Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Certifications, approvals, listings, and safety
- Introduction
- System overview
- Installation checklist
- Control panel installation
- Power supply
- Telephone communications
- IP communications
- Keypads, keyswitches, keyfobs and transmitters
- Keypads
- B915 Basic Keypad
- B920 Two-line Alphanumeric Keypad
- B921C Two-line Capacitive Keypad with Inputs
- B930 ATM Style Alphanumeric Keypad
- B942 Touch Screen Keypad
- Shortcuts and custom functions
- Address settings
- Supervision
- Installation and control panel wiring (keypads)
- Sensor loops overview and wiring (B921C/B942/B942W only)
- Output wiring (B942/B942W only)
- Troubleshooting
- Keyswitches
- RADION keyfobs and Inovonics pendant transmitters
- Keypads
- On-board outputs
- Off-board outputs
- On-board points
- Off-board points
- Wireless modules
- Access control
- Program and test the control panel
- Control panel board overview
- System wiring diagrams
- Approved applications
- Keypad Installer menu
- [1] Program menu
- [1] Reporting > [1] Phone menu parameters
- [1] Reporting > [2] Network menu parameters
- [1] Reporting > [3] Routing menu parameters
- [1] Reporting > [4] Personal Note menu parameters
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [1] Module Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [2] Address Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [3] DNS Parameters menu
- [2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in module)
- [3] RPS > [1] RPS Passcode menu parameters
- [3] RPS > [2] RPS Phone Number menu parameters
- [3] RPS > [3] RPS IP Address menu parameters
- [3] RPS > [4] RPS Port Number menu parameters
- [4] Area Options menu parameters
- [5] Keypad menu parameters
- [6] Users menu parameters
- [7] Points menu parameters
- [8] Disable Programming menu
- [2] Wireless menu
- [1] RF Point Menu> [1] Enroll Point RFID
- [1] RF Point Menu> [2] Replace Point RFID
- [1] RF Point Menu> [3] Remove Point RFID
- [2] RF Repeater Menu > [1] Add Repeater
- [2] RF Repeater Menu > [2] Replace Repeater
- [2] RF Repeater Menu > [3] Remove Repeater
- [3] RF Diagnostic Menu > [1] RF Points
- [3] RF Diagnostic Menu > [2] RF Repeater Menu
- [3] Diags menu
- [4] Serv Byp (Service Bypass) menu
- [5] Versions menu
- [6] Cloud menu
- [1] Program menu
- Specifications
- Appendix
- Back Page
Panel event Modem4 code
D6500 mode
Modem4 code
Bosch SIA mode
Contact ID event Contact ID code
Duplicate SDI2 device
Restore
RsssD NpiddddER System Peripheral Trouble
Restore
3 330 aa iii
Duress Diiii Nriaa/idiiiiHA Duress 1 121 aa uuu
Equipment Fail TsD29 NpiddddIA System Peripheral Trouble 1 330 00
1
zzz
Equipment Restore RsD29 NpiddddIR System Peripheral Trouble
Restore
3 330 00
1
zzz
Event Log Overflow AsD01 NJO Event Log Overflow 1 624 00 000
Event Log Threshold has
been reached
TsD01 NJL Event Log 90% Full 1 623 00 000
Extend Close Time by Area TsD26 Nriaa/idiiii/
tihhmmCE
Auto-arm Time Extended 1 464 aa uuu
Extra Point Tpppp NriaaXEpppp Maintenance Alert 1 393 aa ppp
Fail To Close by Area TsssE NriaCl Failed to Close 1 454 aa 000
Fail to Open by Area TsssE NriaOl Failed to Open 1 453 aa 000
Fire Alarm Fspppp NriaaFApppp Fire 1 110 aa ppp
Fire Cancel \iiii Nriaa/idiiiiFC Cancel 1 406 aa uuu
Fire Drill Start TsssF Nriaa/idiiiiFL Fire Test Start 1 604 aa iii
Fire Drill End RsssF Nriaa/idiiiiNF Fire Test End 3 604 aa iii
Fire Missing Mpppp NriaaFYpppp Fire Trouble 1 373 aa ppp
Fire Restoral from Alarm Hspppp NriaaFHpppp Fire Alarm Restore 3 110 aa ppp
Fire Restoral from Trouble Hspppp NriaaFJpppp Fire Trouble Restore 3 373 aa ppp
Fire Supervision Espppp NriaaFSpppp Fire Supervisory 1 200 aa ppp
Fire Supervision from Restore Espppp NriaaFVpppp Fire Supervisory Restore 3 200 aa ppp
Fire Trouble Gspppp NriaaFTpppp Fire Trouble 1 373 aa ppp
Fire Walk Test End RsssF Nriaa/idiiiiFK Fire Test End 3 604 aa uuu
Fire Walk Test Start TsssF Nriaa/idiiiiFl Fire Test Start 1 604 aa uuu
Forced Armed PartOn Delay Csiiii Nriaa/idiiiiNF Partial Arm 3 456 aa uuu
Forced Armed PartOn Instant Csiiii Nriaa/idiiiiNF Partial Arm 3 456 aa uuu
Forced Close Early by Area Csiiii Nriaa/idiiiiCF Early O/C 3 451 aa uuu
Forced Close Late by Area Csiiii Nriaa/idiiiiCF Late O/C 3 452 aa uuu
Forced Closing by Area Csiiii Nriaa/idiiiiCF O/C by User 3 401 aa uuu
Forced Point Tspppp NriaaXWpppp Zone/Sensor Bypass 1 570 aa ppp
Gas Alarm Apppp NriaaGApppp Gas Detected 1 151 aa ppp
Control Panel Appendix | en 155