Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Certifications, approvals, listings, and safety
- Introduction
- System overview
- Installation checklist
- Control panel installation
- Power supply
- Telephone communications
- IP communications
- Keypads, keyswitches, keyfobs and transmitters
- Keypads
- B915 Basic Keypad
- B920 Two-line Alphanumeric Keypad
- B921C Two-line Capacitive Keypad with Inputs
- B930 ATM Style Alphanumeric Keypad
- B942 Touch Screen Keypad
- Shortcuts and custom functions
- Address settings
- Supervision
- Installation and control panel wiring (keypads)
- Sensor loops overview and wiring (B921C/B942/B942W only)
- Output wiring (B942/B942W only)
- Troubleshooting
- Keyswitches
- RADION keyfobs and Inovonics pendant transmitters
- Keypads
- On-board outputs
- Off-board outputs
- On-board points
- Off-board points
- Wireless modules
- Access control
- Program and test the control panel
- Control panel board overview
- System wiring diagrams
- Approved applications
- Keypad Installer menu
- [1] Program menu
- [1] Reporting > [1] Phone menu parameters
- [1] Reporting > [2] Network menu parameters
- [1] Reporting > [3] Routing menu parameters
- [1] Reporting > [4] Personal Note menu parameters
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [1] Module Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [2] Address Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [3] DNS Parameters menu
- [2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in module)
- [3] RPS > [1] RPS Passcode menu parameters
- [3] RPS > [2] RPS Phone Number menu parameters
- [3] RPS > [3] RPS IP Address menu parameters
- [3] RPS > [4] RPS Port Number menu parameters
- [4] Area Options menu parameters
- [5] Keypad menu parameters
- [6] Users menu parameters
- [7] Points menu parameters
- [8] Disable Programming menu
- [2] Wireless menu
- [1] RF Point Menu> [1] Enroll Point RFID
- [1] RF Point Menu> [2] Replace Point RFID
- [1] RF Point Menu> [3] Remove Point RFID
- [2] RF Repeater Menu > [1] Add Repeater
- [2] RF Repeater Menu > [2] Replace Repeater
- [2] RF Repeater Menu > [3] Remove Repeater
- [3] RF Diagnostic Menu > [1] RF Points
- [3] RF Diagnostic Menu > [2] RF Repeater Menu
- [3] Diags menu
- [4] Serv Byp (Service Bypass) menu
- [5] Versions menu
- [6] Cloud menu
- [1] Program menu
- Specifications
- Appendix
- Back Page
SDI2 address information
Notice!
All point numbers, user ID’s, output numbers, and device identifier numbers are formatted as
4-digit numbers (right justified with zeros) when transmitted from the control panel in
Modem4 format.
SDI2 address zzz data values Description
01-08 001-008 SDI2 Keypad 1 through 8
01-04 201-204 SDI2 Octo-input Modules 1 through 4
01-05 301-305 SDI2 Octo-output Modules 1 through 5
1 801 SDI2 Premises RF Module
N/A 851-858 SDI2 RF Repeater 1 through 8
1 401 SDI2 Network Module 1
01-04 501-504 SDI2 Power Supply Module 1 through 8
01-08 901-916 SDI2 Keypads 1 through 16
1 411, 421, 431, 441 Routes 1 through 4 on SDI2 Network Module 1
99 499 DNS lookup error of RPS hostname
N/A 100 On-board Control Panel Enclosure Tamper
N/A 400 On-board Ethernet
N/A 408-409 On-board Plug-in Modules 1 through 2
Device numbers (zzz, dddd)
Bus Keypad display # Reporting number Description
OnBrd 100 100 Control Panel Enclosure
OnBrd 400 400 On-board Ethernet module
OnBrd 408 408 Plug-in Module
SDI2 2 – 25 201 – 224 Octo-Input Modules 1 through 24
SDI2 66 – 77 301 – 312 Octo-Output Modules 1 through 12
SDI2 151 801 Premises RF Module
SDI2 161 – 168 851 – 858 RF Repeaters 1 through 8
SDI2 173 401 Network Module 1
SDI2 174 402 Network Module 2
SDI2 176 - 183 501 – 508 Power Supply Modules 1 through 8
SDI2 200 - 216 901 – 916 Keypads 1 through 16
22.2.2
22.2.3
Control Panel Appendix | en 161
Bosch Security Systems, Inc. Installation and System Reference Guide 2016.05 | 14 | F.01U.287.180