Installation Manual

Table Of Contents
Panel event Modem4 code
D6500 mode
Modem4 code
Bosch SIA mode
Contact ID event Contact ID code
Missing Supervision MTpppp NriaaBZpppp Loss of Supervision –RPM 1 382 aa ppp
Missing Trouble Vpppp NriaaUYpppp Loss of Supervision - RPM 1 382 aa ppp
Network Cable Connected NsD43 NpiddddNR010 System Peripheral Trouble
Restore
3 330 00 zzz
Network Cable Disconnected NsD42 NpiddddNT010 System Peripheral Trouble 1 330 00 zzz
Non-Fire Cancel Alarm \siiii Nriaa/idiiiiBC Cancel 1 406 aa uuu
Normal start-up of the
control panel
NsD14 NRR System Reset 1 305 00 000
Opening by Account OSiiii NidiiiiOP O/C by account 1 401 00 uuu
Opening by Area Osiiii Nriaa/idiiiiOP O/C by user 1 401 aa uuu
Opening Early by Area Osiiii Nriaa/idiiiiOK Early O/C 1 451 aa uuu
Opening Late by Area Osiiii Nriaa/idiiiiOJ Late O/C 1 452 aa uuu
Parameters changed NsD02 NYG Panel Programming
Changed
1 306 00 000
Personal Notification
Communication Trouble
TsB01 NpiddddYS Communication Trouble 1 350 0 zzz
Personal Notification
Communication Trouble
Restore
NsB01 NpiddddYK Communication Trouble
Restore
3 350 0 zzz
Phone Line Missing 1 TsssB NLT1 Telco 1 Fault 1 351 00 000
Phone Line Restored 1 RsssB NLR1 Telco 1 Fault Restore 3 351 00 000
Popex Bus Fault TsssD NYI PS Over Current 1 312 00 ZZZ
Popex Bus Fault Restore RsssD NYJ PS Over Current Restore 3 312 00 ZZZ
Popex Invalid Popit TsssD NYI PS Over Current 1 312 00 ZZZ
Popex Invalid Popit Restore RsssD NYJ PS Over Current Restore 3 312 00 ZZZ
Popex Low Voltage TsssD NYI PS Over Current 1 312 00 ZZZ
Popex Low Voltage Restore RsssD NYJ PS Over Current Restore 3 312 00 ZZZ
Programming Started TsssF NiduuuuTS System Shutdown 1 308 00 iii
Programming Finished RsssF NiduuuuTE System Shutdown Restore 3 308 00 iii
RAM Fail with RPS TsF02 NRA Unsuccessful access 1 413 00 000
Re-Boot NsD14t NRR System Reset 1 305 00 000
Relay Reset by Sked NsD20 NaikkkROrrrr Sounder/Relay Reset 3 320 00 000
Relay Reset by User NsD18 NidiiiiROrrrr Sounder/Relay Reset 3 320 00 000
Relay Set by Sked NsD19 NaikkkRCrrrr Sounder/Relay Set 1 320 00 000
Control Panel Appendix | en 157
Bosch Security Systems, Inc. Installation and System Reference Guide 2016.05 | 14 | F.01U.287.180