Data Sheet

Bosch Video Management System integration
With Bosch Video Management System (Bosch VMS)
and an intrusion system, the VMS operator has a single
user interface to monitor and control the intrusion
system combined with video surveillance. With Bosch
VMS and a control panel, the operator can, for
example:
View videos triggered by intrusion events, including
all relevant information such as areas, point, and user
show in the display with the event
View areas, points, outputs, and doors – with their
statuses – on the Bosch VMS map, providing the
exact location in the system.
Turn on (arm) and turn off (disarm) areas.
Bypass and unbypass points.
Requirements to integrate Bosch VMS with a control
panel:
A licensed Bosch VMS system using Professional
Editions v5.5 or higher or Bosch VMS Enterprise
Edition v5.5 or higher.
Expansion license to integrate the intrusion control
panel. One license needed per control panel. Order
number MBX-XINT-xx for the expansion license added
to a Bosch VMS base license. Refer to the Bosch
Video Management Software product page on the
Bosch website, www.boschsecurity.com.
Access to Remote Programming Software (RPS).
Certifications and approvals
Region Certification
USA ANSI/
SIA
CP-01-2010-Control Panel Standard -
Features for False Alarm Reduction
Region Certification
USA UL
UL UL 365 - Police Station Connected Bur-
glar Alarm Units
UL UL 609 - Standard for Local Burglar
Alarm Units and Systems
UL UL 636 - Holdup Alarm Units and Sys-
tems
UL UL 985 - Household Fire Warning Sys-
tem Units
UL UL 1023 - Household Burglar Alarm Sys-
tem Units
UL UL 1076 - Proprietary Burglar Alarm
Units and Systems
UL UL 1610 - Central Station Burglar Alarm
Units
CSFM see our website
FCC Part 15 Class B
Canada ULC
ULC CAN/ULC S303 - Local Burglar Alarm
Units and Systems
Region Certification
ULC CAN/ULC S304 - Standard for Signal Re-
ceiving Center and Premise Burglar
Alarm
ULC CAN/ULC S545 - Residential Fire Warn-
ing System Control Units
ULC ULC-ORD C1023 - Household Burglar
Alarm System Units
ULC ULC-ORD C1076 - Proprietary Burglar
Alarm Units and Systems
Installation/configuration notes
Compatible products
Keypads
B942/B942W Touch Screen Keypad (SDI2)
B930 ATM Style Alphanumeric Keypad (SDI2) (SDI2)
B921C Two-line Capacitive Keypad (SDI2)
B920 Two-line Alphanumeric Keypad (SDI2)
B915/B915I Basic Keypad (SDI2)
Transformers
CX4010 Plug-in Transformer (18 VAC 22 VA 60 Hz)
ICP‑TR1822‑CAN Plug‑in Transformer (110 VAC primary, 18 VAC 22 VA
secondary)
Enclosures
B10 Medium Control Panel Enclosure
B11 Small Control Panel Enclosure
B12 Mounting Plate for D8103 Enclosure
D2203 Enclosure
D8103 Universal Enclosure (requires a B12)
D8108A Attack Resistant Enclosure (requires a B12)
D8109 Fire Enclosure (requires a B12)
Accessories
B56 B56 Keypad Surface Mount Box
B96 Keypad Trim Bezel
B99 USB Direct Connect Cable
B501-10 Interconnect wiring cables (pack of 10)
Detectors
D285/TH Photoelectric Smoke Detector Heads
FCC-380 Carbon Monoxide Detector
Bosch conventional detectors, including Professional Series, Blue Line
Gen2, Blue Line, Classic Line, Commercial Line, and Ceiling Mount
motion detectors, as well as glass break, seismic, request-to-exit,
photoelectric, heat, and smoke detectors.
4 | B3512 Control Panels