Data Sheet
Central monitoring stations provide 24-hour system
monitoring with access to vital services. Professional
security personnel can test the system, monitor
system activity, and alert the police, fire department,
or other emergency response teams if necessary.
Functions
Programmable outputs
• Three programmable on-board outputs; one high
current using a relay, and two trigger outputs
• Output A, with a contact rating of 3 Amps, can supply
up to 1.0 A total current from AUX PWR
• Outputs B and C sink up to 50 mA at 12 VDC
• Four alarm-output patterns
• Programmable bell test
Point response
• 20 custom point indexes
• Selectable point response time
• Cross point capability
• Fire alarm verification
• Dangerous gas indicator includes carbon monoxide
(NFPA 720)
• Watch mode
User interface
• Supervision of up to 8 keypads
• Custom keypad text is fully programmable through
RPS
• Full function menu including custom functions
• Authority by area and 32 character name for each
user
• 14 custom authority levels to restrict system features
that each user can access
• Programmable primary and secondary language by
user and keypad; select from English, Spanish,
French, and Portuguese
Area configurations
Link multiple areas to a shared area such as a lobby or
common entryway. The shared area then automatically
turns On (arms) when all associate areas are armed
and turns Off (disarms) when any one associate area
is disarmed. For higher security applications, the Area
Re-Arm feature guarantees that areas are always
rearmed, and are disarmed for no longer than a
specific, configurable, amount of time (for example,
service time).
Custom functions
For added convenience, the installer can program
custom functions that allow customers to complete
complex tasks with one simple action. For example, a
custom function can bypass a group of points and arm
the system, allowing the user to perform these
functions with one easy command. Users can activate
custom functions with a keypad, keyfob, token, or
card, or the control panel can activate a function in
reaction to a faulted point, or automatically through a
scheduled event (SKED).
Passcode security
• Two-man rule. Requires two people with two unique
passcodes to be present at the time of opening.
• Early ambush. Allows users to verify that the facility is
safe by requiring two passcodes. The control panel
sends a duress event if the user does not enter the
passcode a second time after inspecting the
premises.
• Dual authentication. Requires two forms of
identification before processing certain system
commands, including turning off the system and
opening doors. A standard system user must have a
passcode, a credential (token or card), and
appropriate command authority permissions.
Easy exit control
The control panel changes from one On (armed) state
to another without turning off (disarming) the system.
For example, if you change the state from Part On
(Perimeter Arm) to All On (Master Arm), the control
panel complies and reports the change. Easy Exit
Control reduces the number of keystrokes, simplifying
system operation.
Programmable passcode-controlled menu list
Passcode-controlled shortcuts provide users only with
the options and information pertinent to them,
simplifying system operation.
Flexible control
The system provides the flexibility to choose added
convenience or high security. For example, you can
restrict to a keypad's immediate local area turning on
(arming) and turning off (disarming) the system with a
passcode, even if the user has access to other areas.
This is particularly useful for high security areas,
where a user may have access to the area, but would
prefer to only turn off (disarm) the area individually
rather than with the rest of the system.
Monitor Delay/Delayed Response
Create a special point index that delays the reaction of
a point for a specified time (up to 1 hour in minutes
and seconds). This delay provides time for the
specified condition to reset before activating any
annunciation. The system can annunciate locally and
send a report, if desired. When the system is armed,
the point can respond like a normal point – providing
dual functionality. Use this feature to ensure that
perimeter doors have not been propped open, or to
monitor critical areas such as computer rooms and
safes, for example.
System users
The system supports up to 50 users. Each user can
have a personalized passcode, a wireless keyfob, and a
credential to control the system. You can assign
passcodes to one of 14 customized authority levels in
each area that can be restricted to operate only during
certain times. Programmable primary and secondary
language by user and keypad; select from English,
Spanish, French, and Portuguese.
2
| B5512 Control Panels