Step 3: Anchor outdoor unit
The outdoor unit can be anchored to to a commercially available mounting pad on
the ground or to a wall-mounted bracket (both sold separately).
Unit mounting dimensions
The following is a list of diff erent outdoor unit sizes and the distance between their
mounting feet. Prepare the installation base of the unit according to the dimensions
below.
WARNING:
Never mount this unit directly on the ground. It must be
anchored according to the guidance provided in these
instructions, and/or local building codes.
W
A
B
D
Air inlet
Air outlet
Air inlet
Figure 24
Outdoor Model
Outdoor Unit Dimensions (mm/in) Mounting Dimensions
W x H x D Distance A (mm/in) Distance B (mm/in)
Climate 5000 AAS-009-0CS, Climate 5000 AAS-009-1CS 770x555x300 (30.3”x21.85”x11.81”) 487 (19.2”) 298 (11.73”)
Climate 5000 AAS-012-0CS, Climate 5000 AAS-012-1CS 800x554x333 (31.5”x21.8”x13.1”) 514 (20.24”) 340 (13.39”)
Climate 5000 AAS-018-1CS 845x702x363 (33.25”x27.63”x14.29”) 540 (21.26”) 350 (13.8”)
Climate 5000 AAS-024-1CS 946x810x420 (37.21”x31.9”x16.53”) 673 (26.5”) 403 (15.87”)
Table 3