Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Certifications, approvals, listings, and safety
- Introduction
- System overview
- Installation checklist
- Control panel installation
- Power supply
- Telephone communications
- IP communications
- Keypads, keyswitches, keyfobs and transmitters
- Keypads
- B915 Basic Keypad
- B920 Two-line Alphanumeric Keypad
- B921C Two-line Capacitive Keypad with Inputs
- B930 ATM Style Alphanumeric Keypad
- B942 Touch Screen Keypad
- Shortcuts and custom functions
- Address settings
- Supervision
- Installation and control panel wiring (keypads)
- Sensor loops overview and wiring (B921C/B942/B942W only)
- Output wiring (B942/B942W only)
- Troubleshooting
- Keyswitches
- RADION keyfobs and Inovonics pendant transmitters
- Keypads
- On-board outputs
- Off-board outputs
- On-board points
- Off-board points
- Wireless modules
- Access control
- Program and test the control panel
- Control panel board overview
- System wiring diagrams
- Approved applications
- Keypad Installer menu
- [1] Program menu
- [1] Reporting > [1] Phone menu parameters
- [1] Reporting > [2] Network menu parameters
- [1] Reporting > [3] Routing menu parameters
- [1] Reporting > [4] Personal Note menu parameters
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [1] Module Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [2] Address Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [3] DNS Parameters menu
- [2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in module)
- [3] RPS > [1] RPS Passcode menu parameters
- [3] RPS > [2] RPS Phone Number menu parameters
- [3] RPS > [3] RPS IP Address menu parameters
- [3] RPS > [4] RPS Port Number menu parameters
- [4] Area Options menu parameters
- [5] Keypad menu parameters
- [6] Users menu parameters
- [7] Points menu parameters
- [8] Disable Programming menu
- [2] Wireless menu
- [1] RF Point Menu> [1] Enroll Point RFID
- [1] RF Point Menu> [2] Replace Point RFID
- [1] RF Point Menu> [3] Remove Point RFID
- [2] RF Repeater Menu > [1] Add Repeater
- [2] RF Repeater Menu > [2] Replace Repeater
- [2] RF Repeater Menu > [3] Remove Repeater
- [3] RF Diagnostic Menu > [1] RF Points
- [3] RF Diagnostic Menu > [2] RF Repeater Menu
- [3] Diags menu
- [4] Serv Byp (Service Bypass) menu
- [5] Versions menu
- [6] Cloud menu
- [1] Program menu
- Specifications
- Appendix
- Back Page
B91x/B92x keypads configuration of Add Repeater
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [2] Wireless > [2] RF Repeater Menu > [1] Add Repeater. The keypad lists any
repeaters.
3. Use [PREV] or [NEXT] to scroll though the list, and go to the repeater number for which
you want to add a repeater, or simply enter the repeater number.
4. Press [ENTER] to add the device. The keypad instructs you to reset the device.
5. Initiate discovery on a RADION device per the device instructions, or press the RESET
button on an Inovonics device.
6. When the keypad shows Repeater Added, escape from the menu.
B93x/B94x keypads configuration of Add Repeater
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [2] Program > [2] RF Repeater Menu > [1] Add Repeater. The keypad lists any
repeaters.
3. Use
/[PREV] or /[NEXT] to scroll though the list, and go to the repeater number for
which you want to add a repeater, or simply enter the repeater number.
4. Press [ENTER] to add the device to the number. The keypad instructs you to reset the
device.
5. Initiate discovery on a RADION device per the device instructions, or press the RESET
button on an Inovonics device.
6. When the keypad shows Repeater Added, escape from the menu.
[2] RF Repeater Menu > [2] Replace Repeater
In this menu, you can replace Repeater points.
Replace Repeater
B91x/B92x keypads use of Replace Repeater
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [2] Wireless > [2] RF Repeater Menu > [2] Replace Repeater. The keypad lists any
existing repeaters.
3. Use [PREV] or [NEXT] to scroll though the list of repeaters, and go to the repeater you
want to replace, or simply enter the repeater number.
4. Press [ENTER] to replace the device. The keypad instructs you to reset the new device.
5. Initiate discovery on a RADION device per the device instructions, or press the RESET
button on an Inovonics device.
6. When the keypad shows Repeater Replaced, escape from the menu.
B93x/B94x keypads use of Replace Repeater
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [2] Program > [2] RF Repeater Menu > [2] Replace Repeater. The keypad lists any
existing repeaters.
3. Use
/[PREV] or /[NEXT] to scroll though the list of repeaters, and go to the repeater
you want to replace, or simply enter the repeater number.
4. Press [ENTER] to replace the device. The keypad instructs you to reset the new device.
5. Initiate discovery on a RADION device per the device instructions, or press the RESET
button on an Inovonics device.
6. When the keypad shows Repeater Replaced, escape from the menu.
20.2.5
138 en | Keypad Installer menu Control Panel
2016.05 | 14 | F.01U.287.180 Installation and System Reference Guide Bosch Security Systems, Inc.