Data Sheet

Region Certification
ULC ULC-ORD C1023 - Household Burglar
Alarm System Units
ULC ULC-ORD C1076 - Proprietary Burglar
Alarm Units and Systems
IC ICES-003 - Information Technology
Equipment (ITE)
Brazil ANATEL 1709-13-1855
Installation/configuration notes
Mounting considerations
Connect the B430 Plug-in Telephone Communicator to
any compatible control panel or interface module,
which can then be mounted in a variety of enclosures
for optimal situations.
Wiring considerations
The B430 connects to the control panel or interface
modules without tools or physical wiring for power. It
has an RJ-45 jack for plugging in the phone line
(PSTN).
Communication speed
The module communicates at 2400 baud maximum.
Compatibility
Control panels B9512G/B9512G-E
B6512
B8512G/B8512G-E
B5512/B5512E
B4512/B4512E
B3512/B3512E
Phone cords D161 Dual Modular Telephone Cord
D162 Modular Telephone Cord
Phone jack D166 Telephone Jack
Parts included
Quantity Component
1 B430 Plug-in Telephone Communicator
1 Literature pack
Technical specifications
Properties
Dimensions 2 in x 3.68 in x 0.60 in
(50 mm x 93.5 mm x 15.25 mm)
Weight 1.3 pounds (0.6 KG)
Environmental considerations
Relative humidity 5% to 93% at +32°C (+90°F)
Temperature (operating) 0°C to +49°C (+32°F to +120°F)
Power requirements
Current (maximum) Standby: 24 mA
Alarm: 24 mA
Voltage (operating) 12 VDC nominal
Ordering information
B430 Plug-in Telephone Communicator
Plug-in PSTN communication module for control panel
to central station receiver communication.
Order number B430
2 | B430 Plug-in Telephone Communicator