Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Certifications, approvals, listings, and safety
- Introduction
- System overview
- Installation checklist
- Control panel installation
- Power supply
- Telephone communications
- IP communications
- Keypads, keyswitches, keyfobs and transmitters
- Keypads
- B915 Basic Keypad
- B920 Two-line Alphanumeric Keypad
- B921C Two-line Capacitive Keypad with Inputs
- B930 ATM Style Alphanumeric Keypad
- B942 Touch Screen Keypad
- Shortcuts and custom functions
- Address settings
- Supervision
- Installation and control panel wiring (keypads)
- Sensor loops overview and wiring (B921C/B942/B942W only)
- Output wiring (B942/B942W only)
- Troubleshooting
- Keyswitches
- RADION keyfobs and Inovonics pendant transmitters
- Keypads
- On-board outputs
- Off-board outputs
- On-board points
- Off-board points
- Wireless modules
- Access control
- Program and test the control panel
- Control panel board overview
- System wiring diagrams
- Approved applications
- Keypad Installer menu
- [1] Program menu
- [1] Reporting > [1] Phone menu parameters
- [1] Reporting > [2] Network menu parameters
- [1] Reporting > [3] Routing menu parameters
- [1] Reporting > [4] Personal Note menu parameters
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [1] Module Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [2] Address Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [3] DNS Parameters menu
- [2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in module)
- [3] RPS > [1] RPS Passcode menu parameters
- [3] RPS > [2] RPS Phone Number menu parameters
- [3] RPS > [3] RPS IP Address menu parameters
- [3] RPS > [4] RPS Port Number menu parameters
- [4] Area Options menu parameters
- [5] Keypad menu parameters
- [6] Users menu parameters
- [7] Points menu parameters
- [8] Disable Programming menu
- [2] Wireless menu
- [1] RF Point Menu> [1] Enroll Point RFID
- [1] RF Point Menu> [2] Replace Point RFID
- [1] RF Point Menu> [3] Remove Point RFID
- [2] RF Repeater Menu > [1] Add Repeater
- [2] RF Repeater Menu > [2] Replace Repeater
- [2] RF Repeater Menu > [3] Remove Repeater
- [3] RF Diagnostic Menu > [1] RF Points
- [3] RF Diagnostic Menu > [2] RF Repeater Menu
- [3] Diags menu
- [4] Serv Byp (Service Bypass) menu
- [5] Versions menu
- [6] Cloud menu
- [1] Program menu
- Specifications
- Appendix
- Back Page
Keypad Installer menu
In addition to using RPS to configure and diagnose a system, you can also perform
programming and diagnostics using a keypad. Programming and diagnostics options appear on
the keypad when you access the Main menu (Installer) option, which includes the Installer
menu. The Main menu (Installer) option becomes available during normal control panel
operation only when you enter your installer passcode and press [ENTER]. The default
Installer passcode is 1-2-3.
The tools within the Installer menu are:
– Program menu. Program several parameters to make your system operational, including
phone number and format, enhanced communication options, RPS parameters, users,
points, and keypad parameters. Refer to [1] Program menu, page 109 for more detailed
information on each programming option, and to RPS Help or the control panel's Program
Entry Guide.
– Wireless menu. Add, replace, remove, and diagnose points and repeaters. Refer to [2]
Wireless menu, page 136.
– Diags menu. Diagnose points, repeaters, cellular service, IP cameras, and Cloud. Refer to
[3] Diags menu, page 141.
– Service Bypass menu. View whether points are removed from service. Refer to [4] Serv
Byp (Service Bypass) menu, page 144.
– Versions menu. View the version information for the control panel, encryption, and more.
Refer to [5] Versions menu, page 144.
– Cloud menu. Enable Cloud connectivity for the control panel. Refer to [6] Cloud menu,
page 146.
Installer keypads and SERVICE MODE
The Installer menu is also available from the Service menu when in SERVICE MODE. The
Service menu is a subset of the Main menu (Installer) option. You can use Service mode at any
keypad, but the feature is most useful when you want to directly connect an Installer keypad
to the control panel for keypad programming at the control panel. Set the Installer keypad to
address 0, and then connect it to the control panel.
Use the control panel RESET button to enter SERVICE MODE. The rate of flashing of the
Heartbeat LED increases while in SERVICE MODE.