Installation Manual

6 720 644 930
Appliance details
5
Real-time diagnostics for troubleshooting/
informational purposes
LCD Display with backlight
On/Off and Temperature control switches
Reset button
Program button (Selectable temperature default)
Failure codes for easy diagnostics and repair
Easily removable one-piece cover
Built in freeze prevention.
Note: The freeze prevention kit is designed to provide
protection for the water heater down to approximately
5°F for short term conditions only. It will not protect the
appliance in areas where the temperature is routinely
expected to be below freezing.
- The freeze prevention kit will not protect plumbing out-
side the appliance from freezing. Precautions should be
taken.
Accessories (Bosch part #)
Optional wireless remote control accessory to
operate with the appliance (TSTAT2)
Cascading kit (77090003962)
Outdoor kit (BTOK)
External water filter (8703305356)
Gas conversion kit (8719002176)
Vertical vent kit (ESVVT)
Concentric vent /air intake kit (ESHCK)
Horizontal vent kit (4TWHVK3SII)
1)
Stainless steel bird screen (L2594)
(fits into a 3” PCV fitting - Intake vent).
Pipe Cover (PTPCES)
High temperature kit (7736500074)
Recess box kit (7736500043)
Pressure relief valve (FWL-2).
2.2 Specifications (Technical data)
Approved in US/Canada
Capacity
Maximum flow rate: 7.15 GPM (27 l/min) at a 45°F
(25°C) rise.
Maximum output
160,500 Btu/h (47.0 kW)
Maximum input
199,000 Btu/h (58.3 kW)
Efficiency in %
Thermal efficiency > 82%
Min. Input
19,900 Btu/h (5.8 kW)
Temperature Control
Selection range: 100°F (38°C) - 140°F (60°C)
Default temperature: 122°F (50°C)
Stability: +/- 2°F (+/- 1°C)
Gas Requirement
Gas connection (inches) - ¾”
Inlet gas pressure under operation (with a high hot
water flow rate)*
Propane: 8” - 13” water column
Natural Gas: 3.5” - 10.5” water column.
* To measure gas pressure, see Measuring Gas
Pressure, chapter 3.13, page 32.
Water
Hot water connection (inches) - ¾”
Cold water connection (inches) - ¾”
Water valve material: Polymer (PPS) (Polypropylene
Sulfid)
Minimum water flow: 0.5 gallon/minute (1,9 l/m).
Note: Activation varies with inlet water temperatures
from 0.5 - 1.6 gallon/minute (1,9 - 6.1 l/m).
Minimum recommended water pressure: 30 PSI
(2.07 bar).
Minimum well pressure 40 psi, see page 28.
Connections:
Bottom of heater
Combustion
NOx 40 Ng/J
(Nanograms of NOx (calculated as NO
2
) per
Joule of heat output).
CO 250 ppm (measured)
CO
2
level set from factory, see chapter 6.4, page 39.
1) 4TWHVK3S vent kit is compatible with this appliance
but requires the purchase of an additional 12" piece of
straight pipe to meet minimum vent length requirements.
The aluminum flex piping included with this kit is not
permissible for use with this appliance.
i
BOSCH is constantly improving its
products, therefore specifications are
subject to change without prior notice.