Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Certifications, approvals, listings, and safety
- Introduction
- System overview
- Installation checklist
- Control panel installation
- Power supply
- Telephone communications
- IP communications
- Keypads, keyswitches, keyfobs and transmitters
- Keypads
- B915 Basic Keypad
- B920 Two-line Alphanumeric Keypad
- B921C Two-line Capacitive Keypad with Inputs
- B930 ATM Style Alphanumeric Keypad
- B942 Touch Screen Keypad
- Shortcuts and custom functions
- Address settings
- Supervision
- Installation and control panel wiring (keypads)
- Sensor loops overview and wiring (B921C/B942/B942W only)
- Output wiring (B942/B942W only)
- Troubleshooting
- Keyswitches
- RADION keyfobs and Inovonics pendant transmitters
- Keypads
- On-board outputs
- Off-board outputs
- On-board points
- Off-board points
- Wireless modules
- Access control
- Program and test the control panel
- Control panel board overview
- System wiring diagrams
- Approved applications
- Keypad Installer menu
- [1] Program menu
- [1] Reporting > [1] Phone menu parameters
- [1] Reporting > [2] Network menu parameters
- [1] Reporting > [3] Routing menu parameters
- [1] Reporting > [4] Personal Note menu parameters
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [1] Module Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [2] Address Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [3] DNS Parameters menu
- [2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in module)
- [3] RPS > [1] RPS Passcode menu parameters
- [3] RPS > [2] RPS Phone Number menu parameters
- [3] RPS > [3] RPS IP Address menu parameters
- [3] RPS > [4] RPS Port Number menu parameters
- [4] Area Options menu parameters
- [5] Keypad menu parameters
- [6] Users menu parameters
- [7] Points menu parameters
- [8] Disable Programming menu
- [2] Wireless menu
- [1] RF Point Menu> [1] Enroll Point RFID
- [1] RF Point Menu> [2] Replace Point RFID
- [1] RF Point Menu> [3] Remove Point RFID
- [2] RF Repeater Menu > [1] Add Repeater
- [2] RF Repeater Menu > [2] Replace Repeater
- [2] RF Repeater Menu > [3] Remove Repeater
- [3] RF Diagnostic Menu > [1] RF Points
- [3] RF Diagnostic Menu > [2] RF Repeater Menu
- [3] Diags menu
- [4] Serv Byp (Service Bypass) menu
- [5] Versions menu
- [6] Cloud menu
- [1] Program menu
- Specifications
- Appendix
- Back Page
Panel event Modem4 code
D6500 mode
Modem4 code
Bosch SIA mode
Contact ID event Contact ID code
SDI Device Missing Battery
Restore
RsssDt NpiddddEVbb Exp. Module Low Batt.
Restore
3 338 00
1
zzz
SDI Device Missing Restore RsssDt NpiddddEN Exp. Module Failure
Restore
3 333 00
1
zzz
SDI Device Over Current TsssD NYI PS Over Current 1 312 00
1
zzz
SDI Device Over Current
Restore
RsssD NYJ PS Over Current Restore 3 312 00
1
zzz
SDI Device Tamper TsssD NES Exp. Module Tamper 1 341 00
1
zzz
SDI Device Tamper Restore TsssD NES Exp. Module Tamper
Restore
3 341 00
1
zzz
SDI Device Trouble TsssD NET System Peripheral Trouble 1 330 00
1
zzz
SDI Device Trouble Restore RsssD NER System Peripheral Trouble
Restore
3 330 00
1
zzz
SDI2 device is missing TsssD NpiddddEM Expansion Module Failure 1 333 00 000
SDI2 device is restored from
missing
RsssD NpiddddEN Expansion Module Failure 3 333 00 000
SDI2 Open Trouble TsssD NpiiddddET Expansion Module Failure 1 333 00
1
zzz
SDI2 Open Trouble Restoral RsssD NpiddddER Expansion Module Failure
Restore
3 333 00
1
zzz
Sensor Reset NsD27 Nriaa/idiiiiXlrrrr Sounder/Relay Reset 3 320 00 000
Service Bypass Npppp NriaaUBpppp Service Request 1 616 aa ppp
Service Bypass Cancel RBpppp NriaaUUpppp Service Request Restore 3 616 aa ppp
Service Smoke Detector Tpppp NriaaASpppp Maintenance Alert 1 393 aa ppp
Service Smoke Detector
Restore
Rpppp NriaaANpppp Maintenance Alert Restore 3 393 aa ppp
Service Walk Test End RsssF NidiiiiTE Service On/Off Premises 3 466 aa uuu
Service Walk Test Start TsssF Nriaa/idiiiiTS Service On/Off Premises 1 466 aa uuu
Sked Changed – No User
Identified
NsD06 NaikkkJS Schedule Change 1 630 00 000
Sked Changed by User NsD06 Nidiiii/aikkkJS Schedule Change 1 630 00 000
Sked has Executed NsD25 NaikkkJR Local Only Local Only
Status: Burg Alarm SApppp OriaaBApppp NA NA
Status: Burg Supervisory STpppp OriaaBSpppp NA NA
Status: Burg Trouble STpppp OriaaBTpppp NA NA
Status: Close by Area SCssss OriaCL NA NA
Control Panel Appendix | en 159
Bosch Security Systems, Inc. Installation and System Reference Guide 2016.05 | 14 | F.01U.287.180