Use and Care Manual

| 7
User Manual
Bosch Climate 5000 Series Wall Mounted Ductless Split Air Conditioner / Heat Pump (06.2022)
2.2 Achieving Optimal Performance
When your air conditioner is used outside of the following temperature
ranges, certain safety protection features may activate and cause the
unit to disable.
Optimal performance for the COOL, HEAT, and DRY modes can be achieved in
the following temperature ranges. When your air conditioner is used outside of
these ranges, certain safety protection features will activate and cause the unit to
perform less than optimally.
Optimal performance temperature ranges
COOL mode HEAT mode
DRY mode
Room Temperature
17ºC - 32ºC 0ºC - 30ºC 10ºC - 32ºC
63ºF - 90ºF 32ºF - 86ºF 50ºF - 90ºF
Outdoor
Temperature
Regular (9K ~ 24K)
-25ºC - 50ºC -25ºC - 30ºC 0ºC - 50ºC
-13ºF - 122ºF -13ºF - 86ºF 32ºF - 122ºF
Max Performance
(9K ~ 24K)
-30ºC - 50ºC -30ºC - 30ºC 0ºC - 50ºC
-22ºF - 122ºF -22ºF - 86ºF 32ºF - 122ºF
LCAC (30K, 36K)
-15ºC - 50ºC -15ºC - 30ºC 0ºC - 50ºC
5ºF - 122ºF 5ºF - 86ºF 32ºF - 122ºF
Table 1
When the outside temperature is below 0°C (32°F ), we strongly
recommend keeping the unit plugged in at all times to ensure smooth
ongoing performance. A base pan heater is used in the outdoor unit to
prevent ice build-up. Ice may build up if the unit is unplugged.
To further optimize the performance of your unit, do the following:
Keep doors and windows closed.
Limit energy usage by using TIMER ON and TIMER OFF functions.
Do not block air inlets or outlets.
Regularly inspect and clean air filters.
2.3 Other Features
Auto-Restart
If the unit loses power, it will automatically restart with the prior settings
once power has been restored.
Louver Angle Memory
When turning on your unit, the louver will automatically resume its former
angle.
Refrigerant Leakage Detection
The indoor unit will automatically display "EL0C" when it detects
refrigerant leakage.
Active Clean Function
The Active Clean Technology washes away dust, mold, and grease that
may cause odors when it adheres to the heat exchanger by automatically
freezing and then rapidly thawing the frost. A “pi-pi” sound will be heard.
The Active clean operation is used to produce more condensed water to
improve the cleaning eff ect, and the cold air will blow out. After cleaning,
the internal wind wheel then keeps operating with hot air to blow-dry the
evaporator, thus preventing the growth of mold and keeping the inside
clean. -- When this function is turned on, the indoor unit display window
appears “CL ” , after 20 to 45 minutes, the unit will turn off automatically
and cancel Active Clean function.
ECO Intelligent (Single Zone Only)
The system is controlled intelligently under Intelligent eye mode. It can
detect the people’s activities in the room. In cooling/Heating/Auto mode,
when you are away for 30 minutes, the unit will automatically lower the
frequency to save energy. And the unit will automatically start and resume
operation if sensing human activity again.
Humidity Control (Single Zone Only)
The unit is able to increase the comfortable level by lowering humidity
in your home. The unit off ers a better temperature and humidity control
solution in the dry mode, the room temperature can be maintained
accurately as set temperature while the moisture is being removed.
The Intelligent Eye and Humidity Control feature may not be available in
all confi gurations.
Sleep Operation
The SLEEP function is used to decrease energy use while you sleep (and
don’t need the same temperature settings to stay comfortable). This
function can only be activated via remote control. And the Sleep function
is not available in FAN or DRY mode.
Press the SLEEP button when you are ready to go to sleep. When in COOL
mode, the unit will increase the temperature by 1°C (2°F) after 1 hour,
and will increase an additional 1°C (2°F) after another hour. When in HEAT
mode, the unit will decrease the temperature by 1°C (2°F) after 1 hour,
and will decrease an additional 1°C (2°F) after another hour.
Figure 2
Set
temperature
1hr
1hr
Keep
running
SLEEP Operation
Saving energy during sleep
Heat mode( -1 °C/2 °F) per hour
for the first two hours
Cool mode(+1 °C/2 °F) per hour
for the first two hours
For a detailed explanation of your unit’s advanced functionality (such as
TURBO mode and its self-cleaning functions), refer to the Remote
Control Manual.
For multi-split air conditioners, the following functions are not available:
Active clean function, Silence feature, Refrigerant leakage detection
function and Eco feature.