Owner`s manual

Central monitoring stations provide 24-hour system
monitoring with access to vital services. Professional
security personnel can test the system, monitor
system activity, and alert the police, fire department,
or other emergency response teams if necessary.
Functions
Programmable outputs
500 mA not to exceed 1.3 A total current for a
burglary system, or not to exceed 1.0 A total current
for household fire applications
800 mA auxiliary power at 12 VDC
Four alarm-output patterns
Programmable bell test
Three programmable outputs; one high current using
a relay, and two trigger outputs
Output A contact rating is 3 Amps
System response
High-performance micro-controller provides industry
leading system response
20 custom point indexes
Selectable point response time
Cross point capability
Fire alarm verification
Dangerous gas indicator includes carbon monoxide
(NFPA 720)
Watch mode
Scheduled events (SKEDs) perform several functions,
such as turn on (arm) the system, turn off (disarm)
the system, bypass and unbypass points, and control
relays
User interface
Supervision of up to 8 keypads
Custom keypad text is fully programmable through
RPS
Full function menu including custom functions
Authority by area and 32 character name for each
user
14 custom authority levels control user’s authority to
change, add, or delete passcodes to disarm or bypass
areas; and to start system tests
Programmable primary and secondary language by
user and keypad; select from English, Spanish,
French, and Portuguese
Area configurations
Area programming offers a wide selection of different
system configurations. Make area arming conditional
on other areas (master or associate), if desired. You
can configure any area for perimeter and interior
arming, not requiring a separate area for this function.
Link multiple areas to a shared area which is
automatically controlled (hallway or lobby). For higher
security applications, the Area Re-Arm feature
guarantees that areas are always rearmed, and are
disarmed for no longer than a specific, configurable,
amount of time (for example, service time).
Custom functions
For added convenience, the installer can program
custom functions that allow customers to complete
complex tasks with one simple action. For example, a
custom function can bypass a group of points and arm
the system, allowing the user to perform these
functions with one easy command. Users can activate
custom functions with a keypad, keyfob, token, or
card, or the control panel can activate a function in
reaction to a faulted point, or automatically through a
scheduled event (SKED).
Passcode security
Two-man rule. Requires two people with two unique
passcodes to be present at the time of opening.
Early ambush. Allows users to verify that the facility is
safe by requiring two passcodes. The control panel
sends a duress event if the user does not enter the
passcode a second time after inspecting the
premises.
Dual authentication. Requires two forms of
identification before processing certain system
commands, including turning off the system and
opening doors. A standard system user must have a
passcode, a credential (token or card), and
appropriate command authority permissions assigned
in the door and keypad’s assigned area.
Easy exit control
The control panel changes from one On (armed) state
to another without turning off (disarming) the system.
For example, if you change the state from Part On
(Perimeter Arm) to All On (Master Arm), the control
panel complies and reports the change. Easy Exit
Control reduces the number of keystrokes, simplifying
system operation.
Programmable passcode-controlled menu list
Passcode-controlled shortcuts provide users only with
the options and information pertinent to them,
simplifying system operation.
Flexible control
The system provides the flexibility to choose added
convenience or high security. For example, you can
restrict to a keypad's immediate local area turning on
(arming) and turning off (disarming) the system with a
passcode, even if the user has access to other areas.
This is particularly useful for high security areas,
where a user may have access to the area, but would
prefer to only turn off (disarm) the area individually
rather than with the rest of the system. Another option
is to program the system to turn off all areas the user
can access from any keypad.
Monitor Delay/Delayed Response
Create a special point index that delays the reaction of
a point for a specified time (up to 1 hour in minutes
and seconds). This delay provides time for the
specified condition to reset before activating any
annunciation. The system can annunciate locally and
send a report, if desired. When the system is armed,
2
| B5512 Control Panel