Power Requirements
Current draw (maximum) Idle 125 mA; Alarm 155 mA
Output (alarm) 1.3 A at 12 VDC
Output (auxiliary, continuous
power, and switched auxiliary
combined):
800 mA at 12 VDC nominal
Voltage (operating): 12 VDC nominal
Voltage (AC): CX4010 UL Listed Class 2
Transformer 18 VAC 22 VA 60 HZ
Ordering information
B4512 IP control panel, 28 points
Supports up to 28 points, 3 on-board outputs, and 2
areas for intrusion, residential fire. On-board Ethernet.
Order number B4512
B4512E Control panel, 28 points, no IP
The B4512E is available only in kits.
For kits, refer to Quick Selection Guide (B Series Kits)
on the Documents tab of the control panel’s Product
Page at us.boschsecurity.com.
Order number B4512E
Accessories
B520 Auxiliary power supply module, 2A 12V
Provides auxiliary power to 12 VDC devices or to SDI2
modules.
Order number B520
B201 2-Wire Powered Loop
The module provides a single powered initiating device
circuit. The module supports compatible 12 V 2-wire
smoke detectors. It also supports connecting burglary
devices to the control panel.
Order number B201
B208 SDI2 8-Input Expansion Module
Provides 8 programmable inputs.
Order number B208
B308 SDI2 8-Output Expansion Module
Provides 8 programmable relays.
Order number B308
B810 RECEIVER-SDI2
Receives RF signals from RADION transmitters,
repeaters, and glassbreaks. Operates at 433.42 MHz.
For use with compatible SDI2 bus control panels.
Order number B810
D122 Dual battery harness, 17" 18AWG
Harness with circuit breaker. Connects two batteries
(in parallel) to a compatible control panel.
Order number D122
D122L Dual battery harness, 35'', 12V
Harness with circuit breaker and leads measuring
35 in. (89 cm). Connects two batteries (in parallel) to
a compatible control panel in a separate enclosure.
Order number D122L
D126 Battery, 12V 7Ah
A rechargeable sealed lead‑acid power supply used as
a secondary power supply or in auxiliary or ancillary
functions.
Order number D126
D1218 Battery, 12V 18Ah
The D1218 is a 12 V 18 Ah sealed lead‑acid battery
with two bolt-fastened terminals. It is used for standby
and auxiliary power. It connects to a compatible
control panel using a D122 or D122L Dual battery
harness.
Order number D1218
CX4010 Transformer, plug-in, 18V 22VA
For use in North America. 110 VAC primary voltage
input. 18 VAC, 22 VA secondary input.
Order number CX4010
ICP-TR1822-CAN Transformer, plug-in, 18V 22VA, Cana-
da
For use in Canada. 110 VAC primary voltage input. 18
VAC, 22 VA secondary input.
Order number ICP-TR1822-CAN
B8103 Universal enclosure, white
White steel enclosure measuring 41 cm x 41 cm x 9 cm
(16 in. x 16 in. x 3.5 in.).
Order number B8103
D8103 Steel enclosure, large, grey
Grey steel enclosure measuring 41 cm x 41 cm x 9 cm
(16 in. x 16 in. x 3.5 in.).
Order number D8103
D8108A Attack resistant enclosure, large, grey
Grey steel enclosure measuring 41 cm x 41 cm x 9 cm
(16 in. x 16 in. x 3.5 in.). UL Listed. Includes a lock and
key set.
Order number D8108A
D8109 Fire enclosure, 16x16x3.5", red
Red steel enclosure measuring 16 in. x 16 in. x 3.5 in.
(41 cm x 41 cm x 9 cm). UL Listed. Includes a lock and
key set.
Order number D8109
B10 Steel enclosure, medium, white
White, steel enclosure. Accepts an optional lock and
tamper switch. Measures 35.6 cm x 31.8 cm x 7.6 cm
(14 in x 12.5 in x 3 in).
Order number B10
7 | B4512 Control Panels