Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Certifications, approvals, listings, and safety
- Introduction
- System overview
- Installation checklist
- Control panel installation
- Power supply
- Telephone communications
- IP communications
- Keypads, keyswitches, keyfobs and transmitters
- Keypads
- B915 Basic Keypad
- B920 Two-line Alphanumeric Keypad
- B921C Two-line Capacitive Keypad with Inputs
- B930 ATM Style Alphanumeric Keypad
- B942 Touch Screen Keypad
- Shortcuts and custom functions
- Address settings
- Supervision
- Installation and control panel wiring (keypads)
- Sensor loops overview and wiring (B921C/B942/B942W only)
- Output wiring (B942/B942W only)
- Troubleshooting
- Keyswitches
- RADION keyfobs and Inovonics pendant transmitters
- Keypads
- On-board outputs
- Off-board outputs
- On-board points
- Off-board points
- Wireless modules
- Access control
- Program and test the control panel
- Control panel board overview
- System wiring diagrams
- Approved applications
- Keypad Installer menu
- [1] Program menu
- [1] Reporting > [1] Phone menu parameters
- [1] Reporting > [2] Network menu parameters
- [1] Reporting > [3] Routing menu parameters
- [1] Reporting > [4] Personal Note menu parameters
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [1] Module Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [2] Address Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [3] DNS Parameters menu
- [2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in module)
- [3] RPS > [1] RPS Passcode menu parameters
- [3] RPS > [2] RPS Phone Number menu parameters
- [3] RPS > [3] RPS IP Address menu parameters
- [3] RPS > [4] RPS Port Number menu parameters
- [4] Area Options menu parameters
- [5] Keypad menu parameters
- [6] Users menu parameters
- [7] Points menu parameters
- [8] Disable Programming menu
- [2] Wireless menu
- [1] RF Point Menu> [1] Enroll Point RFID
- [1] RF Point Menu> [2] Replace Point RFID
- [1] RF Point Menu> [3] Remove Point RFID
- [2] RF Repeater Menu > [1] Add Repeater
- [2] RF Repeater Menu > [2] Replace Repeater
- [2] RF Repeater Menu > [3] Remove Repeater
- [3] RF Diagnostic Menu > [1] RF Points
- [3] RF Diagnostic Menu > [2] RF Repeater Menu
- [3] Diags menu
- [4] Serv Byp (Service Bypass) menu
- [5] Versions menu
- [6] Cloud menu
- [1] Program menu
- Specifications
- Appendix
- Back Page
16.2 Perform walk tests 77
16.2.1 Fire walk test 77
16.2.2 Intrusion walk test 78
16.2.3 Service walk test 78
16.2.4 Invisible walk test 79
17
Control panel board overview 80
18
System wiring diagrams 82
18.1 System wiring overview 82
18.2 Battery lead supervision wiring 84
18.3 2-wire smoke wiring (B201) 85
18.4 2-wire smoke wiring (D125B) 86
18.5 Notification appliance circuit wiring 86
18.6 SDI2 devices general system wiring 88
18.6.1 SDI2 bus wiring recommendations 88
18.7 Wiring label 91
19
Approved applications 92
19.1 Optional compatible equipment 92
19.1.1 Burglar applications 92
19.1.2 Bank safe and vault applications 92
19.1.3 Fire applications 95
19.1.4 Enclosures 96
19.2 Combination fire and intrusion alarm systems 97
19.3 Compatible UL listed components 97
19.4 Standby battery requirements and calculations 99
19.4.1 Household Fire Warning equipment 101
19.5 UL 365 - Police Station Connected Burglar Alarm Units and Systems 101
19.6 UL 636 - Holdup Alarm Units and System 102
19.7 ULC 102
20
Keypad Installer menu 103
20.1 [1] Program menu 109
20.1.1 [1] Reporting > [1] Phone menu parameters 109
20.1.2 [1] Reporting > [2] Network menu parameters 110
20.1.3 [1] Reporting > [3] Routing menu parameters 112
20.1.4 [1] Reporting > [4] Personal Note menu parameters 114
20.1.5 [2] Network > [1] Ethernet > (choose the bus module or on-board) > [1] Module
Parameters menu
115
20.1.6 [2] Network > [1] Ethernet > (choose the bus module or on-board) > [2] Address
Parameters menu
116
20.1.7 [2] Network > [1] Ethernet > (choose the bus module or on-board) > [3] DNS
Parameters menu
118
20.1.8 [2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in module) 119
20.1.9 [3] RPS > [1] RPS Passcode menu parameters 121
20.1.10 [3] RPS > [2] RPS Phone Number menu parameters 122
20.1.11 [3] RPS > [3] RPS IP Address menu parameters 122
20.1.12 [3] RPS > [4] RPS Port Number menu parameters 123
20.1.13 [4] Area Options menu parameters 123
20.1.14 [5] Keypad menu parameters 124
20.1.15 [6] Users menu parameters 125
20.1.16 [7] Points menu parameters 126
6 en | Table of Contents Control Panel
2016.05 | 14 | F.01U.287.180 Installation and System Reference Guide Bosch Security Systems, Inc.