Installation Manual

Table Of Contents
Flash pattern Function
On Steady
Trouble state. Indicates a trouble condition
exists. Examine the other LEDs to determine
the trouble condition.
Off
LED trouble state. Indicates the module is
not powered up, or there is a failure in the
module. Check for proper installation.
Table 8.8: Heartbeat LED descriptions
Flash pattern
Function
RX (Receive)
Flashing
Occurs every time a packet is received on-air.
TX (Transmit)
Flashing
Occurs every time a packet is transmitted on-
air.
Table 8.9: RX and TX LED descriptions
Refer to the module’s Installation and Operation Guide for more information on the LEDs and
troubleshooting.
Compatible receivers for IP communication
When the control panel is configured to report in Modem4 format, the Conettix central station
receiver/gateway and the D6200 Programming/Administration Software may require an
update. Requirements are shown in the Modem4 requirements table below.
Receiver/Gateway CPU version D6200 version
Conettix D6600 Communications Receiver/Gateway
(with D6641 line cards installed only)
01.10.00 2.10
Conettix D6100IPv6 Communications Receiver/Gateway 01.10.00 2.10
Conettix D6100i Communications Receiver/Gateway 01.10.00 2.10
When the control panel is configured to report in the Contact ID reporting format, the
Conettix central station receiver/gateway and the D6200 Programming/Administration
Software may require an update as shown in the Contact ID requirements table below.
ContactID reporting format requirements
Receiver/Gateway
CPU version D6200 version
Conettix D6600 Communications Receiver/Gateway
(with D6641 line cards installed only)
01.03.02 1.35
Conettix D6100IPv6 Communications Receiver/Gateway 61.10.00 2.10
Conettix D6100i Communications Receiver/Gateway 61.04.00 1.35
8.5
52 en | IP communications Control Panel