Gas Type Conversion
1 Gas Type Conversion
For models: 250SX, 250SXO, GWH 635 ES, GWH
635 ESO, GWH 2400 E, GWH 2400 EO only
A. Preparation
B 1. Tools needed:
flat and Phillips screwdrivers
#40 Torx driver
digital combustion analyzer
B 2. Turn power switch to off position and unplug water
heater.
B 3. Remove cover.
B 4. Remove control board access cover (Fig. 1).
Fig. 1
B 5. Remove lower wire harness from control board.
B 6. Loosen yellow painted Philips screw and cover
should rotate down revealing a brass slotted screw
(Fig. 2).
Fig. 2
B 7. Remove yellow painted # 40 Torx cover from the
front of the gas valve revealing a plastic #40 Torx
screw (Fig. 3).
Fig. 3
LP AND NG ARE EXTEMELY
FLAMMABLE SO TAKE EXTRA
PRECAUTIONS WHEN
PERFORMING ANY WORK TO THE
HEATER.
i
PROCEDURE MUST BE
PERFORMED BY A LICENSED GAS
TECHNICIAN.
2 SCREWS
TO REMOVE