Installation Manual
Table Of Contents
- Title Page
- Table of Contents
- Certifications, approvals, listings, and safety
- Introduction
- System overview
- Installation checklist
- Control panel installation
- Power supply
- Telephone communications
- IP communications
- Keypads, keyswitches, keyfobs and transmitters
- Keypads
- B915 Basic Keypad
- B920 Two-line Alphanumeric Keypad
- B921C Two-line Capacitive Keypad with Inputs
- B930 ATM Style Alphanumeric Keypad
- B942 Touch Screen Keypad
- Shortcuts and custom functions
- Address settings
- Supervision
- Installation and control panel wiring (keypads)
- Sensor loops overview and wiring (B921C/B942/B942W only)
- Output wiring (B942/B942W only)
- Troubleshooting
- Keyswitches
- RADION keyfobs and Inovonics pendant transmitters
- Keypads
- On-board outputs
- Off-board outputs
- On-board points
- Off-board points
- Wireless modules
- Access control
- Program and test the control panel
- Control panel board overview
- System wiring diagrams
- Approved applications
- Keypad Installer menu
- [1] Program menu
- [1] Reporting > [1] Phone menu parameters
- [1] Reporting > [2] Network menu parameters
- [1] Reporting > [3] Routing menu parameters
- [1] Reporting > [4] Personal Note menu parameters
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [1] Module Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [2] Address Parameters menu
- [2] Network > [1] Ethernet > (choose the bus module or on-board) > [3] DNS Parameters menu
- [2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in module)
- [3] RPS > [1] RPS Passcode menu parameters
- [3] RPS > [2] RPS Phone Number menu parameters
- [3] RPS > [3] RPS IP Address menu parameters
- [3] RPS > [4] RPS Port Number menu parameters
- [4] Area Options menu parameters
- [5] Keypad menu parameters
- [6] Users menu parameters
- [7] Points menu parameters
- [8] Disable Programming menu
- [2] Wireless menu
- [1] RF Point Menu> [1] Enroll Point RFID
- [1] RF Point Menu> [2] Replace Point RFID
- [1] RF Point Menu> [3] Remove Point RFID
- [2] RF Repeater Menu > [1] Add Repeater
- [2] RF Repeater Menu > [2] Replace Repeater
- [2] RF Repeater Menu > [3] Remove Repeater
- [3] RF Diagnostic Menu > [1] RF Points
- [3] RF Diagnostic Menu > [2] RF Repeater Menu
- [3] Diags menu
- [4] Serv Byp (Service Bypass) menu
- [5] Versions menu
- [6] Cloud menu
- [1] Program menu
- Specifications
- Appendix
- Back Page
7. Press [ENTER] while viewing the desired format to select it and save the programming.
8. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads configuration of Phone Format
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [1] Reporting > [1] Phone menu. The keypad shows the phone
number for the phone destination.
3. Use
/[PREV] or /[NEXT] to go to the destination you want to edit.
4. Press [Format] to view and edit the phone format, and then press [Edit] to edit the
phone format.
5. Press the icon or softkey for the desired format.
6. Press [Save] to save the programming.
7. When the keypad shows Parameter Saved, escape from the menu.
[1] Reporting > [2] Network menu parameters
Enhanced communications is the ability to communicate by some means other than a standard
digital dialer. The control panel can include four separate enhanced communication
destinations to which the control panel can route events. In this menu, you can enable
enhanced communication and edit the network address, network address, poll rate, and port
number for each destination (D1, D2, D3, and D4).
D1 Network address __________________________ Poll rate ___________ Port number _______
D2 Network address __________________________ Poll rate ___________ Port number _______
D3 Network address __________________________ Poll rate ___________ Port number _______
D4 Network address __________________________ Poll rate ___________ Port number _______
Enhanced Comm
B91x/B92x keypads configuration of Enhanced Comm
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [1] Reporting > [2] Network > [1] Enhanced Comm. The keypad
shows the Enhanced Comm option as well as the current default value.
3. Press [ENTER] to view and change the enhanced comm options.
4. Use [PREV] or [NEXT] to toggle between the Yes and No options.
5. Press [ENTER] while viewing the desired option to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads configuration of Enhanced Comm
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to [1] Program > [1] Reporting > [2] Network > [1] Enhanced Comm menu. The
keypad shows the Enhanced Comm option as well as the current default value.
3. Press [Enhanced Comm] to view and change the enhanced comm options, and then press
[Edit] to edit the enhanced communication option.
4. Press the icon or softkey for the desired option.
5. Press [Save] to save the programming.
6. When the keypad shows Parameter Saved, escape from the menu.
Network Address
20.1.2
110 en | Keypad Installer menu Control Panel