Installation Manual

Table Of Contents
1 kW
8
1
4
5
6
7
2
3
2
3
2
3
9
10
Figure 12.1: On-board point sensor loop wiring, single EOL resistor
Callout Description
1 100 Ω maximum
2 Point input terminal
3 Common
4 Normally closed contacts (NC)
5 Normally open contacts (NO)
6 Combination: Normally open contacts and normally closed contacts (NO/NC)
7 1 kΩ EOL resistor (ICP-1K22AWG-10)
8 Brown
9 Black
10 Red
Point voltage parameters
Point voltage parameters are specified. Refer to Specifications, page 147.
Dual EOL resistor circuit style
Notice!
For the dual EOL resistor circuit style order ICP-1K22AWG-10, package of 10 1.0 kΩ EOL
resistors.
Point
COM
NC
1
4
3
2
Figure 12.2: Input wiring with dual EOL resistors
12.1.2
Control Panel On-board points | en 65
Bosch Security Systems, Inc. Installation and System Reference Guide 2016.05 | 14 | F.01U.287.180