3. Rotate the drain joint 90° until it clicks in place facing the front of the unit.
4. Connect a drain hose extension (not included) to the drain joint to redirect
water from the unit during heating mode.
If the drain joint doesn’t come with a rubber seal (see Fig. 23, pos. B), do the
following:
1. Insert the drain joint into the hole in the base pan of the unit. The drain joint
will click in place.
2. Connect a drain hose extension (not included) to the drain joint to redirect
water from the unit during heating mode.
NOTICE
In cold climates, make sure that the drain hose is as vertical
as possible to ensure swift water drainage. If water drains too
slowly, it can freeze in the hose and flood the unit.
Seal
Drain joint
(A) (B)
Base pan hole of
outdoor unit
Seal
Figure 23