Quick Start Guide

SLOT
SLOT 2
Open 3.7 - 5.0 VD
C
Normal 2.0 - 3.0 VDC
Short 0.0 - 1.3 VDC
ETHERNET
100
BASE-T
LINK
USB
COMMU
NICATION M
ODULE 1
C
OUTPUT
B
SDI2
Device Bu
s
R Y G B
ON-BOARD POINTS
1 COM 2
3 COM
4
5
COM
6
7 COM 8
1 k
End of Line Resistor
s
OUTPUT A
OUTPUT A
OUTPUT A
18 VAC
BATTERY
AUX
- 12V +
AUX PWR
COM
DR
Y
J
umper Under Cover
ʊ
Communication Devices
Quick Start Guide
B5512/B4512/B3512
Control Panel
1
= PC direct, connect using AutoIP (Wi-Fi off, wait 2 min)
2
= PC direct, connect using Male A to Male A USB (B99)
3
= ‘E’ panel variants do not include on-board Ethernet
On-board Inputs and Outputs
SDI2 Specifi cations
Unshielded, 4 conductor, 22-12 gauge cable
Maximum cable length 1000’ single run, 7500’ system total
Allows a combination of home run, daisy chain and T-tapping wiring confi gurations
B10 Enclosure
B11 Enclosure
Need more help?
For detailed instructions, refer to the control panels
Installation and System Reference Guide (ISRG) chapter
number (ISRG #5.2 ) included on the CD provided with
the control panel.
Control Panel Mounting Locations
Attaching Mounting Clips
Technology
Location
ISRG
#
Terminal Description Specifi cation
18VAC
Transformer 18VAC 22VA Plug-in
Earth Ground Cold water pipe, or similar
+ BAT - Battery 12VDC 7Ah
NO C NC Output A(1) Switched AUX, COM, or Dry
COM AUX Aux Power 12VDC, 800mA
R Y G B SDI2 Bus
Keypads, SDI2 devices, terminal
and Quickconnect in parallel
1 COM 2 Alarm Inputs 1k
EOL
TMPR Tamper Optional tamper switch
B C
Outputs B(2),
C(3)
Open collector, 50mA,
active low
RESET Reset Switch
Hold 5 seconds to enter or
exit service mode
Heartbeat
Slow=normal, Rapid=service
mode
MODULE 1 Plug-in Communication module options
Reporting
Personal Notifi cations
Remote RPS Programming
Local RPS Programming
Remote Security App
Ethernet
3
On-board 7.5
Cellular
B44x
Plug-in
8.2
Telephone
B430
Plug-in
7
USB On-board 3.3.8
Transformer
2
1
SDI2 Device Type Options
Maximum # of Devices
Device Type Part # Description ISRG # B5512 B4512 B3512 Address Notes
Keypad
B915 2-line Basic 9.1.1
8* 8* 4* 01...08
Similar
device types
must use
different
addresses.
Different
device types
may use
the same
address.
* Maximum
number of
keypads and
RF receivers
in a single
system.
B920 2-line, LCD 9.1.2
B921C/W 2-line, Capacitive 9.1.3
B930 5-line, ATM LCD 9.1.4
B942 Touch Screen 9.1.5
I/O Expander
B208 8-input 13.1 4 2 0
01...08
B308 8-output 11.1 5 3 0
RF Receiver
B810 Bosch RADION 14.1
1* 1* 1* 1
B820 Inovonics 14.2
Power Supply
B520 12V DC, 2A 6.3 4 2 2 01...04
Remote Cellular
B450 B44x Plug-in Interface 8.4 1 1 1 1