The max.
Conettix - Information Transport Solutions | Conettix - AT2000/ATE | 423 Ordering Information Housing version Power supply • • • • • • Protection class I Mains voltage 230 V (-15% to ±10%) Mains frequency 50 Hz (±10%) Mains current consumption 200 mA Battery (order separately) 12 V/1 x 10 Ah Backup time Max. 72 hrs.
424 | Conettix - Information Transport Solutions | Conettix - AT2000/ATE AT 2000 IP ISDN Transmission System Functions Network access Transmission procedure Transmission protocol Receiver Ethernet UDP/IP VdS 2465 Ethernet monitoring station ISDN network (B-channel) X.
Conettix - Information Transport Solutions | Conettix - AT2000/ATE | 425 • Connection monitoring is carried out via adjustable, cyclic polling between the AT 2000 IP ISDN and the IP receiver. In this way, faults in the transmission path are recognized and displayed on both sides. With a polling rate < 20 s there is constant line monitoring (quasidedicated line), which fulfills all VdS requirements for class C systems. Report transmission occurs if required. IP demand-driven connection (VdS 2465 prot.
426 | Conettix - Information Transport Solutions | Conettix - AT2000/ATE Ordering Information UAE 8/8 junction box, surface mounted Necessary if transmission devices need to be connected in front of existing end units 2799181572 Mounting kit AT 2000 (IP) in NZ 300 LSN For installing an AT 2000 installation module (and IP module) in NZ 300 LSN ITS-ATNZ300 7 Bosch Security Systems B.V. www.boschsecurity.
Conettix - Information Transport Solutions | Conettix - AT2000/ATE | 427 ATE TSN ISDN Alarm Receiver Features ▶ Receipt via ISDN B-channel or GSM network ▶ Receive protocol: VdS2465 (X.75, SMS, V.110) ▶ Installation variant for UGM 2020-EAPS6 The ATE TSN ISDN is an alarm receiver with alarm reception via the ISDN network and GSM radio network. Installation/Configuration Notes ISDN connection • The ATE TSN ISDN can only be connected with an "exclusive" multi-system connection (PMP).
428 | Conettix - Information Transport Solutions | Conettix - AT2000/ATE Ordering Information Product ID 4.998.066.838 Aircom Plus cable (SOHA) 4.998.066.839 Expansion module connector for the Aircom Plus cable (SOHA) ATE installation module • The ATE TSN ISDN installation module handles installation in the UGM 2020 EAPS6 alarm receipt central station. It serves to connect the alarm communicators AT 2000 ISDN and AT 2000 ISDN.
8 Wireless Local Security Network (wLSN) www.boschsecurity.com wLSN Peripherie 430 wLSN Accessories 458 Bosch Security Systems B.V.
430 | Wireless Local Security Network (wLSN) | wLSN Peripherie wLSN Hub Certifications and Approvals Region Certification Europe CE 1999/5/EC, IEC60950-1: 2001, EN60950-1:2001 +A11:2004, EN50130-4: 1996 +A1: 1998 +A2: 2003, EN61000-4-2: 1995 +A1: 1998 +A2: 2001, EN61000-4-3: 2002 +A1: 2003 +A2: 2005, EN61000-4-4: 1995 +A1: 2001 +A2: 2001, EN61000-4-5: 1995 +A1: 2001, EN61000-4-6: 1996 +A1: 2001 +A2: 2001 +A3: 2005, EN61000-4-11: 1994 +A1: 2001, EN55022/ANSI C63.4: 2003, ETSI EN 300 220-1 V1.3.
Wireless Local Security Network (wLSN) | wLSN Peripherie | 431 Mechanical Properties Ordering Information Color: Off-white Dimensions (H x W x D): ISW-BHB1-WXNO 8.1 cm x 10.0 cm x 3.1 cm (3.2 in. x 4.0 in. X 1.2 in.) wLSN Hub (Norwegian) Serves as the link between the wireless Local SecurityNetwork (wLSN) devices and the control panel ISW-BHB1-WXPL 12 VDC nominal from control panel, 7.
432 | Wireless Local Security Network (wLSN) | wLSN Peripherie wLSN Relay Module RF Signal Strength Mode Removing the device cover and pressing the tamper switch four times within 10 seconds of battery installation activates the RF signal strength mode. The LED lights steady for 5 sec and then begins to flash. A slow flash (approximately 1 sec on, 1 sec off) indicates insufficient signal reception.
Wireless Local Security Network (wLSN) | wLSN Peripherie | 433 Technical Specifications Environmental Considerations Environment: Indoor, dry EN50131-1: Environmental Class II Relative Humidity: Up to 95%, non-condensing Temperature (operating): -10°C to +55°C (+14°F to +131°F) Mechanical Properties Color: Off-white Dimensions (H x W x D): 12.6 cm x 7.5 cm x 4.5 cm (5.0 in. x 3.0 in. x 1.8 in.
434 | Wireless Local Security Network (wLSN) | wLSN Peripherie wLSN Siren (Indoor) RF Signal Strength Mode Removing the device cover and pressing the tamper switch four times within 10 seconds of battery installation activates the RF signal strength mode. The LED lights steady for 5 sec and then begins to flash. A slow flash (approximately 1 sec on, 1 sec off) indicates insufficient signal reception.
Wireless Local Security Network (wLSN) | wLSN Peripherie | 435 Parts Included Quant. Component 1 Siren 4 AA batteries (P/N: 16556) 1 Hardware pack 1 Literature pack Technical Specifications Environmental Considerations Environment: Indoor, dry EN50131-1 Environmental Class II Relative Humidity: Up to 95%, non-condensing Temperature (operating): -10°C to +55°C (+14°F to +131°F) Mechanical Properties Color: Off-white Dimensions (H x W x D): 12.6 cm x 7.5 cm x 4.5 cm (5.0 in. x 3.0 in.
436 | Wireless Local Security Network (wLSN) | wLSN Peripherie wLSN Door‑Window Contact Reed Contacts There is a reed contact on either side of the device, so the magnet assembly can be mounted within 12.7 mm (0.5 in.) of the device on either side. When the distance between the magnet and the internal reed switch of the wLSN DoorWindow Contact exceeds 12.7 mm (0.5 in.), an alarm signal is sent to the Hub and from there to the control panel.
Wireless Local Security Network (wLSN) | wLSN Peripherie | 437 Parts Included Quant.
438 | Wireless Local Security Network (wLSN) | wLSN Peripherie wLSN Smoke Detector for Europe Test-Silence Button Operation A Test-Silence Button allows performance of sounder and sensitivity tests and silencing of alarm sounder and trouble chirp. Refer to the wLSN Reference Guide (P/ N: F01U009440) for details.
Wireless Local Security Network (wLSN) | wLSN Peripherie | 439 Ordering Information Parts Included wLSN Smoke Detector for Europe Non-latching wireless detector for transmitting alarm signals to the wLSN Hub Quant.
440 | Wireless Local Security Network (wLSN) | wLSN Peripherie wLSN Glassbreak Detector RF Signal Strength Mode Removing the device cover and pressing the tamper switch four times within 10 seconds of battery installation activates the RF signal strength mode. The LED lights steady for 5 sec and then begins to flash. A slow flash (approximately 1 sec on, 1 sec off) indicates insufficient signal reception.
Wireless Local Security Network (wLSN) | wLSN Peripherie | 441 Glass Type Glass Thickness Power Requirements Plate 2.4 mm to 9.5 mm (0.09 in. to 0.38 in.) Battery Power Tempered 3.2 mm to 9.5 mm (0.13 in. to 0.38 in.) Laminated* 3.2 mm to 14.3 mm (0.13 in. to 0.56 in.) Battery Life: Up to 2 years under normal operating conditions Wired 6.4 mm (0.25 in.
442 | Wireless Local Security Network (wLSN) | wLSN Peripherie wLSN Inertia Sensor RF Signal Strength Mode Removing the device cover and pressing the tamper switch four times within 10 seconds of battery installation activates the RF signal strength mode. The LED lights steady for 5 sec and then begins to flash. A slow flash (approximately 1 sec on, 1 sec off) indicates insufficient signal reception.
Wireless Local Security Network (wLSN) | wLSN Peripherie | 443 Parts Included Quant.
444 | Wireless Local Security Network (wLSN) | wLSN Peripherie wLSN Dual Motion Detectors Functions Signal Processing The detectors use passive infrared and microwave technologies to provide an alarm condition when both fields of protection are simultaneously activated. Alarm signals must meet the signaling requirements of both technologies to activate an alarm. Microwave range is factory set, but can be adjusted.
Wireless Local Security Network (wLSN) | wLSN Peripherie | 445 Certifications and Approvals Region Certification Europe CE Belgium INCERT Side View Broad: 11 m x 11 m (35 ft x 35 ft) G and H models only: 1999/5/EC, IEC60950-1: 2001, EN60950-1:2001 +A11:2004, EN50130-4: 1996 +A1: 1998 +A2: 2003, EN61000-4-2: 1995 +A1: 1998 +A2: 2001, EN61000-4-3: 2002 +A1: 2003 +A2: 2005, EN61000-4-4: 1995 +A1: 2001 +A2: 2001, EN61000-4-5: 1995 +A1: 2001, EN61000-4-6: 1996 +A1: 2001 +A2: 2001 +A3: 2005, EN61000-4-11:
446 | Wireless Local Security Network (wLSN) | wLSN Peripherie Microwave Characteristics Frequency: ISW-BDL1-W11PGX: 10.525 GHz ISW-BDL1-W11PHX: 10.588 GHz ISW-BDL1-W11PKX: 9.350 GHz Range: 11 m (35 ft) Power Requirements Battery Power Battery Life: Up to 3.5 years under normal operating conditions.
Wireless Local Security Network (wLSN) | wLSN Peripherie | 447 wLSN PIR Motion Detector Draft and Insect Immunity The sealed optical chamber provides immunity to drafts and insects. Temperature Compensation Automatically monitors the ambient temperature and adjusts the signal processing to maintain proper catch performance in critical temperature ranges.
448 | Wireless Local Security Network (wLSN) | wLSN Peripherie • Coverage Patterns The RF transceiver has a range of approximately 1000 m (3000 ft) in open air. However, in normal operation, the actual RF range depends on building construction and other factors. Parts Included Quant.
Wireless Local Security Network (wLSN) | wLSN Peripherie | 449 Ordering Information wLSN PIR Motion Detector Supports 79 zones in eight layers to provide superior catch performance ISW-BPR1-W13PX Accessories Swiveling B335-3 low-profile mount Swiveling, low-profile, plastic mount for wall mounting. The vertical swivel range is +10° to -20°, while the horizontal swivel range is ±25°. Available in triple packs. B335-3 8 www.boschsecurity.com Bosch Security Systems B.V.
450 | Wireless Local Security Network (wLSN) | wLSN Peripherie wLSN Key Fob Certifications and Approvals Region Certification Europe CE 1999/5/EC, IEC60950-1: 2001, EN60950-1:2001 +A11:2004, EN50130-4: 1996 +A1: 1998 +A2: 2003, EN61000-4-2: 1995 +A1: 1998 +A2: 2001, EN61000-4-3: 2002 +A1: 2003 +A2: 2005, EN61000-4-4: 1995 +A1: 2001 +A2: 2001, EN61000-4-5: 1995 +A1: 2001, EN61000-4-6: 1996 +A1: 2001 +A2: 2001 +A3: 2005, EN61000-4-11: 1994 +A1: 2001, EN55022/ANSI C63.4: 2003, ETSI EN 300 220-1 V1.3.
Wireless Local Security Network (wLSN) | wLSN Peripherie | 451 Power Requirements Battery Power Battery Life: Up to 5 years under normal operating conditions. Battery Requirements: Two lithium button-cell batteries Recommended Replacements: Duracell® DL2032, Eveready® ECR2032, Maxell™ CR2032, Panasonic® CR2032, Rayovac® KECR2032, SANYO®® CR2032, Toshiba CR2032, VARTA CR2032 Voltage (supply): 2.3 VDC to 3.
452 | Wireless Local Security Network (wLSN) | wLSN Peripherie wLSN Mini Door‑Window Contact Certifications and Approvals Region Certification Europe CE 1999/5/EC, IEC60950-1: 2001, EN60950-1:2001 +A11:2004, EN50130-4: 1996 +A1: 1998 +A2: 2003, EN61000-4-2: 1995 +A1: 1998 +A2: 2001, EN61000-4-3: 2002 +A1: 2003 +A2: 2005, EN61000-4-4: 1995 +A1: 2001 +A2: 2001, EN61000-4-5: 1995 +A1: 2001, EN61000-4-6: 1996 +A1: 2001 +A2: 2001 +A3: 2005, EN61000-4-11: 1994 +A1: 2001, EN55022/ANSI C63.
Wireless Local Security Network (wLSN) | wLSN Peripherie | 453 Technical Specifications Environmental Considerations Environment: Indoor, dry EN50131-1: Environmental Class II Relative Humidity: Up to 95%, non-condensing Temperature (operating): -10°C to +55°C (+14°F to +131°F) Mechanical Properties Color: Off-white Dimensions (H x W x D) Contact Assembly: 82 mm x 22 mm x 20 mm (3.2 in. x 0.9 in. x 0.8 in.) Magnet Assembly: 24.5 mm x 19 mm x 13 mm (1 in. x 0.7 in. x 0.5 in.
454 | Wireless Local Security Network (wLSN) | wLSN Peripherie wLSN Recessed Door‑Window Contact Certifications and Approvals Region Certification Europe CE 1999/5/EC, IEC60950-1: 2001, EN60950-1:2001 +A11:2004, EN50130-4: 1996 +A1: 1998 +A2: 2003, EN61000-4-2: 1995 +A1: 1998 +A2: 2001, EN61000-4-3: 2002 +A1: 2003 +A2: 2005, EN61000-4-4: 1995 +A1: 2001 +A2: 2001, EN61000-4-5: 1995 +A1: 2001, EN61000-4-6: 1996 +A1: 2001 +A2: 2001 +A3: 2005, EN61000-4-11: 1994 +A1: 2001, EN55022/ANSI C63.
Wireless Local Security Network (wLSN) | wLSN Peripherie | 455 Technical Specifications Environmental Considerations Environment: Indoor, dry EN5013-1: Environmental Class II Relative Humidity: Up to 95%, non-condensing Temperature (operating): -10°C to +55°C (+14°F to +131°F) Mechanical Properties Color: Off-white Dimensions (H x W x D) Contact Assembly: 105 mm deep x 19 mm diameter (4.125 in. deep x 0.75 in. diameter) Magnet Assembly: 1.3 mm deep x 19 mm diameter (0.5 in. deep x 0.75 in.
456 | Wireless Local Security Network (wLSN) | wLSN Peripherie wLSN Water Sensor/ Low‑temperature Sensor Functions RF Signal Strength (RFSS) Mode The RFSS mode provides the ability to evaluate RF signal strength between the wLSN Hub and devices before, during, and after installation. Device LEDs flash to indicate the level of signal quality and, if used, the wLSN Installation Tool indicates signal strength.
Wireless Local Security Network (wLSN) | wLSN Peripherie | 457 Ordering Information Parts Included Quant.
458 | Wireless Local Security Network (wLSN) | wLSN Accessories wLSN Installation Tool 1. Go/No Go: indicates whether or not the tool is receiving a signal from the wLSN Hub of sufficient strength to ensure reception by a wireless device located at that site 2. Packet Success Rate: indicates signal strength by the number of bars shown and the number of packets received by the tool (three packets are sent from the wLSN Hub every four seconds).
Wireless Local Security Network (wLSN) | wLSN Accessories | 459 Mounting Considerations The required region-specific transformers have 1.8 m (6 ft) cords. Position the docking units near a wall outlet in order to plug in the transformer. Note Refer to the wLSN Installation Tool Installation Instructions (P/N: F01U008748) for instructions on connecting the transformers to the docking stations.
460 | Wireless Local Security Network (wLSN) | wLSN Accessories ISW-BIT1-HBX (European Transformer) Frequency: 50 Hz Voltage (input): 230 VAC to 240 VAC Voltage (output): without load: 16.5 VDC ± 5% ISW-BIT1-HCX (United States Transformer) Frequency: 60 Hz Voltage (input): 120 VAC Voltage (output): without load: 13.5 VDC ± 5% Trademarks SANYO® is a registered trademark of SANYO North America Corporation.
DSRF Premises Wireless www.boschsecurity.com 9 Bosch DSRF Receivers 462 Bosch DSRF Transmitters 468 Bosch Security Systems B.V.
462 | DSRF Premises Wireless | Bosch DSRF Receivers RF3212 Series RF Receivers Certifications and Approvals Region Certification Europe CE RF312E: 1999/5/EC, EN60950: 1993 +A1 +A2 +A3 +A4, EN300220-1: 1997, EN300683: 1997 RF3212E: 1999/5/EC, EN60950 1992 (2nd edition) +A1 (1993) +A2 (1993) +A3 (1995) +A4 (1997), EN55022-1 Class B (1999), EN55024 (1998), EN50130-4 (1995) +A1 (1998) +A2 (2003), EN61000-4-2 (1995), EN61000-4-3 (1997), EN61000-4-4 (1995), EN61000-4-5 (1995), EN61000-4-6 (1997), EN61000-4-
DSRF Premises Wireless | Bosch DSRF Receivers | 463 Reception Characteristics RF3212 Frequency: 304.00 MHz Range (open air): 91 m (300 ft) nominal Up to 274 m (900 ft) if jam is off RF3212E Frequency: 433.42 MHz Range (open air): 305 m (1000 ft) Ordering Information RF3212E RF Receiver (433.42 MHz) 433.42 MHz version of the RF3212 RF Receiver. RF3212E 9 www.boschsecurity.com Bosch Security Systems B.V.
464 | DSRF Premises Wireless | Bosch DSRF Receivers RF3222E RF Receiver (433.
DSRF Premises Wireless | Bosch DSRF Receivers | 465 Technical Specifications Environmental Considerations Temperature (operating): 0°C to +66°C Mechanical Properties Dimensions including antennas: 25.6 cm x 15.2 cm x 3 cm Power Requirements Current: 30 mA, nominal Voltage: 12 V, nominal Trademarks TriTech® is a registered trademark of Bosch Security Systems in the United States. Ordering Information RF3222E RF Receiver (433.
466 | DSRF Premises Wireless | Bosch DSRF Receivers RF3227E RF Receiver (433.
DSRF Premises Wireless | Bosch DSRF Receivers | 467 Power Requirements Current Draw: 30 mA nominal Voltage (Input): 12 VDC Reception Characteristics Frequency: 433.42 MHz Range: 305 m Trademarks TriTech®® is a registered trademark of Bosch Security Systems in the United States. Ordering Information RF3227E RF Receiver (433.42 MHz) Receives RF signals from up to 96 wireless devices RF3227E 9 www.boschsecurity.com Bosch Security Systems B.V.
468 | DSRF Premises Wireless | Bosch DSRF Transmitters RF280THS Series Wireless Photoelectric Smoke Detectors Functions Chamber Check Self Diagnostics The Chamber Check Self Diagnostics automatic sensitivity test feature indicates when the detector is outside the factory calibrated specifications. The installer can easily determine which detectors require attention, reducing service costs. The detector alerts users when the detector is dirty, reducing false alarms.
DSRF Premises Wireless | Bosch DSRF Transmitters | 469 Transmission Characteristics Region Certification USA UL RF280THS only: UROX: Smoke - Automatic Fire Detectors (UL268 and A) Frequency Band CSFM RF280THS only: 7272-1615: 214 July 2008 RF280THS: 304.00 MHz RF280ETHS: 433.42 MHz FCC RF280THS only: ESV-0407-4 Trademarks IC RF280THS only: 12491021131 Chamber Check® is a registered trademark of Bosch Security Systems in the United States.
470 | DSRF Premises Wireless | Bosch DSRF Transmitters RF835 Series Wireless TriTech Detectors Functions Signal Processing Uses passive infrared and microwave technologies to provide an alarm condition when both fields of protection are simultaneously activated. Alarm signals must meet the signaling requirements of both technologies to activate an alarm. Microwave range is factory set, but can be adjusted if desired.
DSRF Premises Wireless | Bosch DSRF Transmitters | 471 Coverage Region Certification USA UL RF835 only: ANSR: Intrusion Detection Units (UL639) Canada IC RF835 only: 12491021658 China CCC RF835-CHI: 2004031901000037 DS835E: 20040319001000037-1 Brazil ANATEL RF835E only: 0255-06-1855 Australia RF835 complies with Australian EMC Europe RF835E and RF835E-C comply with EN50131‑1, Grade 2 USA RF835 complies with Federal Communications Commission (FCC) Installation/Configuration Notes Compat
472 | DSRF Premises Wireless | Bosch DSRF Transmitters Transmission Characteristics RF835 Microwave: 10.525 GHz RF Transmission: 304.00 MHz RF835E Microwave: 10.525 GHz RF Transmission: 433.42 MHz RF835E-C Microwave: 10.588 GHz RF Transmission 433.42 MHz Trademarks Eveready® is a registered trademark of Eveready Battery Company, Inc. Duracell® is a registered trademark of the Gillette Company, USA, in the United States and/or other countries.
DSRF Premises Wireless | Bosch DSRF Transmitters | 473 RF940E Wireless PIR Detector Installation/Configuration Notes Compatibility Information The RF940E detector is compatible with the following combinations of receivers and control panels: Receivers Control Panels RF3212E Solution Ultima 844, 862, and 880 control panels, CC488 control panels RF3213E VR-8 control panels RF3222E DS7400XiV4 control panels RF3227E DS7240, CC7240-A Solution 40 control panel RF3228E Marise control panels RF3249E
474 | DSRF Premises Wireless | Bosch DSRF Transmitters Coverage Ordering Information RF940E Wireless PIR Detector A high performance PIR motion sensor that uses advanced signal processing to provide outstanding catch performance RF940E Accessories Swiveling B335-3 low-profile mount Swiveling, low-profile, plastic mount for wall mounting. The vertical swivel range is +10° to -20°, while the horizontal swivel range is ±25°. Available in triple packs.
DSRF Premises Wireless | Bosch DSRF Transmitters | 475 RF1100E Glassbreak Transmitter • The RF1100E Glassbreak Transmitter has an LED ENABLE switch that activates or deactivates the LEDs. When the LED ENABLE switch is set to ON, a plastic orange tab protrudes from the side of the RF1100E Glassbreak Transmitter. The tab visually reminds you that the LEDs are active. Test Mode Activate the test mode locally using the RF1100E test pads or remotely using a Bosch 13-332 Sound Sensor Tester.
476 | DSRF Premises Wireless | Bosch DSRF Transmitters Glass Type Glass Thickness Mechanical Plate 0.24 cm to 0.95 cm Dimensions 12.2 cm x 10.5 cm x 3.3 cm Tempered 0.32 cm to 0.95 cm Frequency: 433.42 MHz Laminated 0.32 cm to 1.4 cm Protected only if both panes of unit are broken Environmental Wired 0.64 Temperature (operating): Trademarks Sensitivity Settings Sensitivity Setting Range Duracell® is a registered trademark of The Gillette Company. Maximum 7.
DSRF Premises Wireless | Bosch DSRF Transmitters | 477 RF3332 Series Key Fobs Certifications and Approvals Region Certification Europe CE RF3332E: 1999/5/EC, EN60950 1992 (2nd edition) +A1 (1993) +A2 (1993) +A3 (1995) +A4 (1997), EN55022-1 Class B (1999), EN55024 (1998), EN50130-4 (1995) +A1 (1998) +A2 (2003), EN61000-4-2 (1995), EN61000-4-3 (1997), EN61000-4-4 (1995), EN61000-4-5 (1995), EN61000-4-6 (1997), EN61000-4-8 (1994), EN61000-4-11 (1994), EN301489-3 (2000), ETS300683 (1997), EN300222-1 (1997
478 | DSRF Premises Wireless | Bosch DSRF Transmitters Mechanical Properties Dimensions: 3.8 cm x 6.3 cm x 1.3 cm (1.5 in. x 2.5 in. x 0.5 in.) Power Requirements Batteries: Two 3 VDC lithium batteries Battery Life: Approximately 5 years under normal operating conditions with recommended battery types Transmission Characteristics Maximum RF Power: Less than 10 mW Frequency RF3332E: 433.42 MHz RF3332: 304.
DSRF Premises Wireless | Bosch DSRF Transmitters | 479 RF3334 Series Key Fobs Certifications and Approvals Region Certification Europe CE RF3334E: 1999/5/EC, EN60950 1992 (2nd edition) +A1 (1993) +A2 (1993) +A3 (1995) +A4 (1997), EN55022-1 Class B (1999), EN55024 (1998), EN50130-4 (1995) +A1 (1998) +A2 (2003), EN61000-4-2 (1995), EN61000-4-3 (1997), EN61000-4-4 (1995), EN61000-4-5 (1995), EN61000-4-6 (1997), EN61000-4-8 (1994), EN61000-4-11 (1994), EN301489-3 (2000), ETS300683 (1997), EN300222-1 (1997
480 | DSRF Premises Wireless | Bosch DSRF Transmitters Power Requirements Batteries: Two 3 VDC lithium batteries Battery Life: 5 to 6 years under normal operating conditions with recommended battery types Transmission Characteristics Frequency RF3334: 304.00 MHz RF3334E: 433.42 MHz Trademarks Duracell® is a registered trademark of the Gillette Company, USA, in the United States and/or other countries. Eveready® is a registered trademark of Eveready Battery Company, Inc.
DSRF Premises Wireless | Bosch DSRF Transmitters | 481 RF3401 Series RF Point Transmitters Certifications and Approvals Region Certification Europe CE RF3401E: 1999/5/EC, EN60950 1992 (2nd edition) +A1 (1993) +A2 (1993) +A3 (1995) +A4 (1997), EN55022-1 Class B (1999), EN55024 (1998), EN50130-4 (1995) +A1 (1998) +A2 (2003), EN61000-4-2 (1995), EN61000-4-3 (1997), EN61000-4-4 (1995), EN61000-4-5 (1995), EN61000-4-6 (1997), EN61000-4-8 (1994), EN61000-4-11 (1994), EN301489-3 (2000), ETS300683 (1997), EN3
482 | DSRF Premises Wireless | Bosch DSRF Transmitters Technical Specifications Environmental Considerations Relative Humidity: 0% to 95% (non-condensing) Temperature (operating): -29°C to +65°C (-20°F to +150°F) For UL listed requirements, the temperature range is 0°C to +49°C (+32°F to +120°F) Mechanical Properties Dimensions: 8.26 cm x 3.56 cm x 1.91 cm (3.25 in. x 1.4 in. x 0.75 in.
DSRF Premises Wireless | Bosch DSRF Transmitters | 483 RF3405E Wireless (RF) Inertia Transmitter Certifications and Approvals Region Certification Europe CE 1999/5/EC, EN60950: 2000, EN61000-4-2: 1998, EN61000-4-3: 2000, EN300220-1: 1997 Brazil ANATEL 1164-06-1855 Installation/Configuration Notes Features ▶ Internal magnetic reed switch ▶ Supervised external loop ▶ Gross or minor attack movement settings ▶ Test mode Mounting Considerations • The maximum range of the inertia transmitter, in open
484 | DSRF Premises Wireless | Bosch DSRF Transmitters Trademarks Duracell® is a registered trademark of the Gillette Company, USA, in the United States and/or other countries. Energizer® is a registered trademark of Eveready Battery Company, Inc. Panasonic® is a registered trademark of Matsushita Electric Industrial Co., Ltd. Ordering Information RF3405E Wireless (RF) Inertia Transmitter Monitors doors and windows via an inertia sensor RF3405E 9 Bosch Security Systems B.V. www.boschsecurity.
DSRF Premises Wireless | Bosch DSRF Transmitters | 485 RF3501LE Panic Transmitter (433.
486 | DSRF Premises Wireless | Bosch DSRF Transmitters Trademarks Duracell® is a registered trademark of the Gillette Company, USA, in the United States and/or other countries. Eveready® is a registered trademark of Eveready Battery Company, Inc. Panasonic® is a registered trademark of Matsushita Electric Industrial Co., Ltd. Ordering Information RF3501LE Panic Transmitter (433.42 MHz) Single-button, wireless, panic transmitter with LED and fluorescent case. Can be worn on a necklace or clip.
DSRF Premises Wireless | Bosch DSRF Transmitters | 487 RF3503E Panic‑Medical Fob Receivers Control Panels RF3228E Marise RF3249E DA (Abacus) Recommended Batteries The following batteries are recommended for use with the RF3503E Transmitter: Duracell® DLCR2, Eveready® EL1CR2, or SANYO® CR2. Battery Life Battery life is approximately 5 yr under normal use. Use only the specified replacement batteries for the longest battery life.
Bosch Security Systems B.V. www.boschsecurity.
10 Signaling Devices Signaling Devices www.boschsecurity.com 490 Bosch Security Systems B.V.
490 | Signaling Devices | Signaling Devices BES External Signaling Device, Audio/Visual Certifications and Approvals Region Certification Europe CE BES Germany VdS G 197024, C BES A/O G 197023, C BES A Installation/Configuration Notes The danger signal zone is split into warning and emergency signals. DIN 33404, Parts 1 and 3 must be observed when planning for the fire alarm.
Signaling Devices | Signaling Devices | 491 Ordering Information BES External Signaling Device, Audio/ Visual For acoustic alarm signaling or with a red strobe light for visual alarm signaling 3002102450 BES external signaling device, audio For acoustic alarm signaling 3002102452 Parts Included Type Qty. Component BES audio/visual 1 External signaling device with optical display BES audio 1 External signaling device Technical Specifications Sound level Min.
492 | Signaling Devices | Signaling Devices BL 200 Strobes Certifications and Approvals Region Certification Europe CE BL 200 Germany VdS G 207104 BL 200 Poland CNBOP 0148/2008 BL 200 Russia GOST POCC DE.C313B06300 Installation/Configuration Notes • The Strobes are suitable for mounting in interior and protected exterior areas. The upper section of the signaling device is connected to the base by a bayonet lock.
Signaling Devices | Signaling Devices | 493 Special features Flash strength • • 12 V DC 0.7 J 24 V DC 1.
494 | Index A ADB Spring-loaded bolts for wooden windows ADM 2000 Spring-loaded mechanism AE1 Standard Enclosure (Gray) AE20 Universal Plastic Enclosure AE3 Large Enclosure (Gray) AMK 4 LSN Shutter Door Contact AMK 4 S Z Shutter Door Contact AMK 4 Z Overhead door contact AMK 4 S LSN Shutter Door Contact AT 2000 Analog Transmission System AT 2000 IP ISDN Transmission System AT 2000 ISDN Transmission System AT 2000 TSN ISDN Transmission System ATE TSN ISDN Alarm Receiver 265 264 98 99 98 359 285 284 361 417
Index | 495 EMK EMK EMK EMK EMK 36 36 46 46 46 LSN Built-in Magnetic Contact S LSN Built-In Magnetic Contact AT Z Surface-Mount Magnetic Contact S Z Flush-Mount Magnetic Contact Z Built-in magnetic contact 343 347 278 259 261 F F220 Heat Detectors F220 Photoelectric Smoke Detectors F220‑B6 Series Conventional Detector Bases F220‑B6RS 24 VDC Four‑wire Detector Base with Sounder FAP‑420/FAH‑420 Automatic Fire Detectors LSN improved version FAP‑520 Automatic Fire Detectors LSN improved version 234 231 23
496 | Index N V NAK 100 LSN Branch Interface 369 ND 100 GLT Panic Button 230 ND 200 LSN Panic Button 366 NEV 300 LSN power supply 108,383 NNK 110 LSN Emergency Call Coupler 371 NVK 100 LSN Coupler 374 NZ 300 LSN Hold-up and Intrusion Control Panel 63 VR8 Desktop Alarm System O OA120‑2 Mirror OD850 Series Outdoor TriTech Detectors OLR92‑3 Long‑range Lens OMB77‑3 Barrier Mirror OMLR77‑3 Long‑range Mirror OMLR93‑3 Long‑range Mirror 295 183 295 296 296 297 P P6601 Battery Cable P6602 Input and Output Cab
Tradition of quality and innovation name has stood for quality and reliability. Bosch Security Systems 2007 For over 100 years, the Bosch proudly offers a wide range of fire, intrusion, social alarm, CCTV, systems and components to help you find the solution for any application. We are the global supplier of choice for innovative technology backed by the highest level of service and support. When you need solutions you can rely on, choose Bosch.