Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Certifications, approvals, listings, and safety
- Introduction
- System overview
- Installation checklist
- Control panel installation
- Power supply
- Telephone communications
- IP communications
- Keypads, keyswitches, keyfobs and transmitters
- Keypads
- B915 Basic Keypad
- B920 Two-line Alphanumeric Keypad
- B921C Two-line Capacitive Keypad with Inputs
- B930 ATM Style Alphanumeric Keypad
- B942 Touch Screen Keypad
- Shortcuts and custom functions
- Address settings
- Supervision
- Installation and control panel wiring (keypads)
- Sensor loops overview and wiring (B921C/B942/B942W only)
- Output wiring (B942/B942W only)
- Troubleshooting
- Keyswitches
- RADION keyfobs and Inovonics pendant transmitters
- Keypads
- On-board outputs
- Off-board outputs
- On-board points
- Off-board points
- Wireless modules
- Access control
- Program and test the control panel
- Control panel board overview
- System wiring diagrams
- Approved applications
- Keypad Installer menu
- [1] Program menu
- [1] Reporting > [1] Phone menu parameters
- [1] Reporting > [2] Network menu parameters
- [1] Reporting > [3] Routing menu parameters
- [1] Reporting > [4] Personal Note menu parameters
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [1] Module Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [2] Address Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [3] DNS Parameters menu
- [2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in module)
- [3] RPS > [1] RPS Passcode menu parameters
- [3] RPS > [2] RPS Phone Number menu parameters
- [3] RPS > [3] RPS IP Address menu parameters
- [3] RPS > [4] RPS Port Number menu parameters
- [4] Area Options menu parameters
- [5] Keypad menu parameters
- [6] Users menu parameters
- [7] Points menu parameters
- [8] Disable Programming menu
- [2] Wireless menu
- [1] RF Point Menu> [1] Enroll Point RFID
- [1] RF Point Menu> [2] Replace Point RFID
- [1] RF Point Menu> [3] Remove Point RFID
- [2] RF Repeater Menu > [1] Add Repeater
- [2] RF Repeater Menu > [2] Replace Repeater
- [2] RF Repeater Menu > [3] Remove Repeater
- [3] RF Diagnostic Menu > [1] RF Points
- [3] RF Diagnostic Menu > [2] RF Repeater Menu
- [3] Diags menu
- [4] Serv Byp (Service Bypass) menu
- [5] Versions menu
- [6] Cloud menu
- [1] Program menu
- Specifications
- Appendix
- Back Page
2. Go to [1] Program > [1] Reporting > [4] Personal Note. The keypad shows the phone
number or email address of the selected destination.
3. Use /[PREV] or /[NEXT] to scroll though the list of destinations and go to the
destination you want to program.
4. Press [Edit] to edit the phone number or email address.
5. Delete existing characters, if necessary, and then enter the new characters.
6. Press [Save] to save the phone number or email address.
7. When the keypad shows Parameter Saved, escape from the menu.
[2] Network > [1] Ethernet > (choose the bus module or on-board) > [1]
Module Parameters menu
You can use DCHP/AutoIP or UPnP for Ethernet communication with the on-board Ethernet or
a B426. In this menu, you can enable and disable these protocols.
Default Module settings
DHCP/AutoIP Enable Yes Yes/No
UPnP Enable Yes Yes/No
IPv4 Address 0.0.0.0 _______________________________
IPv4 Subnet Mask 255.255.255.255 _______________________________
Default Gateway 0.0.0.0 _______________________________
HTTP Port Number 80 _______________________________
IPv4 Server Address 0.0.0.0 _______________________________
IPv6 Server Address 0.0.0.0 _______________________________
Module Hostname Blank _______________________________
DHCP/AutoIP Enable
B91x/B92x keypads configuration of DHCP/AutoIP Enable
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[1] Module Parameters > [1] DHCP. The keypad shows the DHCP/AutoIP current
configuration.
3. Press [ENTER] to edit the DHCP/AutoIP Enable configuration for the module.
4. Use [PREV] or [NEXT] to toggle between Yes and No.
5. Press [ENTER] while viewing the desired option to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads configuration of DHCP/AutoIP Enable
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[1] Module Parameters > [1] DHCP. The keypad shows the DHCP/AutoIP current
configuration.
3. Press [Yes] or [No] – whichever is available – to change the programming.
4. Press [Save] to save the programming.
5. When the keypad shows Parameter Saved, escape from the menu.
UPnP Enable
20.1.5
Control Panel Keypad Installer menu | en 115
Bosch Security Systems, Inc. Installation and System Reference Guide 2016.05 | 14 | F.01U.287.180