Data Sheet

Event log
The event log stores local and reported events. The
event log includes information such as time, date,
event, area, point, and user. View the event log from a
keypad or use RPS to remotely retrieve event
information. When the event log reaches a
programmed threshold of stored events, it can send an
optional report to a receiver.
The log stores up to 127 local and reported events.
Scheduled events (SKEDs)
The internal clock and calendar start individually
scheduled events (SKEDs). SKEDs perform several
functions such as turn on or off, relay control, or point
bypassing.
The control panel offers:
The control panel offers:
Five scheduled events with up to 25 different
functions
Two opening windows and two closing windows
Two user group windows
Day-of-week, date-of-month, or holiday only schedules
One holiday schedule of 366 days (leap year)
Programming
Installers can perform limited programming on-site
with a keypad (critical parameters; such as account
IDs, central station and RPS IP addresses and phone
numbers, reporting formats, and more). They can also
do full programming on-site or remotely (attended or
unattended) with RPS. A programmable system
passcode prevents unauthorized remote programming.
Diagnostics
Keypads and RPS offer diagnostic help for monitoring
and troubleshooting. The diagnostics features allow
you to view the status of the wired and wireless
devices. The features provide the status of the control
panel and its connected devices, such as firmware
version, power, and missing conditions. View the
status of each area.
Remote Security Control app
The Remote Security Control (RSC) app allows users
to control their security systems remotely from their
devices. Users can:
Turn their security system On or Off
Turn specific areas On or Off
Control outputs for applications such as lighting
control
View live video from Bosch IP cameras
Grant access remotely by unlocking and locking doors
The app requires the installing dealer to create a
Remote Access Profile for users, and to install the
profile on their devices.
Bosch Video Management System integration
With Bosch Video Management System (Bosch VMS)
and an intrusion system, the VMS operator has a single
user interface to monitor and control the intrusion
system combined with video surveillance. With Bosch
VMS and a control panel, the operator can, for
example:
View videos triggered by intrusion events, including
all relevant information such as areas, point, and user
show in the display with the event.
View areas, points, outputs, and doors – with their
statuses – on the Bosch VMS map, providing the
exact location in the system.
Turn on (arm) and turn off (disarm) areas.
Bypass and unbypass points.
Requirements to integrate Bosch VMS with a control
panel:
A licensed Bosch VMS system using Professional
Editions v5.5 or higher or Bosch VMS Enterprise.
Edition v5.5 or higher.
Expansion license to integrate the intrusion control
panel. One license needed per control panel. Order
number MBX-XINT-xx for the expansion license added
to a Bosch VMS base license. Refer to the Bosch
Video Management Software product page on the
Bosch website, www.boschsecurity.com.
Access to Remote Programming Software (RPS).
Certifications and approvals
Region Regulatory compliance/quality marks
USA ANSI-
SIA
CP-01-2010-Control Panel Standard -
Features for False Alarm Reduction
Australia RCM ACMA
Europe CE EMC, LVD, RoHS [B6512, B5512,
B5512E, B4512, B4512E, B3512,
B3512E]
USA UL [B6512, B5512, B4512, B3512]
UL UL 365 - Police Station Connected Bur-
glar Alarm Units
UL UL 609 - Standard for Local Burglar
Alarm Units and Systems
UL UL 636 - Holdup Alarm Units and Sys-
tems
UL UL 985 - Household Fire Warning Sys-
tem Units
UL UL 1023 - Household Burglar Alarm Sys-
tem Units
UL UL 1076 - Proprietary Burglar Alarm
Units and Systems
UL UL 1610 - Central Station Burglar Alarm
Units
UL UL 1635 - Standard for Digital Alarm
Communicator System Units
CSFM see our website
FCC Part 15 Class B
Canada ULC {B6512, B5512, B4512, B3512]
ULC CAN/ULC S303 - Local Burglar Alarm
Units and Systems
ULC CAN/ULC S304 - Standard for Signal Re-
ceiving Center and Premise Burglar
Alarm
4 | B4512 Control Panels