Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Certifications, approvals, listings, and safety
- Introduction
- System overview
- Installation checklist
- Control panel installation
- Power supply
- Telephone communications
- IP communications
- Keypads, keyswitches, keyfobs and transmitters
- Keypads
- B915 Basic Keypad
- B920 Two-line Alphanumeric Keypad
- B921C Two-line Capacitive Keypad with Inputs
- B930 ATM Style Alphanumeric Keypad
- B942 Touch Screen Keypad
- Shortcuts and custom functions
- Address settings
- Supervision
- Installation and control panel wiring (keypads)
- Sensor loops overview and wiring (B921C/B942/B942W only)
- Output wiring (B942/B942W only)
- Troubleshooting
- Keyswitches
- RADION keyfobs and Inovonics pendant transmitters
- Keypads
- On-board outputs
- Off-board outputs
- On-board points
- Off-board points
- Wireless modules
- Access control
- Program and test the control panel
- Control panel board overview
- System wiring diagrams
- Approved applications
- Keypad Installer menu
- [1] Program menu
- [1] Reporting > [1] Phone menu parameters
- [1] Reporting > [2] Network menu parameters
- [1] Reporting > [3] Routing menu parameters
- [1] Reporting > [4] Personal Note menu parameters
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [1] Module Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [2] Address Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [3] DNS Parameters menu
- [2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in module)
- [3] RPS > [1] RPS Passcode menu parameters
- [3] RPS > [2] RPS Phone Number menu parameters
- [3] RPS > [3] RPS IP Address menu parameters
- [3] RPS > [4] RPS Port Number menu parameters
- [4] Area Options menu parameters
- [5] Keypad menu parameters
- [6] Users menu parameters
- [7] Points menu parameters
- [8] Disable Programming menu
- [2] Wireless menu
- [1] RF Point Menu> [1] Enroll Point RFID
- [1] RF Point Menu> [2] Replace Point RFID
- [1] RF Point Menu> [3] Remove Point RFID
- [2] RF Repeater Menu > [1] Add Repeater
- [2] RF Repeater Menu > [2] Replace Repeater
- [2] RF Repeater Menu > [3] Remove Repeater
- [3] RF Diagnostic Menu > [1] RF Points
- [3] RF Diagnostic Menu > [2] RF Repeater Menu
- [3] Diags menu
- [4] Serv Byp (Service Bypass) menu
- [5] Versions menu
- [6] Cloud menu
- [1] Program menu
- Specifications
- Appendix
- Back Page
[6] Cloud menu
Use the Cloud menu to enable or disable the Cloud capability in the control panel.
Cloud (In the Installer menu)
B91x/B92x keypads configuration of Cloud
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [6] Cloud. The keypad shows the current status; disabled, enabled on Ethernet,
enabled on cellular, or enabled on both Ethernet and cellular.
3. Press [ENTER] to change the status, or press [ESC] without making a change. Use [NEXT]
to scroll through the list of available options and press [ENTER] to accept the choice on
the display. To use the Cloud, enable it on Ethernet or Cellular or both.
4. Upon changing the setting, the keypad shows Parameter Saved, and then closes the menu.
B93x/B94x keypads use of Enable Status
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [6] Cloud. The keypad shows the current status; disabled, enabled on Ethernet,
enabled on cellular, or enabled on both Ethernet and cellular.
3. Press [Edit] to change the status, or press [ESC] without making a change. Use
/
[NEXT] to scroll through the list of available options and press Save to accept the choice
on the display To use the Cloud, enable it on either Ethernet or Cellular or both.
4. Upon changing the setting, the keypad shows Parameter Saved, and then closes the menu.
20.6
146 en | Keypad Installer menu Control Panel
2016.05 | 14 | F.01U.287.180 Installation and System Reference Guide Bosch Security Systems, Inc.