IMPORTANT: Please discard previous User Instructions and retain only the 'Worcester Outdoor Pack' user instructions.
EXCELLENCE COMES AS STANDARD Thank you for purchasing a Worcester oil-fired central heating boiler. Worcester oil boilers are made by Worcester Heat Systems and the strictest quality control standards ever demanded are applied throughout every stage of production. Indeed, Worcester Heat Systems have led the field in innovative boiler design and performance for more than 30 years.
GENERAL INFORMATION To ensure you get the very best from your new Worcester oil boiler, please read these notes and instructions carefully. Discard the user instructions provided within the white boiler casing of the boiler and only use the Outdoor Pack user instructions and boiler customer care guide. ELECTRICAL CONNECTION The electrical supply to this appliance must satisfy the latest edition IEE wiring regulations and any local regulations, which apply.
NOTE: The Outdoor Pack is not load bearing; it only provides weather proofing for the boiler inside. SERIAL NUMBER: In any contact with Worcester Heat Systems quote your boiler serial number, model and that it is fitted within the Outdoor Pack. This will help identify spare parts and also avoid confusion and delays during any service call-out. You will find the boiler serial number on the front of the control facia as shown in fig.1.
HOW TO START YOUR BOILER (See Fig. 1.) (a) Switch on the electrical mains supply to the boiler. (b) Ensure that any external controls connected to the boiler, such as a room thermostat, are on a high setting. (c) If a programmer is fitted set it to the correct time of day and position the selectors to ON. (d) Ensure the switch on the Outdoor control box is in the ‘run’ position. (e) Turn the thermostat control knob to the desired position (see Fig. 2: temperature control).
TO SWITCH OFF YOUR BOILER During normal operation your boiler can be switched off at the programmer, where fitted. A frost thermostat is fitted as standard to protect the boiler only in frost conditions. If there is a possibility the central heating /hot water system may be exposed to frost conditions, an additional frost thermostat should be fitted.
pressing the button located underneath the control box. (See fig 1.) If the overheat thermostat persistently cuts out then your boiler requires attention and you should call either your installer or a service engineer. FROST THERMOSTAT A frost thermostat is fitted as standard to protect the boiler only in frost conditions. If there is a possibility the central heating /hot water system may be exposed to frost conditions, an additional frost thermostat should be fitted.
If, after checking through the points suggested, there is still a fault you should call your local Worcester Heat Systems Service Centre. Arrangements will be made for an engineer to call as soon as possible. Call-Out charges All of Worcester Heat Systems’ field service engineers are factory trained.
FAULT FINDER If your boiler is not operating, it is suggested that you go through the following simple checks before either calling your installer or Worcester Heat Systems. SYMPTOM POSSIBLE CAUSE Boiler does not fire and There is no demand for heat burner lockout lamp is from external control not illuminated equipment CHECK/REMEDY • Check the programmer is programmed for hot water and/or central heating and reprogramme if necessary. (See programmer operating instructions).
MAINTAINING YOUR BOILER’S EFFICIENCY & PERFORMANCE Your new Worcester Danesmoor or Worcester Bosch oil-fired boiler represents a long-term investment in a reliable, high quality product. In order to realise its maximum working life, and to ensure it continues to operate at peak efficiency and performance, it is essential that your boiler receives regular, competent servicing and annual maintenance checks beyond the initial 24 month guarantee period.
YOUR WORCESTER DANESMOOR / WORCESTER BOSCH GUARANTEE This appliance is guaranteed against faulty materials or workmanship for a period of twenty four calendar months from the date of installation subject to the following conditions and exceptions. 1. That during the currency of this guarantee any components of the unit which are proved to be faulty or defective in manufacture will be exchanged or repaired free of material charges and free of labour charges by Worcester Heat Systems Limited. 2.
Worcester Heat Systems Limited. Cotswold Way, Warndon, Worcester WR4 9SW. Telephone: (01905) 754624. Fax: (01905) 754619. Technical Service Helpline 08705 266241. www.worcester-bosch.co.