Application's Manual
Data subject to change without notice | 01.2011 BOSCH THERMOTECHNOLOGY CORPORATION
THERM Tankless Water Heater Applications Manual | 13
7 Outdoor Installation
The models listed below are designed to be installed indoors.
However, they are approved for outdoor installation when installed
with the Outdoor Kit (part# BTOK):
830 ES
940 ES/ESO
C 1050 ES
C 1210 ES/ESC
Outdoor Kit (BTOK) installation:
The installation of this outdoor kit (BTOK) is required when
installing any of the above appliances outdoors.
Outdoor cap easily retrofi ts to these indoor models.
Exterior water piping should be protected if short term freezing
conditions could exist.
Not for use in areas routinely exposed to freezing temperatures.
Minimum clearances:
Ref. Description
Min.
distances
A
Directly below or adjacent to
an opening; operable
windows, doors and any fresh
air openings
≥ 1 ft
B
C
D ≥ 1 ft
E
Below a gutter, sanitary
pipework, eaves or overhang
≥ 3 ft
F ≥ 1 ft
G
From a gas meter or gas
regulator
≥ 3 ft
Outdoor Installation Clearances
Above ground
From any adjacent wall
Source: NFPA 54 National Fuel Gas CodeANSI Z223.1
Installation on wood siding
Installation on vinyl siding:
3½΄
≥12" ≥12"
≥12"