TCB4 Upgrade Kit for LBB 3500/00, /10 and /30 LBB 3500/00 and LBB 3500/10 LBB 3500/30 Security SecuritySystems Systems Installation Instruction en LBB 3519/20
Digital Congress Network | TCB 4 Upgrade Kit LBB 3519/20 | Chapter 1. Upgrade Kit LBB 3519/20 Chapter 1. Upgrade Kit LBB 3519/20 en | 3 LBB 3500/xx Introduction The upgrade kit LBB 3519/20 is intended for upgrading of the following DCN Central Control Units: • LBB 3500/00 (D) • LBB 3500/10 (D) • LBB 3500/30 (D) The upgrade kit LBB 3519/20 (Trunk Communication Board (TCB 4)) once installed in the Central Control Units provides the CCUs’ with a high speed serial RS 232 port.
Digital Congress Network | TCB 4 Upgrade Kit LBB 3519/20 | Chapter 1. Upgrade Kit LBB 3519/20 1.1 Before you Begin en | 4 Installation procedure 1. Remove the top-cover from the CCU. 2. Locate the TCB (version 2 or 3). For location of the TCB see Fig 1-1. NOTE: For Multi-CCUs type LBB 3500/30 carefully remove the ‘Multi-CCU’ card from the TCB card. The TCB is located under the ‘Multi-CCU’ card. 3. Remove all interconnection cables from the TCB. 4. Remove the 6 screws securing the TCB, 5. Remove the TCB.
Digital Congress Network | TCB 4 Upgrade Kit LBB 3519/20 | Chapter 1.
Digital Congress Network | TCB 4 Upgrade Kit LBB 3519/20 | Chapter 2. Trunk Communication Board (TCB4) DIP-switch S14 1 2 3 S14 7 6 5 4 3 2 1 ON 1 X14 15 Port 2 8 OFF ON 1 X17a X17b 3 S10 S10 Reset Switch IC1 X41 14 IC12 IC04 Port 1 X40 13 ON See Table 3.1 and 3-2 DIP-switch S9 IC11 X10 1 2 See Table 2.
Digital Congress Network | TCB 4 Upgrade Kit LBB 3519/20 | Chapter 2. Trunk Communication Board (TCB4) 2.4 S9 DIP-Switch settings 2.5 Jumper settings See fig. 2-1 for location, and Table 2.1 for functionality of the DIP-switches. See fig. 2-1 for location, and Table 2-2 for functionality of the jumpers. Table 2.1 : S9 DIP-switch settings Table 2.2 : Jumper settings ON* Chairman priority tone ON (default).
Digital Congress Network | TCB 4 Upgrade Kit LBB 3519/20 | Chapter 3. CCU Protocol and Serial Port settings Chapter 3. CCU Protocol and Serial Port settings For location of DIP-switches see fig. 2-1 3.1 LBB 3500/xx (TCB 4) - Port 1 : DCN Control PC Port 2 : Camera Control In a single (stand-alone) CCU systems two serial COM-ports (Port 1 and Port 2) are available. Both ports can be individually configured. Default settings are; • 8 data bits • No parity check • 1 Stop bit Table 3.
Digital Congress Network | TCB 4 Upgrade Kit LBB 3519/20 | Chapter 3.
For more information please visit www.boschsecuritysystems.com © 2003 Bosch Security Systems B.V.